Source author record

Zongsheng Zheng

Zongsheng Zheng appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Active noise control techniques for nonlinear systems

Most of the literature focuses on the development of the linear active noise control (ANC) techniques. However, ANC systems might have to deal with some nonlinear components and the performance of linear ANC techniques may degrade in this scenario. To overcome this limitation, nonlinear ANC (NLANC) algorithms were developed. In Part II, we review the development of NLANC algorithms during the last decade. The contributions of heuristic ANC algorithms are outlined. Moreover, we emphasize recent advances of NLANC algorithms, such as spline ANC algorithms, kernel adaptive filters, and nonlinear distributed ANC algorithms. Then, we present recent applications of ANC technique including linear and nonlinear perspectives. Future research challenges regarding ANC techniques are also discussed.

preprint2020arXiv

Real-time LCC-HVDC Maximum Emergency Power Capacity Estimation Based on Local PMU Measurements

The adjustable capacity of a line-commutated-converter High Voltage Direct Current (LCC-HVDC) connected to a power system, called the LCC-HVDC maximum emergency power capability or HVDC-MC for short, plays an important role in determining the response of that system to a large disturbance. However, it is a challenging task to obtain an accurate HVDC-MC due to system model uncertainties as well as to contingencies. To address this problem, this paper proposes to estimate the HVDC-MC using a Thevenin equivalent (TE) of the system seen at the HVDC terminal bus of connection with the power system, whose parameters are estimated by processing positive-sequences voltages and currents of local synchrophasor measurements. The impacts of TE potential changes on the impedance estimation under large disturbance have been extensively investigated and an adaptive screening process of current measurements is developed to reduce the error of TE impedance estimation. The uncertainties of phasor measurements have been further taken into account by resorting to the total least square estimation method. The limitations of the HVDC control characteristics, the voltage-dependent current order limit, the converter capacity, and the AC voltage on HVDC-MC estimation are also considered. The simulations show that the proposed method can accurately track the dynamics of the TE parameters and the real-time HVDC-MC after the large disturbances.