Researcher profile

Zhuo Deng

Zhuo Deng contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

RFormer: Transformer-based Generative Adversarial Network for Real Fundus Image Restoration on A New Clinical Benchmark

Ophthalmologists have used fundus images to screen and diagnose eye diseases. However, different equipments and ophthalmologists pose large variations to the quality of fundus images. Low-quality (LQ) degraded fundus images easily lead to uncertainty in clinical screening and generally increase the risk of misdiagnosis. Thus, real fundus image restoration is worth studying. Unfortunately, real clinical benchmark has not been explored for this task so far. In this paper, we investigate the real clinical fundus image restoration problem. Firstly, We establish a clinical dataset, Real Fundus (RF), including 120 low- and high-quality (HQ) image pairs. Then we propose a novel Transformer-based Generative Adversarial Network (RFormer) to restore the real degradation of clinical fundus images. The key component in our network is the Window-based Self-Attention Block (WSAB) which captures non-local self-similarity and long-range dependencies. To produce more visually pleasant results, a Transformer-based discriminator is introduced. Extensive experiments on our clinical benchmark show that the proposed RFormer significantly outperforms the state-of-the-art (SOTA) methods. In addition, experiments of downstream tasks such as vessel segmentation and optic disc/cup detection demonstrate that our proposed RFormer benefits clinical fundus image analysis and applications. The dataset, code, and models are publicly available at https://github.com/dengzhuo-AI/Real-Fundus

preprint2019arXiv

Deep levels analysis in wavelength extended InGaAsBi photodetector

InP based dilute Bismide InGaAsBi material is emerging as a promising candidate for extending short wavelength infrared detection. One critical factor to limit the performance of these InGaAsBi photodiodes is dark current caused by defects within the material. In this work, low frequency noise spectroscopy (LFNS) and temperature varied photoluminescence was used to characterize the defect levels in the devices. Three deep levels located at Ec -0.33 eV, Ev +0.14 eV, and Ec -0.51 eV were identified from the LFNS spectra, which are consistent with emission peak energy found by photoluminescence spectra of InGaAsBi.

preprint2019arXiv

High Speed Mid-Infrared Interband Cascade Photodetector Based on InAs/GaSb Type-II Superlattice

High speed mid-wave infrared (MWIR) photodetectors have applications in the areas such as free space optical communication and frequency comb spectroscopy. However, most of the research on the MWIR photodetectors is focused on how to increase the quantum efficiency and reduce the dark current, in order to improve the detectivity (D*), and the 3dB bandwidth performance of the corresponding MWIR photodetectors is still not fully studied. In this work, we report and characterize a MWIR interband cascade photodetector based on InAs/GaSb type-II superlattice with a 50% cutoff wavelength at ~5.3 um at 300 K. The 3 dB cutoff frequency is 2.4 GHz at 300 K, for a 40 μm circular diameter device under -5 V applied bias. Limitations on the detector high speed performance are also discussed.High speed mid-wave infrared (MWIR) photodetectors have applications in the areas such as free space optical communication and frequency comb spectroscopy. However, most of the research on the MWIR photodetectors is focused on how to increase the quantum efficiency and reduce the dark current, in order to improve the detectivity (D*), and the 3dB bandwidth performance of the corresponding MWIR photodetectors is still not fully studied. In this work, we report and characterize a MWIR interband cascade photodetector based on InAs/GaSb type-II superlattice with a 50% cutoff wavelength at ~5.3 um at 300 K. The 3 dB cutoff frequency is 2.4 GHz at 300 K, for a 40 um circular diameter device under -5 V applied bias. Limitations on the detector high speed performance are also discussed.