Source author record

Yu-Ting Lin

Yu-Ting Lin appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
9topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2015arXiv

The Modeling and Quantification of Rhythmic to Non-rhythmic Phenomenon in Electrocardiography during Anesthesia

Variations of instantaneous heart rate appears regularly oscillatory in deeper levels of anesthesia and less regular in lighter levels of anesthesia. It is impossible to observe this "rhythmic-to-non-rhythmic" phenomenon from raw electrocardiography waveform in current standard anesthesia monitors. To explore the possible clinical value, I proposed the adaptive harmonic model, which fits the descriptive property in physiology, and provides adequate mathematical conditions for the quantification. Based on the adaptive harmonic model, multitaper Synchrosqueezing transform was used to provide time-varying power spectrum, which facilitates to compute the quantitative index: "Non-rhythmic-to-Rhythmic Ratio" index (NRR index). I then used a clinical database to analyze the behavior of NRR index and compare it with other standard indices of anesthetic depth. The positive statistical results suggest that NRR index provides addition clinical information regarding motor reaction, which aligns with current standard tools. Furthermore, the ability to indicates the noxious stimulation is an additional finding. Lastly, I have proposed an real-time interpolation scheme to contribute my study further as a clinical application.

preprint2015arXiv

When interpolation-induced reflection artifact meets time-frequency analysis

While extracting the temporal dynamical features based on the time-frequency analyses, like the reassignment and synchrosqueezing transform, attracts more and more interest in bio-medical data analysis, we should be careful about artifacts generated by interpolation schemes, in particular when the sampling rate is not significantly higher than the frequency of the oscillatory component we are interested in. In this study, we formulate the problem called the reflection effect and provide a theoretical justification of the statement. We also show examples in the anesthetic depth analysis with clear but undesirable artifacts. The results show that the artifact associated with the reflection effect exists not only theoretically but practically. Its influence is pronounced when we apply the time-frequency analyses to extract the time-varying dynamics hidden inside the signal. In conclusion, we have to carefully deal with the artifact associated with the reflection effect by choosing a proper interpolation scheme.

preprint2014arXiv

Real-time dynamics acquisition from irregular samples -- with application to anesthesia evaluation

The first objective of this paper is to introduce a unified approach to the D/A conversion, a real-time algorithm referred to as {\it blending operator}, based on spline functions of arbitrarily desired order, to interpolate the irregular data samples, while preserving all polynomials of the same spline order, with assured maximum order of approximation. This helps remove the two main obstacles for adapting the recently proposed time-frequency analysis technique {\it Synchrosqueezing transform} (SST) to irregular data samples in order to allow online computation. Secondly, for real-time dynamic information extraction from an oscillatory signal via SST, a family of vanishing-moment and minimum-supported spline-wavelets (to be called VM wavelets) are introduced for on-line computation of the CWT and its derivative. The second objective of this paper is to apply the proposed real-time algorithm and VM wavelets to clinical applications, particularly to the study of the "anesthetic depth" of a patient during surgery, with emphasis on analyzing two dynamic quantities: the "instantaneous frequencies" and the "non-rhythmic to rhythmic ratios" of the patient's respiration, based on a one-lead electrocardiogram (ECG) signal.It is envisioned that the proposed algorithm and VM wavelets should enable real-time monitoring of "anesthetic depth", during surgery, from the respiration signal via ECG measurement.

preprint2011arXiv

Voltage-induced defect mode interaction in a one-dimensional photonic crystal with a twisted-nematic defect layer

Defect modes are investigated in a band gap of an electrically tunable one-dimensional photonic crystal infiltrated with a twisted-nematic liquid crystal (1D PC/TN). Their frequency shift and interference under applied voltage are studied both experimentally and theoretically. We deal with the case where the defect layer thickness is much larger than the wavelength (Mauguin condition). It is shown theoretically that the defect modes could have a complex structure with the elliptic polarization. Two series of polarized modes interact with each other and exhibit an avoided crossing phenomenon in the case of opposite parity.