On LiF:Mg,Cu,P and LiF:Mg,Ti phosphors high & ultra-high dose features

LiF:Mg,Ti and LiF:Mg,Cu,P are well known thermoluminescence (TL) dosimetry materials since many years. A few years ago their properties seemed well known and it was widely believed that they are not suitable for the measurement of doses above the saturation level of the TL signal, which for both materials occur at about 1 kGy. The high-dose high-temperature TL emission of LiF:Mg,Cu,P observed at the IFJ in 2006, which above 30 kGy takes the form of the so-called TL peak B, opened the way to use this material for measuring the dose in the high and ultra-high range, in particular for the monitoring of ionizing radiation around the essential electronic elements of high-energy accelerators, also fission and fusion facilities, as well as for emergency dosimetry. This discovery initiated studies of high and ultra-high dose characteristics of both of these phosphors, which turned out to be significantly different in many aspects. These studies not only strive to refine the method for measuring high doses based on the observed phenomenon, but also, and perhaps above all, bring us closer to understanding its origin and essence. This manuscript aims to review existing research data on the high and ultra-high dose features of both LiF based phosphors.

preprint2014arXivOpen access

Signal facts

What is known right now

Open access5 authors1 topic

Next steps

Decide what to do with this paper

Use like or dislike for the fast social read. The more specific scholarly feedback stays available below when needed.

Log in to curate

Reading frame

Keep the important context close to the paper

Keep the important signals around this paper in one place: votes, save state, collection context, reviews and the metadata you need before deciding what to do next.

Institutions

Add specific reaction

Move through the context

Research map

Open full explorer

Move through nearby people, institutions, topics and adjacent work without leaving the paper page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Structured reviews

0 review(s)

ContributeLeave structured feedbackUse the review template when you have a concrete strength, concern or method question.Open review form

No structured reviews yet. High-signal critique starts here.

Work discussion

0 comment(s)

DiscussAdd a high-signal commentKeep quick notes, caveats and replication pointers separate from formal reviews.Open comment form

No discussion yet. The first strong comment sets the tone.