Researcher profile

Zhang Jian

Zhang Jian contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - Baseline
3works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2013arXiv

Beam test of a one-dimensional position sensitive chamber on synchrotron radiation

One-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO2 has been accomplished at 1W2B laboratory of Beijing Synchrotron Radiation Source. The data of beam test were analyzed and some diffraction angles were obtained. The experimental results were in good agreement with standard data from ICDD powder diffraction file. The precision of diffraction angles was 1% to 4.7%. Most of relative errors between measured values of diffraction angles and existing data were less than 1%. As for the detector, the best position resolution in the test was 138 um (sigma value) with an X-ray tube. Finally, discussions of the results were given. The major factor that affected the precision of measurement was deviation from the flat structure of detector. The effect was analyzed and it came to a conclusion that it would be the optimal measurement scheme when the distance between the powder sample and detector was from 400 mm to 600 mm.

preprint2013arXiv

Study on the imaging ability of the 2D neutron detector based on MWPC

A 2D neutron detector based on 3He convertor and MWPC with an active area of 200 mm \times 200 mm has been successfully designed and fabricated. The detector has been tested with Am/Be neutron source and with collimated neutron beam with wavelength of λ = 1.37 Å. A best spatial resolution of 1.18 mm (FWHM) and good linearity were obtained. This is in good agreement with the theoretical calculations.

preprint2012arXiv

The Reconstruction Algorithm Study of 2D Interpolating Resistive Readout Structure

Systematic investigations including both simulation and prototype tests have been done about the interpolating resistive readout structure with GEM (Gaseous Electron Multiplier) detector. From the simulation, we have a good knowledge of the process of charges diffusion on the surface of the readout plane and develop several reconstruction methods to determine the hit position. The total signal duration time of a typical event with the readout structure is about several hundred nanoseconds, which implied an ideal count rate up to 106Hz. A stable worked prototype was designed and fabricated after the simulation. Using 55Fe 5.9keV X-Ray, the image performance of the prototype is examined with flat field image and some special geometry shapes, meanwhile, an energy resolution of about 17% is obtained.