Abstract
The Muon Telescope is a muography experiment for imaging volcanoes in Colombia. It consists of a scintillator tracking system and a water Cherenkov detector used for particle deposited energy measurement. The MuTe operates autonomously in high altitude environments where the temperature gradient reaches up to C. In this work, we characterize the breakdown voltage, gain, and noise of the telescope silicon photomultipliers for temperature variations spanning to C. We demonstrated that the discrimination threshold for the MuTe hodoscope must be above 5 pe to avoid contamination due to the SiPM dark count, crosstalk, and afterpulsing. We also assess the MuTe counting rate depending on day-night temperature variations.