Source author record

Yinong Liu

Yinong Liu appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2020arXiv

A PXI-based Multi-channel Data Acquisition System for Fast Transient Pulses

In this paper, we design a PXI-based, multi-channel data-acquisition system (DAS) mainly applicable to recording one-shot fast transient pulses in nuclear physics experiments. The system consists of one NI PXIe-1085 chassis, containing a controller card and at most 16 data-acquisition (DAQ) cards. Every single DAQ card has a sampling rate of 1GS/s and a 12bit vertical resolution with the PXI interface and SFP+ transceiver for data transmission. When the system is put into operation near the pulsed radiation source, the SFP+ optical fiber channel enables a timely data transmission to a remote server. All of these cards in the chassis can be synchronized using PXI timing and triggering resources. Additionally, a simple DAS software is developed to display the pulsed signals captured and communicate with the host PC for remote control and data upload. After careful calibration, preliminary tests show that every DAQ channel achieves an analog bandwidth higher than 200MHz and an ENOB of more than 9 bits at a 1GS/s sampling rate. Owing to such high speed and resolution, the system may facilitate improvements in extracting maximum information from transient signals. Furthermore, with great scalability and high-speed data transmission, the system can be used for other nuclear physics experiments.

preprint2020arXiv

Performance of Linear Classification Algorithms on alpha/gamma Discrimination for LaBr3:Ce Scintillation Detectors with Various Pulse Digitizer Properties

With the development of high-speed readout electronics, the digital pulse shape discrimination (PSD) methods have attracted the attention of more researchers, especially in the field of high energy physics and neutron detection. How to choose a PSD algorithm and corresponding data acquisition system (DAQ) naturally becomes a critical problem to settle down for the detection system designers. In this paper, the relationship between the classification performance of different PSD algorithms and digitizers' sampling properties (including sampling rate and the effective number of bits) has been researched based on $\mathrm{LaBr_3}$:Ce scintillation detectors. A self-developed integrated digitizer configured with five different ADCs and a WavePro 404HD oscilloscope were deployed to digitize the waveforms from $\mathrm{LaBr_3}$:Ce scintillators. Moreover, three PSD methods, charge comparison method (CCM), least square for classification method (LS) and Fisher's linear discriminant analysis (LDA), based on linear model were applied to discriminate the alpha signals from the intrinsic isotope $^{227}$Ac. With the LS method and a 125 MSPS 14-Bit ADC, the FoM value was 1.424$\pm$0.042, which is similar to the result from LDA but 31\% better than the result of CCM. The discrimination results showed that the performances of LS and LDA are less affected by the sampling rate with respect to the CCM method, which reflects in a better PSD capability. The results of this paper can help the developers of detector systems to make a trade-off among sampling properties, desirable discrimination results and the cost of systems.

preprint2019arXiv

Optimization of Energy Resolution and Pulse Shape Discrimination for a CLYC Detector with Integrated Digitizers

Sufficient current pulse information of nuclear radiation detectors can be retained by direct waveform digitization owing to the improvement of digitizer's performance. In many circumstances, reasonable cost and power consumption are on demand while the energy resolution and PSD performance should be ensured simultaneously for detectors. This paper will quantitatively analyse the influence of vertical resolution and sampling rate of digitizers on the energy resolution and PSD performance. The energy resolution and PSD performance can be generally optimized by improving the sampling rate and ENOB (effective number of bits) of digitizers. Several integrated digitizers, with sampling rates varying from 100 MSPS to 500 MSPS and vertical resolution ranging from 12-Bit to 16-Bit, were designed and integrated with a CLYC detector for verifications. Experimental results show good accordance with theoretical calculations. The conclusion can give guidance to designs of digitizes for similar applications in need of optimizing the energy resolution and PSD performance, and help to choose proper digitizers for different requirements.

preprint2019arXiv

Overview to the Hard X-ray Modulation Telescope (Insight-HXMT) Satellite

As China's first X-ray astronomical satellite, the Hard X-ray Modulation Telescope (HXMT), which was dubbed as Insight-HXMT after the launch on June 15, 2017, is a wide-band (1-250 keV) slat-collimator-based X-ray astronomy satellite with the capability of all-sky monitoring in 0.2-3 MeV. It was designed to perform pointing, scanning and gamma-ray burst (GRB) observations and, based on the Direct Demodulation Method (DDM), the image of the scanned sky region can be reconstructed. Here we give an overview of the mission and its progresses, including payload, core sciences, ground calibration/facility, ground segment, data archive, software, in-orbit performance, calibration, background model, observations and some preliminary results.

preprint2015arXiv

A Transmissive X-ray Polarimeter Design For Hard X-ray Focusing Telescopes

The X-ray Timing and Polarization (XTP) is a mission concept for a future space borne X-ray observatory and is currently selected for early phase study. We present a new design of X-ray polarimeter based on the time projection gas chamber. The polarimeter, placed above the focal plane, has an additional rear window that allows hard X-rays to penetrate (a transmission of nearly 80% at 6 keV) through it and reach the detector on the focal plane. Such a design is to compensate the low detection efficiency of gas detectors, at a low cost of sensitivity, and can maximize the science return of multilayer hard X-ray telescopes without the risk of moving focal plane instruments. The sensitivity in terms of minimum detectable polarization, based on current instrument configuration, is expected to be 3% for a 1mCrab source given an observing time of 10^5 s. We present preliminary test results, including photoelectron tracks and modulation curves, using a test chamber and polarized X-ray sources in the lab.