Source author record

Ze-Hao Wang

Ze-Hao Wang appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Unbalanced-basis-misalignment tolerant measurement-device-independent quantum key distribution

Measurement-device-independent quantum key distribution (MDIQKD) is a revolutionary protocol since it is physically immune to all attacks on the detection side. However, the protocol still keeps the strict assumptions on the source side that the four BB84-states must be perfectly prepared to ensure security. Some protocols release part of the assumptions in the encoding system to keep the practical security, but the performance would be dramatically reduced. In this work, we present a MDIQKD protocol that requires less knowledge of encoding system to combat the troublesome modulation errors and fluctuations. We have also experimentally demonstrated the protocol. The result indicates the high-performance and good security for its practical applications. Besides, its robustness and flexibility exhibit a good value for complex scenarios such as the QKD networks.

preprint2021arXiv

High resolution imaging with anomalous saturated excitation

The nonlinear fluorescence emission has been widely applied for the high spatial resolution optical imaging. Here, we studied the fluorescence anomalous saturating effect of the nitrogen vacancy defect in diamond. The fluorescence reduction was observed with high power laser excitation. It increased the nonlinearity of the fluorescence emission, and changed the spatial frequency distribution of the fluorescence image. We used a differential excitation protocol to extract the high spatial frequency information. By modulating the excitation laser's power, the spatial resolution of imaging was improved approximate 1.6 times in comparison with the confocal microscopy. Due to the simplicity of the experimental setup and data processing, we expect this method can be used for improving the spatial resolution of sensing and biological labeling with the defects in solids.