Construction and Measurements of an Improved Vacuum-Swing-Adsorption Radon-Mitigation System

preprint2015arXivOpen access

Abstract

In order to reduce backgrounds from radon-daughter plate-out onto detector surfaces, an ultra-low-radon cleanroom is being commissioned at the South Dakota School of Mines and Technology. An improved vacuum-swing-adsorption radon mitigation system and cleanroom build upon a previous design implemented at Syracuse University that achieved radon levels of ∼\sim0.2 \,Bq \,m−3^{-3}. This improved system will employ a better pump and larger carbon beds feeding a redesigned cleanroom with an internal HVAC unit and aged water for humidification. With the rebuilt (original) radon mitigation system, the new low-radon cleanroom has already achieved a >> \,300×\times reduction from an input activity of 58.6±0.758.6\pm0.7 \,Bq \,m−3^{-3} to a cleanroom activity of 0.13±0.060.13\pm0.06 \,Bq \,m−3^{-3}.

Explore this paper’s authors, topics and related work.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Reviews 0

Write a reviewWrite

No reviews yet.

Discussion 0

Add a commentWrite

No comments yet.