Paper detail

Measuring high-precision luminosity at the CEPC

Purpose: Luminosity measurement at the Circular Electron-Positron Collider (CEPC) is required to achieve 10^-4 precision when operating at the center-of-mass energy of the Z-pole. Approximately 10^12 Z-bosons will be collected to refine measurements of Standard Model processes. The design of the luminosity calorimeter (LumiCal) takes into account the geometry of the Machine-Detector-Interface (MDI) for the detection of Bhabha events. The detector simulation with GEANT predicts measurements of scattered electrons, positrons, and radiation photons. Results: The luminosity measurement derived from Bhabha event counting relies on the low-θ fiducial edge with a mean of better than 1 μRad. Both the beam monitoring on the interaction point (IP) and the LumiCal Si-wafer positions shall be monitored to a mean of better than 1 μm. The beam-pipe design is optimized with a low-mass window of less than 2 mm thick Be window for calibration of multiple scattering. With Si-layers capable of 5 μm resolution, the error on the mean of fiducial edges is measured to 1 μm. The detector displacement requires survey monitoring to sub-micron precision. Conclusion: The scattered electrons at IP are measured with the LumiCal Si-wafers and high granularity of LYSO bars. The accompanying photon with larger opening angles can be identified and studied for radiative Bhabha events. The NLO calculations for the Bhabha interaction are achieving 10^-4. With the LumiCal design of silicon detectors and LYSO calorimeters, the precision is pursued for IP and detector positions being monitored, to achieve the goal of 10^-4 precision on luminosity measurement.

preprint2026arXivOpen access
0citations
0reviews
0saves
Nocode
Nodataset
0institutions

Next steps

Decide what to do with this paper

Use like or dislike for the fast social read. The more specific scholarly feedback stays available below when needed.

Log in to curate

Reading frame

Keep the important context close to the paper

Keep the important signals around this paper in one place: votes, save state, collection context, reviews and the metadata you need before deciding what to do next.

Add specific reaction

Move through the context

Research map

Open full explorer

Move through nearby people, institutions, topics and adjacent work without leaving the paper page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Structured reviews

0 review(s)

ContributeLeave structured feedbackUse the review template when you have a concrete strength, concern or method question.Open review form

No structured reviews yet. High-signal critique starts here.

Work discussion

0 comment(s)

DiscussAdd a high-signal commentKeep quick notes, caveats and replication pointers separate from formal reviews.Open comment form

No discussion yet. The first strong comment sets the tone.