Paper detail

Enhancing spatial resolution of soft x-ray CCD detectors by single-photon centroid determination

In Charge Coupled Device (CCD) detectors the electrons excited upon absorption of a single x-ray photon quickly diffuse and generate charge-spots often larger than pixel dimensions. In the soft x-ray range this phenomenon drastically limits the effective spatial resolution to approximately 25μm, irrespective of the pixel size. For very low fluence the charge-cloud centroid determination can be used, on each individual spot, to estimate the actual photon impact position with sub-pixel precision. The readout noise and speed, together with the charge and spatial undersampling, are the main factors limiting the accuracy of this procedure in commercial devices. We have developed and extensively tested an algorithm for efficient centroid reconstruction on images acquired by low noise detectors not designed for single photon counting. We have thus measured a position uncertainty of 6-7μm in CCDs with 13.5μm and 20.0μm pixel size, around 1 keV photon energy. We have analyzed the centroid calculation performances by modelling the spot generation process. We show how the resolution is affected by both random uncertainty, mainly ascribed to the readout noise, and systematic error, due to the undersampling of the charge spot. This study was motivated by the growing need of of high-resolution high-sensitivity 2D position sensitive detectors in resonant inelastic (soft) x-ray scattering (RIXS), an emergent synchrotron radiation based spectroscopy.

preprint2014arXivOpen access

Signal facts

What is known right now

Open access4 authors2 topics

Next steps

Decide what to do with this paper

Use like or dislike for the fast social read. The more specific scholarly feedback stays available below when needed.

Log in to curate

Reading frame

Keep the important context close to the paper

Keep the important signals around this paper in one place: votes, save state, collection context, reviews and the metadata you need before deciding what to do next.

Institutions

Add specific reaction

Move through the context

Research map

Open full explorer

Move through nearby people, institutions, topics and adjacent work without leaving the paper page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Structured reviews

0 review(s)

ContributeLeave structured feedbackUse the review template when you have a concrete strength, concern or method question.Open review form

No structured reviews yet. High-signal critique starts here.

Work discussion

0 comment(s)

DiscussAdd a high-signal commentKeep quick notes, caveats and replication pointers separate from formal reviews.Open comment form

No discussion yet. The first strong comment sets the tone.