Researcher profile

You-Jin Yuan

You-Jin Yuan contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - Emerging
8works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2016arXiv

A data analysis method for isochronous mass spectrometry using two time-of-flight detectors at CSRe

The concept of isochronous mass spectrometry (IMS) applying two time-of-flight (TOF) detectors originated many years ago at GSI. However, the corresponding method for data analysis has never been discussed in detail. Recently, two TOF detectors have been installed at CSRe and the new working mode of the ring is under test. In this paper, a data analysis method for this mode is introduced and tested with a series of simulations. The results show that the new IMS method can significantly improve mass resolving power via the additional velocity information of stored ions. This improvement is especially important for nuclides with Lorentz factor $γ$-value far away from the transition point $γ_t$ of the storage ring CSRe.

preprint2016arXiv

Direct mass measurements of neutron-rich $^{86}$Kr projectile fragments and the persistence of neutron magic number $N$ = 32 in Sc isotopes

In this paper, we present direct mass measurements of neutron-rich $^{86}$Kr projectile fragments conducted at the HIRFL-CSR facility in Lanzhou by employing the Isochronous Mass Spectrometry (IMS) method. The new mass excesses of $^{52-54}$Sc nuclides are determined to be -40492(82), -38928(114), -34654(540) keV, which show a significant increase of binding energy compared to the reported ones in the Atomic Mass Evaluation 2012 (AME12). In particular, $^{53}$Sc and $^{54}$Sc are more bound by 0.8 MeV and 1.0 MeV, respectively. The behavior of the two neutron separation energy with neutron numbers indicates a strong sub-shell closure at neutron number $N$ = 32 in Sc isotopes.

preprint2016arXiv

Longitudinal RF capture simulation and BPM signal estimation

In this paper, the theoretical aspects behind longitudinal RF capture are reviewed and the capture process is simulated via a program based on this theory. Four kinds of cases with different initial distribution and capture curve are considered, i.e. uniform distribution with adiabatic capture, uniform distribution with non-adiabatic capture, Gaussian distribution with adiabatic capture and Gaussian distribution with non-adiabatic capture. The simulation results are compared each other and discussed, and Gaussian distribution with adiabatic capture is demonstrated having a higher capture efficiency and leading to a shorter bunch length. In addition, the BPM induced signal is simulated with high input impendence, i.e. $1MΩ$, and low input impendence, i.e. $50Ω$, respectively. Finally, the BPM signal of Heavy Ion Medical Machine (HIMM) is estimated and compared with measured one, and a good agreement is achieved.

preprint2015arXiv

Beam transport experiment with a new kicker control system on the HIRFL-CSR

The kicker control system was used for beam extraction and injection between two cooling storage rings (CSRs) at the Heavy Ion Research Facility in Lanzhou (HIRFL). To meet the requirements of special physics experiments, the kicker controller was upgraded. The new controller was designed based on ARM+DSP+FPGA technology and monolithic circuit architecture, which can achieve a precision time delay of 2.5 ns. In September 2014, the new kicker control system was installed in the kicker field, and the test experiment using the system was completed. In addition, a pre-trigger signal was provided by the controller, which was designed to synchronize the beam diagnostic system and physics experiments. Experimental results indicate that the phenomena of "missed kick" and "inefficient kick" were not observed, and the multichannel trigger signals' delay could be adjusted individually for kick power supplies in digitization; thus, the beam transport efficiency was improved compared with that of the original system. The fast extraction and injection experiment was successfully completed based on the new kicker control systems for HIRFL-CSR.

preprint2015arXiv

Calculation of the coupled betatron motion introduced by cooler's solenoids of CSRm

Several solenoids are usually installed in electron cooler device to guide the motion of the electron beam in the cooler. However, the solenoids also have influence to the ion beam in the cooler storage ring. The transverse motion of the ion beam in storage ring will become coupled, if the solenoids installed in the electron cooler are not compensated perfectly. In this paper, the coupled transverse motion due to the uncompensated cooler's solenoids of CSRm (The main storage ring in the IMP, Lan Zhou, China) is studied, and the coupled beam envelopes are calculated by a new method.

preprint2015arXiv

Simulation of proton radiography terminal at IMP

Proton radiography is used for advanced hydrotesting as a new type radiography technology due to its powerful penetration capability and high detection efficiency. A new proton radiography terminal will be developed to radiograph static samples at Institute of Modern Physics of Chinese Academy of Science (IMP-CAS). The proton beam with the maximum energy of 2.6 GeV will be produced by Heavy Ion Research Facility in Lanzhou-Cooling Storage Ring (HIRFL-CSR). The proton radiography terminal consists of the matching magnetic lens and the Zumbro lens system. In this paper, the design scheme and all optic parameters of this beam terminal for 2.6GeV proton energy are presented by simulating the beam optics using WINAGILE code. My-BOC code is used to test the particle tracking of proton radiography beam line. Geant4 code and G4beamline code are used for simulating the proton radiography system. The results show that the transmission efficiency of proton without target is 100%, and the effect of secondary particles can be neglected. In order to test this proton radiography system, the proton images for an aluminum plate sample with two rectangular orifices and a step brass plate sample are respectively simulated using Geant4 code. The results show that the best spatial resolution is about 36μm, and the differences of the thickness is not greater than 10%.

preprint2014arXiv

Research on the Design and Simulation of the CSRe Stochastic Cooling System

Stochastic cooling, as the different cooling mechanism from electron cooling, is designed and constructed on CSRe (experimental Cooling Storage Ring) in HIRFL (Heavy Ion Research Facility in Lanzhou) at present. The beam extracted from CSRm (main Cooling Storage Ring) is injected into the CSRe, and then the secondary beam with large momentum spread and large emittance is produced at the internal target area. This paper is designed to optimize the lattice of CSRe in order to satisfy the requirement of stochastic cooling system. Particle Tracking Method is used and both transverse and longitudinal simulation is made on the basis of the designed lattice. The results indicate that stochastic cooling is suitable for beam cooling with larger momentum spread or larger emittance, and cooling rate is preliminarily confirmed.

preprint2010arXiv

Study of magnetic alloy cores for HIRFL-CSRm compressor cavity

For selecting the properly magnetic alloy (MA) material to load the RF compression cavity, the measurement of the MA cores which is produced by Liyuan Company has been carried out at IMP. We measured 4 kinds of MA core materials, type V1, V2, A1 and A2. And we mainly focus on the permeability, quality factor (Q value) and shunt impedance of the MA core. The MA cores which have higher permeability, lower Q value and higher shunt impedance will be selected to load RF compression cavity. According to the results of measurement, the type V1, V2 and A2 material will be chosen as candidate to load RF cavity.