Researcher profile

Zeyu Mao

Zeyu Mao contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2021arXiv

Integration of Renewable Generators in Synthetic Electric Grids for Dynamic Analysis

This paper presents a method to better integrate dynamic models for renewable resources into synthetic electric grids. An automated dynamic models assignment process is proposed for wind and solar generators. A realistic composition ratio for different types of wind turbine generators (WTG) is assigned to each wind generator. Statistics summarized from real electric grid data form the bases in assigning proper models with reasonable parameters to each WTG. A similar process is used to assign appropriate models and parameters to each photovoltaic (PV) generator. Multiple control strategies of the renewable resources are considered and tested in case studies. Two large-scale synthetic network test cases are used as examples of modeling the dynamics of renewable generators. Several transient stability metrics are adopted to assess the stability level after being subject to N-1 contingency event. Representative contingency events are given to demonstrate the performance of the synthetic renewable generator models.

preprint2021arXiv

Man-in-The-Middle Attacks and Defense in a Power System Cyber-Physical Testbed

Man-in-The-Middle (MiTM) attacks present numerous threats to a smart grid. In a MiTM attack, an intruder embeds itself within a conversation between two devices to either eavesdrop or impersonate one of the devices, making it appear to be a normal exchange of information. Thus, the intruder can perform false data injection (FDI) and false command injection (FCI) attacks that can compromise power system operations, such as state estimation, economic dispatch, and automatic generation control (AGC). Very few researchers have focused on MiTM methods that are difficult to detect within a smart grid. To address this, we are designing and implementing multi-stage MiTM intrusions in an emulation-based cyber-physical power system testbed against a large-scale synthetic grid model to demonstrate how such attacks can cause physical contingencies such as misguided operation and false measurements. MiTM intrusions create FCI, FDI, and replay attacks in this synthetic power grid. This work enables stakeholders to defend against these stealthy attacks, and we present detection mechanisms that are developed using multiple alerts from intrusion detection systems and network monitoring tools. Our contribution will enable other smart grid security researchers and industry to develop further detection mechanisms for inconspicuous MiTM attacks.

preprint2021arXiv

Multi-Source Data Fusion for Cyberattack Detection in Power Systems

Cyberattacks can cause a severe impact on power systems unless detected early. However, accurate and timely detection in critical infrastructure systems presents challenges, e.g., due to zero-day vulnerability exploitations and the cyber-physical nature of the system coupled with the need for high reliability and resilience of the physical system. Conventional rule-based and anomaly-based intrusion detection system (IDS) tools are insufficient for detecting zero-day cyber intrusions in the industrial control system (ICS) networks. Hence, in this work, we show that fusing information from multiple data sources can help identify cyber-induced incidents and reduce false positives. Specifically, we present how to recognize and address the barriers that can prevent the accurate use of multiple data sources for fusion-based detection. We perform multi-source data fusion for training IDS in a cyber-physical power system testbed where we collect cyber and physical side data from multiple sensors emulating real-world data sources that would be found in a utility and synthesizes these into features for algorithms to detect intrusions. Results are presented using the proposed data fusion application to infer False Data and Command injection-based Man-in- The-Middle (MiTM) attacks. Post collection, the data fusion application uses time-synchronized merge and extracts features followed by pre-processing such as imputation and encoding before training supervised, semi-supervised, and unsupervised learning models to evaluate the performance of the IDS. A major finding is the improvement of detection accuracy by fusion of features from cyber, security, and physical domains. Additionally, we observed the co-training technique performs at par with supervised learning methods when fed with our features.

preprint2021arXiv

Statistics for Building Synthetic Power System Cyber Models

A realistic communication system model is critical in power system studies emphasizing the cyber and physical intercoupling. In this paper, we provide characteristics that could be used in modeling the underlying cyber network for power grid models. A real utility communication network and a simplified inter-substation connectivity model are studied, and their statistics could be used to fulfill the requirements for different modeling resolutions.

preprint2020arXiv

Design and Evaluation of A Cyber-Physical Resilient Power System Testbed

A power system is a complex cyber-physical system whose security is critical to its function. A major challenge is to model and analyze its communication pathways with respect to cyber threats. To achieve this, the design and evaluation of a cyber-physical power system (CPPS) testbed called Resilient Energy Systems Lab (RESLab) is presented that captures realistic cyber, physical, and protection system features. RESLab is architected to be a fundamental tool for studying and improving the resilience of complex CPPS to cyber threats. The cyber network is emulated using Common Open Research Emulator (CORE) that acts as a gateway for the physical and protection devices to communicate. The physical grid is simulated in the dynamic time frame using PowerWorld Dynamic Studio (PWDS). The protection components are modeled with both PWDS and physical devices including the SEL Real-Time Automation Controller (RTAC). Distributed Network Protocol 3 (DNP3) is used to monitor and control the grid. Then, exemplifying the design and validation of these tools, this paper presents four case studies on cyber-attack and defense using RESLab, where we demonstrate false data and command injection using Man-in-the-Middle and Denial of Service attacks and validate them on a large-scale synthetic electric grid.

preprint2020arXiv

Generalized Contingency Analysis Based on Graph Theory and Line Outage Distribution Factor

Identifying the multiple critical components in power systems whose absence together has severe impact on system performance is a crucial problem for power systems known as (N-x) contingency analysis. However, the inherent combinatorial feature of the N-x contingency analysis problem incurs by the increase of x in the (N-x) term, making the problem intractable for even relatively small test systems. We present a new framework for identifying the N-x contingencies that captures both topology and physics of the network. Graph theory provides many ways to measure power grid graphs, i.e. buses as nodes and lines as edges, allowing researchers to characterize system structure and optimize algorithms. This paper proposes a scalable approach based on the group betweenness centrality (GBC) concept that measures the impact of multiple components in the electric power grid as well as line outage distribution factors (LODFs) that find the lines whose loss has the highest impact on the power flow in the network. The proposed approach is a quick and efficient solution for identifying the most critical lines in power networks. The proposed approach is validated using various test cases, and results show that the proposed approach is able to quickly identify multiple contingencies that result in violations.

preprint2020arXiv

The role of Hume-Rothery's rules play in the MAX phases formability

MAX phases are a family of layered, hexagonal-structure ternary carbides or nitrides of a transitional metal and an A-group element. What makes this type of material fascinating and potentially useful is their remarkable combinations of metallic and ceramic characteristics; as well as the indispensable role in 'top-down' synthesis of their 2D counterparts, MXenes. To enhance the efficiency in the successful search for potential novel MAX phases, the main efforts could go toward creating an informationprediction system incorporating all MAX phases' databases, as well as generally valid principles and the high-quality regularities. In this work, we employ structure mapping methodology, which has shown its merit of being useful guides in materials design, with Hume-Rothery parameters to provide guiding principles in the search of novel MAX phases. The formable/non-formable data on MAX phases can be ordered within a twodimensional plot by using proposed expression of geometrical and electron concentration factors.