Researcher profile

Zhifeng Zhang

Zhifeng Zhang contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2016arXiv

Deformability-based circulating tumor cell separation with conical-shaped microfilters: concept, optimization and design criteria

The ability of detecting and separating CTCs can play a key role in early cancer detection and treatment. In recent years, there has been growing interest in using deformability-based CTC separation microfilters due to their simplicity and low cost. Most of previous studies in this area are mainly based on experimental work. Although experimental research provides useful insights in designing CTC separation devices, there is still a lack of design guidelines based on fundamental understandings of the cell separation process in the filers. While experimental efforts face challenges especially microfabrication difficulties, we adopt numerical simulation here to study conical-shaped microfilters using deformability difference between CTCs and blood cells for separation process. We use liquid drop model for modeling a CTC passing through such microfilters. The accuracy of the model in predicting the pressure signature of the system is validated by comparing with previous experiments. Pressure-deformability analysis of the cell going through the channel is then carried out in detail in order to better understand how a CTC behaves throughout the filtration process. Different system design criteria such as system throughput and unclogging of the system are discussed. Specifically, pressure behavior under different system throughput is analyzed. Regarding the unclogging issue, we define pressure ratio as a key parameter representing the ability to overcome clogging in such CTC separation devices and investigate the effect of conical angle on the optimum pressure ratio. Finally, the effect of unclogging applied pressure on the system performance is examined. Our study provides detailed understandings of the cell separation process and its characteristics, which can be used for developing more efficient CTC separation devices.

preprint2016arXiv

Entry effects of droplet in a micro confinement: implications for deformation-based CTC microfiltration

Deformation based circulating tumor cell (CTC) microchips are a representative diagnostic device for early cancer detection. This type of device usually involves a process of CTC trapping in a confined microgeometry. Further understanding of the CTC flow regime, as well as the threshold passing-through pressure is key to the design of deformation based CTC filtration devices. In the present numerical study, we investigate the transitional deformation and pressure signature from surface tension dominated flow to viscous shear stress dominated flow using a droplet model. Regarding whether CTC fully blocks the channel inlet, we observe two flow regimes: CTC squeezing and shearing regime. By studying the relation of CTC deformation at the exact critical pressure point for increasing inlet velocity, three different types of cell deformation are observed: 1) hemispherical front, 2) parabolic front, and 3) elongated CTC co-flowing with carrier media. Focusing on the circular channel, we observe a first increasing and then decreasing critical pressure change with increasing flow rate. By pressure analysis, the concept of optimum velocity is proposed to explain the behavior of CTC filtration and design optimization of CTC filter. Similar behavior is also observed in channels with symmetrical cross sessions like square and triangular but not in rectangular channels which only results in decreasing critical pressure.

preprint2013arXiv

Phase Diagram and Magnetic Excitations of Anisotropic Spin-One Magnets

We use a generalized spin wave approach and large scale quantum Monte Carlo (QMC) simulations to study the quantum phase diagram and quasiparticle excitations of the S=1 Heisenberg model with an easy-plane single-ion anisotropy in dimensions d=2 and 3. We consider two alternative approximations for describing the quantum paramagnetic state: the standard Holstein-Primakoff approximation and a modified treatment in which the local constraint (finite dimension of the local Hilbert space) is enforced by introducing a Lagrange multiplier. While both approximations produce qualitatively similar results, the latter approach is the only one that is in good quantitative agreement with the quantum phase diagram and the quasiparticle dispersions obtained with QMC. This result is very important for low-temperature studies of quantum paramagnets in magnetic fields because it shows that a simple modification of the standard analytical approach should produce much better quantitative agreement between theory and experiment.