Researcher profile

Yinan Hu

Yinan Hu contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2021arXiv

Battery characterization via eddy-current imaging with nitrogen-vacancy centers in diamond

Sensitive and accurate diagnostic technologies with magnetic sensors are of great importance for identifying and localizing defects of rechargeable solid batteries in a noninvasive detection. We demonstrate a microwave-free AC magnetometry method with negatively charged NV centers in diamond based on a cross-relaxation feature between NV centers and individual substitutional nitrogen (P1) centers occurring at 51.2 mT. We apply the technique to non-destructive solid-state battery imaging. By detecting the eddy-current-induced magnetic field of the battery, we distinguish a defect on the external electrode and identify structural anomalies within the battery body. The achieved spatial resolution is $360\,μ\rm m$. The maximum magnetic field and phase shift generated by the battery at the modulation frequency of 5 kHz are estimated as 0.04 mT and 0.03 rad respectively.

preprint2021arXiv

Photochemically induced dynamic nuclear polarization of heteronuclear singlet order

Photochemically induced dynamic nuclear polarization (photo-CIDNP) is a method to hyperpolarize nuclear spins using light. In most cases, CIDNP experiments are performed at a high magnetic field and the sample is irradiated by the light inside a nuclear magnetic resonance (NMR) spectrometer. Here we demonstrate photo-CIDNP hyperpolarization generated in the Earth magnetic field and under zero- to ultralow field (ZULF) conditions. Irradiating a sample for several seconds with inexpensive light-emitting diodes produces a strong hyperpolarization of 1H and 13C nuclear spins enhancing the NMR signals several hundred times. The hyperpolarized spin states at the Earth field and in ZULF are different. In the latter case, the state corresponds to the singlet order between scalar-coupled 1H-13C nuclear spins. This state has a longer lifetime than the state hyperpolarized at Earth field. The method is simple and cost-efficient and should be applicable to many molecular systems known to exhibit photo-CIDNP, including amino acids and nucleotides.

preprint2020arXiv

Biomagnetic signals recorded during transcranial magnetic stimulation (TMS)-evoked peripheral muscular activity

Objective: We present magnetomyograms (MMG) of TMS-evoked movement in a human hand, together with a simultaneous surface electromyograph (EMG) and electroencephalograph (EEG) data. Approach: We combined TMS with non-contact magnetic detection of TMS-evoked muscle activity in peripheral limbs to explore a new diagnostic modality that enhances the utility of TMS as a clinical tool by leveraging technological advances in magnetometry. We recorded measurements in a regular hospital room using an array of optically pumped magnetometers (OPM) inside a portable shield that encompasses only the forearm and hand of the subject. Main Results: The biomagnetic signals recorded in the MMG provide detailed spatial and temporal information that is complementary to that of the electric signal channels. Moreover, we identify features in the magnetic recording beyond those of the EMG. Significance: These results validate the viability of MMG recording with a compact OPM based setup in small-sized magnetic shielding, and provide proof-of-principle for a non-contact data channel for detection and analysis of TMS-evoked muscle activity from peripheral limbs.

preprint2019arXiv

Zero- to Ultralow-Field Nuclear Magnetic Resonance $J$-Spectroscopy with Commercial Atomic Magnetometers

Zero- to ultralow-field nuclear magnetic resonance (ZULF NMR) is an alternative spectroscopic method to high-field NMR, in which samples are studied in the absence of a large magnetic field. Unfortunately, there is a large barrier to entry for many groups, because operating the optical magnetometers needed for signal detection requires some expertise in atomic physics and optics. Commercially available magnetometers offer a solution to this problem. Here we describe a simple ZULF NMR configuration employing commercial magnetometers, and demonstrate sufficient functionality to measure samples with nuclear spins prepolarized in a permanent magnet or initialized using parahydrogen. This opens the possibility for other groups to use ZULF NMR, which provides a means to study complex materials without magnetic susceptibility-induced line broadening, and to observe samples through conductive materials.