Source author record

Zhiqin Chu

Zhiqin Chu appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2026arXiv

Nanodiamond-Enabled Torsion Microscopy Uncovers Multidimensional Cell-Matrix Mechanical Interactions

Traditional cellular force-sensing techniques, such as traction force microscopy (TFM), are predominantly limited to measuring linear tractions, overlooking and technically unable to capture the nanoscale torsional forces that are critical in cell-matrix interactions. Here, we introduce a nanodiamond-enabled torsion microscopy (DTM) that integrates nitrogen-vacancy (NV) centers as orientation markers with micropillar arrays to decouple and quantify nanoscale rotational and translational motions induced by cells. This approach achieves high precision (~1.47 degree rotational accuracy and ~3.13*10-15 Nm torque sensitivity), enabling reconstruction of cellular torsional force fields and twisting energy distributions previously underestimated. Our findings reveal the widespread presence of torsional forces in cell-matrix interactions, introducing "cellular mechanical modes" where different adhesion patterns dictate the balance between traction- and torque- mediated mechanical energy transferred to the substrate. Notably, in immune cells like macrophages that generally exert low linear tractions, torque overwhelmingly dominates traction, highlighting a unique mechanical output for specific cellular functions. By uncovering these differential modes, DTM provides a versatile tool to advance biomechanical investigations, with potential applications in disease diagnostics and therapeutics.

preprint2022arXiv

Super-resolution multicolor fluorescence microscopy enabled by an apochromatic super-oscillatory lens with extended depth-of-focus

Multicolor super-resolution imaging remains an intractable challenge for both far-field and near-field based super-resolution techniques. Planar super-oscillatory lens (SOL), a far-field subwavelength-focusing diffractive lens device, holds great potential for achieving sub-diffraction-limit imaging at multiple wavelengths. However, conventional SOL devices suffer from a numerical aperture (NA) related intrinsic tradeoff among the depth of focus (DoF), chromatic dispersion and focus spot size, being an essential characteristics of common diffractive optical elements. Typically, the limited DoF and significant chromatism associated with high NA can lead to unfavorable degradation of image quality although increasing NA imporves the resolution. Here, we apply a multi-objective genetic algorithm (GA) optimization approach to design an apochromatic binary-phase SOL that generates axially jointed multifoci concurrently having prolonged DoF, customized working distance (WD) and suppressed side-lobes yet minimized main-lobe size, optimizing the aforementioned NA-dependent tradeoff. Experimental implementation of this GA-optimized SOL demonstrates simultaneous focusing of blue, green and red light beams into an optical needle half of the incident wavelength in diameter at 428 um WD, resulting in an ultimate resolution better than one third of the incident wavelength in the lateral dimension. By integrating this apochromatic SOL device with a commercial fluorescence microscope, we employ the optical needle to perform, for the first time, three-dimensional super-resolution multicolor fluorescence imaging of the unseen fine structure of neurons at one go. The present study provides not only a practical route to far-field multicolor super-resolution imaging but also a viable approach for constructing imaging systems avoiding complex sample positioning and unfavorable photobleaching.