Researcher profile

Ming Qi

Ming Qi contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
7works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2026arXiv

Measuring high-precision luminosity at the CEPC

Purpose: Luminosity measurement at the Circular Electron-Positron Collider (CEPC) is required to achieve 10^-4 precision when operating at the center-of-mass energy of the Z-pole. Approximately 10^12 Z-bosons will be collected to refine measurements of Standard Model processes. The design of the luminosity calorimeter (LumiCal) takes into account the geometry of the Machine-Detector-Interface (MDI) for the detection of Bhabha events. The detector simulation with GEANT predicts measurements of scattered electrons, positrons, and radiation photons. Results: The luminosity measurement derived from Bhabha event counting relies on the low-θ fiducial edge with a mean of better than 1 μRad. Both the beam monitoring on the interaction point (IP) and the LumiCal Si-wafer positions shall be monitored to a mean of better than 1 μm. The beam-pipe design is optimized with a low-mass window of less than 2 mm thick Be window for calibration of multiple scattering. With Si-layers capable of 5 μm resolution, the error on the mean of fiducial edges is measured to 1 μm. The detector displacement requires survey monitoring to sub-micron precision. Conclusion: The scattered electrons at IP are measured with the LumiCal Si-wafers and high granularity of LYSO bars. The accompanying photon with larger opening angles can be identified and studied for radiative Bhabha events. The NLO calculations for the Bhabha interaction are achieving 10^-4. With the LumiCal design of silicon detectors and LYSO calorimeters, the precision is pursued for IP and detector positions being monitored, to achieve the goal of 10^-4 precision on luminosity measurement.

preprint2026arXiv

Radiation Resistance of Ge-doped Multi-Mode Fiber for Optical Links in Collider Experiments

The applications of optical links in collider experiments provide the advantage of high-speed data transmission with low mass fibers over distances of a few hundred meters. Ge-doped multi-mode fibers are evaluated for radiation tolerance in ionizing doses of Co-60 gamma rays. The Radiation-Induced Attenuation (RIA) varies significantly depending on doping substances and fabrication technologies. A type of telecom-grade fiber has demonstrated an RIA of 0.05 dB/m under a total ionizing dose of 300 kGy(SiO2). The dependence on dose rate is compared in the range between 5 Gy/hr and 1.4 kGy/hr, and the annealing recovery is observed after the Co-60 source is shielded. The temperature dependence is investigated across a range of -15 oC to room temperature. At cold temperatures, stagnant annealing leads to a substantially higher RIA during irradiation. The recovery of radiation-induced defects is typically within a few hours, resulting in similar RIA levels regardless of the dose rate and temperature during exposure. Ge-doped fibers of chosen fabrication methods are capable of enduring high ionizing doses for use in high-energy physics experiments.

preprint2022arXiv

Mass Testing and Characterization of 20-inch PMTs for JUNO

Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least 3 % at 1 MeV, for which its instruments need to meet a certain quality and thus have to be fully characterized. More than 20,000 20-inch PMTs have been received and assessed by JUNO after a detailed testing program which began in 2017 and elapsed for about four years. Based on this mass characterization and a set of specific requirements, a good quality of all accepted PMTs could be ascertained. This paper presents the performed testing procedure with the designed testing systems as well as the statistical characteristics of all 20-inch PMTs intended to be used in the JUNO experiment, covering more than fifteen performance parameters including the photocathode uniformity. This constitutes the largest sample of 20-inch PMTs ever produced and studied in detail to date, i.e. 15,000 of the newly developed 20-inch MCP-PMTs from Northern Night Vision Technology Co. (NNVT) and 5,000 of dynode PMTs from Hamamatsu Photonics K. K.(HPK).

preprint2022arXiv

The Potential to Probe Solar Neutrino Physics with LiCl Water Solution

Lithium chloride water solution is a good option for solar neutrino detection. The $ν_e$ charged-current (CC) interaction cross-section on $\rm{{}^{7}Li}$ is evaluated with new B(GT) experimental measurements. The total CC interaction cross-section weighted by the solar $^8$B electron neutrino spectrum is $3.759\times10^{-42} \rm{cm}^2$, which is about 60 times that of the neutrino-electron elastic scattering process. The final state effective kinetic energy after the CC interaction on $\rm{{}^{7}Li}$ directly reflects the neutrino energy, which stands in sharp contrast to the plateau structure of recoil electrons of the elastic scattering. With the high solubility of LiCl of 74.5 g/100 g water at 10$^\circ$C and the high natural abundance of 92.41%, the molarity of $\rm{{}^{7}Li}$ in water can reach 11 mol/L for safe operation at room temperature. The CC event rate of $ν_e$ on $\rm{{}^{7}Li}$ in the LiCl water solution is comparable to that of neutrino-electron elastic scattering. In addition, the $ν_e$ CC interaction with the contained $\rm{{}^{37}Cl}$ also contributes a few percent of the total CC event rate. The contained $\rm{{}^{35}Cl}$ and $\rm{{}^{6}Li}$ also make a delay-coincidence detection for electron antineutrinos possible. The recrystallization method is found to be applicable for LiCl sample purification. The measured attenuation length of $11\pm1$ m at 430 nm shows that the LiCl solution is practicable for a 10-m diameter detector for solar neutrino detection. Clear advantages are found in studying the upturn effect of solar neutrino oscillation, light sterile neutrinos, and Earth matter effect. The sensitivities in discovering solar neutrino upturn and light sterile neutrinos are shown.

preprint2021arXiv

JUNO Physics and Detector

The Jiangmen Underground Neutrino Observatory (JUNO) is a 20 kton LS detector at 700-m underground. An excellent energy resolution and a large fiducial volume offer exciting opportunities for addressing many important topics in neutrino and astro-particle physics. With 6 years of data, the neutrino mass ordering can be determined at 3-4 sigma and three oscillation parameters can be measured to a precision of 0.6% or better by detecting reactor antineutrinos. With 10 years of data, DSNB could be observed at 3-sigma; a lower limit of the proton lifetime of 8.34e33 years (90% C.L.) can be set by searching for p->nu_bar K^+; detection of solar neutrinos would shed new light on the solar metallicity problem and examine the vacuum-matter transition region. A core-collapse supernova at 10 kpc would lead to ~5000 IBD and ~2000 (300) all-flavor neutrino-proton (electron) scattering events. Geo-neutrinos can be detected with a rate of ~400 events/year. We also summarize the final design of the JUNO detector and the key R&D achievements. All 20-inch PMTs have been tested. The average photon detection efficiency is 28.9% for the 15,000 MCP PMTs and 28.1% for the 5,000 dynode PMTs, higher than the JUNO requirement of 27%. Together with the >20 m attenuation length of LS, we expect a yield of 1345 p.e. per MeV and an effective energy resolution of 3.02%/\sqrt{E (MeV)}$ in simulations. The underwater electronics is designed to have a loss rate <0.5% in 6 years. With degassing membranes and a micro-bubble system, the radon concentration in the 35-kton water pool could be lowered to <10 mBq/m^3. Acrylic panels of radiopurity <0.5 ppt U/Th are produced. The 20-kton LS will be purified onsite. Singles in the fiducial volume can be controlled to ~10 Hz. The JUNO experiment also features a double calorimeter system with 25,600 3-inch PMTs, a LS testing facility OSIRIS, and a near detector TAO.

preprint2020arXiv

Feasibility and physics potential of detecting $^8$B solar neutrinos at JUNO

The Jiangmen Underground Neutrino Observatory~(JUNO) features a 20~kt multi-purpose underground liquid scintillator sphere as its main detector. Some of JUNO&#39;s features make it an excellent experiment for $^8$B solar neutrino measurements, such as its low-energy threshold, its high energy resolution compared to water Cherenkov detectors, and its much large target mass compared to previous liquid scintillator detectors. In this paper we present a comprehensive assessment of JUNO&#39;s potential for detecting $^8$B solar neutrinos via the neutrino-electron elastic scattering process. A reduced 2~MeV threshold on the recoil electron energy is found to be achievable assuming the intrinsic radioactive background $^{238}$U and $^{232}$Th in the liquid scintillator can be controlled to 10$^{-17}$~g/g. With ten years of data taking, about 60,000 signal and 30,000 background events are expected. This large sample will enable an examination of the distortion of the recoil electron spectrum that is dominated by the neutrino flavor transformation in the dense solar matter, which will shed new light on the tension between the measured electron spectra and the predictions of the standard three-flavor neutrino oscillation framework. If $Δm^{2}_{21}=4.8\times10^{-5}~(7.5\times10^{-5})$~eV$^{2}$, JUNO can provide evidence of neutrino oscillation in the Earth at the about 3$σ$~(2$σ$) level by measuring the non-zero signal rate variation with respect to the solar zenith angle. Moveover, JUNO can simultaneously measure $Δm^2_{21}$ using $^8$B solar neutrinos to a precision of 20\% or better depending on the central value and to sub-percent precision using reactor antineutrinos. A comparison of these two measurements from the same detector will help elucidate the current tension between the value of $Δm^2_{21}$ reported by solar neutrino experiments and the KamLAND experiment.

preprint2020arXiv

TAO Conceptual Design Report: A Precision Measurement of the Reactor Antineutrino Spectrum with Sub-percent Energy Resolution

The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future reactor neutrino experiments, and to provide a benchmark measurement to test nuclear databases. A spherical acrylic vessel containing 2.8 ton gadolinium-doped liquid scintillator will be viewed by 10 m^2 Silicon Photomultipliers (SiPMs) of >50% photon detection efficiency with almost full coverage. The photoelectron yield is about 4500 per MeV, an order higher than any existing large-scale liquid scintillator detectors. The detector operates at -50 degree C to lower the dark noise of SiPMs to an acceptable level. The detector will measure about 2000 reactor antineutrinos per day, and is designed to be well shielded from cosmogenic backgrounds and ambient radioactivities to have about 10% background-to-signal ratio. The experiment is expected to start operation in 2022.