We measured the anomalous-Nernst effect and anisotropic magnetoresistive heating in a lateral multiterminal Permalloy/Copper spin valve using all-electrical lock-in measurements. To interpret the results, a three-dimensional thermoelectric finite-element-model is developed. Using this model, we extract the heat profile which we use to determine the anomalous Nernst coefficient of Permalloy Rn=0.13 and also determine the maximum angle of theta=8 degrees of the magnetization prior to the switching process when an opposing non-collinear 10 magnetic field is applied.