Researcher profile

Yong-Liang Wang

Yong-Liang Wang contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Transition edge sensor based detector: from X-ray to $γ$-ray

The Transition Edge Sensor is extremely sensitive to the change of temperature, combined with the high-Z metal of a certain thickness, it can realize the high energy resolution measurement of particles such as X-rays. X-rays with energies below 10 keV have very weak penetrating ability, so only a few microns thick of gold or bismuth can obtain quantum efficiency higher than 70\%. Therefore, the entire structure of the TES X-ray detector in this energy range can be realized in the microfabrication process. However, for X-rays or gamma rays from 10 keV to 200 keV, sub-millimeter absorber layers are required, which cannot be realized by microfabrication process. This paper first briefly introduces a set of TES X-ray detectors and their auxiliary systems built by ShanghaiTech University, then focus on the introduction of the TES $γ$-ray detector, with absorber based on an sub-millimeter lead-tin alloy sphere. The detector has a quantum efficiency above 70\% near 100 keV, and an energy resolution of about 161.5eV@59.5keV.

preprint2021arXiv

Multichannel adaptive signal detection: Basic theory and literature review

Multichannel adaptive signal detection jointly uses the test and training data to form an adaptive detector, and then make a decision on whether a target exists or not. Remarkably, the resulting adaptive detectors usually possess the constant false alarm rate (CFAR) properties, and hence no additional CFAR processing is needed. Filtering is not needed as a processing procedure either, since the function of filtering is embedded in the adaptive detector. Moreover, adaptive detection usually exhibits better detection performance than the filtering-then-CFAR detection technique. Multichannel adaptive signal detection has been more than 30 years since the first multichannel adaptive detector was proposed by Kelly in 1986. However, there are fewer overview articles on this topic. In this paper we give a tutorial overview of multichannel adaptive signal detection, with emphasis on Gaussian background. We present the main deign criteria for adaptive detectors, investigate the relationship between adaptive detection and filtering-then-CFAR detection, relationship between adaptive detectors and adaptive filters, summarize typical adaptive detectors, show numerical examples, give comprehensive literature review, and discuss some possible further research tracks.