Source author record

Yingchao Du

Yingchao Du appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Advanced RF Structures for Wakefield Acceleration and High-Gradient Research

Structure wakefield acceleration (SWFA) is one of the most promising AAC schemes in several recent strategic reports, including DOE's 2016 AAC Roadmap, report on the Advanced and Novel Accelerators for High Energy Physics Roadmap (ANAR), and report on Accelerator and Beam Physics Research Goals and Opportunities. SWFA aims to raise the gradient beyond the limits of conventional radiofrequency (RF) accelerator technology, and thus the RF to beam energy efficiency, by reducing RF breakdowns from confining the microwave energy in a short (on the order of about 10 ns) and intense pulse excited by a drive beam. We envision that the following research topics, within the scope of AF7, are of great interest in the next decade: advanced wakefield structures, terahertz and sub-terahertz (THz) structures, and RF breakdown physics. Research on SWFA in the above directions would directly contribute to long-term large-scale applications, including AAC-based linear colliders and compact light sources. There is also potentially a strong synergy between SWFA and other AAC concepts, when structures are combined with plasmas into hybrid AAC schemes. Research on novel structures is at the core of advancing SWFA, and is critical to future AAC-based linear colliders; at the same, it has a strong synergy with other directions, such as cavity designs, high-power microwave systems and sources, and compact light sources.

preprint2022arXiv

Towards a compact all optical terahertz-driven electron source at Tsinghua University

We propose a physical design of a compact all optical terahertz (THz)-driven electron source. The 300 mm accelerator beamline, powered by Joule level laser system, is easily to be integrated to tabletop scale. A dual-feed THz-driven electron gun with an exponential impedance, a tapered dielectric loaded cylindrical waveguide, THz-driven bunch compressors and permanent magnet solenoids (PMS) have been designed and optimized. Dynamics simulations show that the electron source can deliver a 19 fC, 3 MeV electron beams with a normalized transverse emittance of 0.079 π.mm.mrad. A minimum relative energy spread of 0.04% or a minimum root-mean-square bunch length of 6.1 fs can be achieved by adjusting the beam shaping line. Sensitivity analysis shows that the THz-driven electron source can effectively work under a 1.5% energy jitter of the THz power system. Simulated diffraction pattern up to the fourth order of an aluminum sample based on the beamline can be clearly distinguished. A prototype THz gun has beam fabricated and is now under testing, more results will be reported in future works.

preprint2021arXiv

Eliminating uncertainty of thermal emittance measurement in solenoid scans due to rf and solenoid fields overlap

The solenoid scan is one of the most common methods for the in-situ measurement of the thermal emittance of a photocathode in an rf photoinjector. The fringe field of the solenoid overlaps with the gun rf field in quite a number of photoinjectors, which makes accurate knowledge of the transfer matrix challenging, thus increases the measurement uncertainty of the thermal emittance. This paper summarizes two methods that have been used to solve the overlap issue and explains their deficiencies. Furthermore, we provide a new method to eliminate the measurement error due to the overlap issue in solenoid scans. The new method is systematically demonstrated using theoretical derivations, beam dynamics simulations, and experimental data based on the photoinjector configurations from three different groups, proving that the measurement error with the new method is very small and can be ignored in most of the photoinjector configurations.

preprint2020arXiv

Rapid thermal emittance and quantum efficiency mapping of a cesium telluride cathode in an rf photoinjector using multiple laser beamlets

Thermal emittance and quantum efficiency (QE) are key figures of merit of photocathodes, and their uniformity is critical to high-performance photoinjectors. Several QE mapping technologies have been successfully developed; however, there is still a dearth of information on thermal emittance maps. This is because of the extremely time-consuming procedure to gather measurements by scanning a small beam across the cathode with fine steps. To simplify the mapping procedure, and to reduce the time required to take measurements, we propose a new method that requires only a single scan of the solenoid current to simultaneously obtain thermal emittance and QE distribution by using a pattern beam with multiple beamlets. In this paper, its feasibility has been confirmed by both beam dynamics simulation and theoretical analysis. The method has been successfully demonstrated in a proof-of-principle experiment using an L-band radiofrequency photoinjector with a cesium telluride cathode. In the experiment, seven beamlets were generated from a microlens array system and their corresponding thermal emittance and QE varied from 0.93 to 1.14 $μ$m/mm and from 4.6 to 8.7%, respectively. We also discuss the limitations and future improvements of the method in this paper.

preprint2015arXiv

Beam optical design for high energy electron radiography experiment study based on THU LINAC

A special beam line for high energy electron radiography is designed, including achromat and imaging systems. The requirement of the angle and position correction on the target from imaging system can be approximately realized by fine tuning the quadrupoles used in the achromat. The imaging system is designed by fully considering the limitation from the laboratory and beam diagnostics devices space. Two kinds of imaging system are designed and both show a good performance of imaging by beam trajectory simulation. The details of the beam optical requirement and optimization design are presented here. The beam line is designed and prepared to install in Tsinghua university linear electron accelerator laboratory for further precise electron radiography experiment study.

preprint2014arXiv

Bunch evolution study in optimization of MeV ultrafast electron diffraction

Megaelectronvolt ultrafast electron diffraction (UED) is a promising detection tool for ultrafast processes. The quality of diffraction image is determined by the transverse evolution of the probe bunch. In this paper, we study the contributing terms of the emittance and space charge effects to the bunch evolution in MeV UED scheme, employing a mean-field model with an ellipsoidal distribution as well as particle tracking simulation. Small transverse dimension of the drive laser is found critical to improve the reciprocal resolution, exploiting both smaller emittance and larger transverse bunch size before the solenoid. The degradation of reciprocal spatial resolution caused by the space charge effects should be carefully controlled.