Source author record

Yoonseop Lee

Yoonseop Lee appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2014arXiv

Magnetic resonance-based reconstruction method of conductivity and permittivity distributions at the Larmor frequency

Magnetic resonance electrical property tomography is a recent medical imaging modality for visualizing the electrical tissue properties of the human body using radio-frequency magnetic fields. It uses the fact that in magnetic resonance imaging systems the eddy currents induced by the radio-frequency magnetic fields reflect the conductivity ($σ$) and permittivity ($ε$) distributions inside the tissues through Maxwell's equations. The corresponding inverse problem consists of reconstructing the admittivity distribution ($γ=σ+iωε$) at the Larmor frequency ($ω/2π=$128 MHz for a 3 tesla MRI machine) from the positive circularly polarized component of the magnetic field ${\bf H}=(H_x,H_y,H_z)$. Previous methods are usually based on an assumption of local homogeneity ($\nablaγ\approx 0$) which simplifies the governing equation. However, previous methods that include the assumption of homogeneity are prone to artifacts in the region where $γ$ varies. Hence, recent work has sought a reconstruction method that does not assume local-homogeneity. This paper presents a new magnetic resonance electrical property tomography reconstruction method which does not require any local homogeneity assumption on $γ$. We find that $γ$ is a solution of a semi-elliptic partial differential equation with its coefficients depending only on the measured data $H^+$, which enable us to compute a blurred version of $γ$. To improve the resolution of the reconstructed image, we developed a new optimization algorithm that minimizes the mismatch between the data and the model data as a highly nonlinear function of $γ$. Numerical simulations are presented to illustrate the potential of the proposed reconstruction method.