Source author record

Yu. B. Ovchinnikov

Yu. B. Ovchinnikov appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
3topics
2close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2012arXiv

Massive liquid Ar and Xe detectors for direct Dark Matter searches

A novel experiment for direct searches of the Dark Matter with liquid argon double-phase chamber with a mass of liquid Ar up to several hundred tons is proposed. To suppress the b-, g- and n0- backgrounds, the comparison of scintillation and ionization signals for every event is suggested. The addition in liquid Ar of photosensitive Ge(CH3)4 or C2H4 and suppression of triplet component of scintillation signals ensures the detection of scintillation signals with high efficiency and provides a complete suppression of the electron background. For the detection of photoelectrons and ionization electrons, highly stable and reliable GEM detectors must be used.

preprint2010arXiv

A multi-channel wire gas electron multiplier

A novel and relatively simple method of production of electrodes for a multi-channel wire gas multiplier is developed. Two modifications of the multipliers have been tested: with a multiplication of electrons between two wire electrodes, MWGEM, and between a wire electrode and continuous anode, MWCAT. For both MWGEM and MWCAT detectors, filled with neon under pressure of 760 Torr and irradiated by beta-particles (Ni-63), the coefficient of proportional multiplication of electrons up to 10000 was obtained. For the MWGEM detector irradiated by alpha-particles (Pu-239), the coefficient of proportional multiplication of 300 was obtained. It is observed, that in contrast to the GEM detectors, produced by perforation of a metal-clad plastic foil, in a MWGEM the discharges do not destroy its electrodes even for the potentials above the threshold of discharges. The results on operation of the MWCAT filled with Ar, Ar+CH4 and Ar+1% Xe are also presented.

preprint2010arXiv

Gas Electron Multiplier detectors with high reliability and stability

The Gas Electron Multiplier detectors with wire and metallic electrodes, with a gas filling in the gap between them were proposed and tested. The main advantage of these Gas Electron Multipliers compared to standard ones consists in their increased stability and reliability. The experimental results on testing of such detectors with gaps between the electrodes of 1 and 3 mm are reported. It is demonstrated, that the best gas filling for the gas electron multipliers is neon with small admixture of quenching gases (for example, (N2+H2O) at ~100ppm). This filling offers the greatest coefficient of proportional multiplication as compared with other gases, at small electric potential difference between the GEM electrodes, in absence of streamer discharges in the proportional region. The results on operation of the multi-channel gas electron multiplier with wire cathode and continuous anode filled with Ne, Ar, Ar+CH4 and Ar+1%Xe are presented also. Based on the experimental observations, the explanation of the mechanism of formation of streamers is given.

preprint2010arXiv

Multi-channel gas electron multiplier with metallic electrodes

The design of multi-channel gas electron multiplier (MGEM) with metallic electrodes is proposed, produced and tested. The electrodes of MGEM are produced from the brass plates with thickness of 1 mm, round openings of 1 mm in diameter and 1.5 mm steps between them. The gap between the electrodes is equal to 3 mm, while the total working area has a diameter of 20 mm. The neon gas fillings of the MWGEM chamber with micro admixtures of N_2 and H_2O have been tested. The total maximal coefficient of proportional multiplication of electrons in neon with admixture of (H_2O+N_2)<100 ppm of 30000 is obtained.

preprint2010arXiv

Multi-channel wire gas electron multipliers with gaps between the electrodes of 1 and 3mm

Multi-channel wire gas electron multipliers (MWGEM) with gaps between the electrodes of 1 and 3mm were investigated. The chamber of the MWGEM was filled with pure commercial neon gas at pressure of 0.4 or 1.0 bar and irradiated by alpha-particles (Pu-239) or beta-particles (Ni-63). The following maximal coefficients of electrons proportional multiplication have been obtained: 6 \times 10^3 (alpha, d=3mm, P=1bar, 20% streamers); 1.2 \times 10^3 (beta-, d=3mm, P=1bar, 50% streamers); 6 \times 10^3 (alpha, d=3mm, P=0.4bar, 20% streamers); 10^5 (beta-, d=3mm, P=0.4bar, 50% streamers). For the case, when the multiplication took place simultaneously in the MWGEM gap and in its anode gap, the following maximal coefficients of proportional multiplication of electrons have been obtained: 1.08 \times 10^5 (beta-, d=1mm, P=0.4bar, 50% streamers); 2 \times 10^6 (beta-, d=3mm, P=0.4bar, 20% streamers); 1.12 \times 10^5 (alpha, d=3mm, P=0.4bar, 50% streamers).