A 2.5 μμW 30 nV/√\surdHz Instrumentation Amplifier for Bioimpedance Sensors with Source Degenerated Current Mirror and DTMOS Transistor

preprint2026arXivOpen access

Abstract

This paper proposes a low-power and low-noise instrumentation amplifier (IA) tailored for bioimpedance sensing applications. The design originates from a gain-boosted flipped voltage follower (FVF) transconductance (TC) stage and integrates two complementary circuit techniques to improve the noise performance. To achieve an optimal balance between input-referred noise and available voltage headroom, a source-degenerated current mirror (SDCM) is adopted, resulting in reducing the input-referred noise by 7.95% compared with a conventional current mirror structure. In addition, a dynamic threshold MOSFET (DTMOS) scheme is employed to enhance the effective transconductance, leading to a further 11.66% reduction in input-referred noise. Simulated in a 28 nm CMOS process demonstrate that the proposed IA achieves an input-referred noise floor of 30 nV/√\surdHz and a bandwidth of 1.44 MHz, while consuming only 2.5 μμW from a 0.8 V supply. Compared to the baseline design, the proposed approach achieves a 32.4% reduction in power consumption without degrading noise performance. The complete design parameters are open-sourced in this paper, to ensure reproducibility and facilitate future developments.

Explore this paper’s authors, topics and related work.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Reviews 0

Write a reviewWrite

No reviews yet.

Discussion 0

Add a commentWrite

No comments yet.