Researcher profile

Yong-Wei Dong

Yong-Wei Dong contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Discovery of oscillations above 200 keV in a black hole X-ray binary with Insight-HXMT

Low-frequency quasi-periodic oscillations (LFQPOs) are commonly found in black hole X-ray binaries, and their origin is still under debate. The properties of LFQPOs at high energies (above 30 keV) are closely related to the nature of the accretion flow in the innermost regions, and thus play a crucial role in critically testing various theoretical models. The Hard X-ray Modulation Telescope (Insight-HXMT) is capable of detecting emissions above 30 keV, and is therefore an ideal instrument to do so. Here we report the discovery of LFQPOs above 200 keV in the new black hole MAXI J1820+070 in the X-ray hard state, which allows us to understand the behaviours of LFQPOs at hundreds of kiloelectronvolts. The phase lag of the LFQPO is constant around zero below 30 keV, and becomes a soft lag (that is, the high-energy photons arrive first) above 30 keV. The soft lag gradually increases with energy and reaches ~0.9s in the 150-200 keV band. The detection at energies above 200 keV, the large soft lag and the energy-related behaviors of the LFQPO pose a great challenge for most currently existing models, but suggest that the LFQPO probably originates from the precession of a small-scale jet.

preprint2016arXiv

Perspective of monochromatic gamma-ray line detection with the High Energy cosmic-Radiation Detection (HERD) facility onboard China's Space Station

HERD is the High Energy cosmic-Radiation Detection instrument proposed to operate onboard China's space station in the 2020s. It is designed to detect energetic cosmic ray nuclei, leptons and photons with a high energy resolution ($\sim1\%$ for electrons and photons and $20\%$ for nuclei) and a large geometry factor ($>3\,{ m^2\,sr}$ for electrons and diffuse photons and $>2\,{ m^2\,sr}$ for nuclei). In this work we discuss the capability of HERD to detect monochromatic $γ$-ray lines, based on simulations of the detector performance. It is shown that HERD will be one of the most sensitive instruments for monochromatic $γ$-ray searches at energies between $\sim10$ to a few hundred GeV. Above hundreds of GeV, Cherenkov telescopes will be more sensitive due to their large effective area. As a specific example, we show that a good portion of the parameter space of a supersymmetric dark matter model can be probed with HERD.

preprint2016arXiv

Study of linearity of LYSO crystal for HERD calorimeter

The High Energy cosmic Radiation Detection (HERD) facility is a space mission designed for detecting cosmic ray (CR) electrons, $γ$-rays up to tens of TeV and CR nuclei from proton to iron up to several PeV. The main instrument of HERD is a 3-D imaging calorimeter (CALO) composed of nearly ten thousand cubic LYSO crystals. A large dynamic range of single HERD CALO Cell (HCC) is necessary to achieve HERD's PeV observation objectives, which means that the response of HCC should maintain a good linearity from minimum ionizing particle (MIP) calibration to PeV shower maximum. In order to study the linearity of HCC over such a large energy range, a beam test has been implemented at the E2 and E3 beam lines of BEPC. High intensity pulsed electron beam provided by E2 line are used for producing high energy density within HCC; $π^{+}$/proton provided by E3 line are used for HCC calibration. The results show that no saturation effect occurs and the linearity of HCC is better than 10% from 30 MeV (1 MIP) to 1.1$\times$10$^{3}$ TeV (energy density is 93 TeV/cm$^{3}$), which can meet the requirement mentioned above.

preprint2013arXiv

On-board GRB trigger algorithms of SVOM-GRM

GRM (Gamma-Ray Monitor) is the high energy detector on-board the future Chinese-French satellite SVOM (Space-based multi-band astronomical Variable Object Monitor) which is dedicated to Gamma-Ray Burst (GRB) studies. This paper presents the investigation of the on-board counting rate trigger algorithms of GRM. The trigger threshold and trigger efficiency based on the given GRB sample are calculated with the algorithms. The trigger characteristics of GRM and ECLAIRs are also analyzed. In addition, the impact of solar flares on GRM is estimated, and the method to distinguish solar flares from GRBs is investigated.