Source author record

Yigang Yang

Yigang Yang appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2016arXiv

A Capture-gated Fast Neutron Detection Method

To address the problem of the shortage of neutron detectors used in radiation portal monitors (RPMs), caused by the 3He supply crisis, research on a cadmium-based capture-gated fast neutron detector is presented in this paper. The detector is composed of many 1 cm * 1 cm * 20 cm plastic scintillator cuboids covered by 0.1 mm thick film of cadmium. The detector uses cadmium to absorb thermal neutrons and produce capture gamma-rays to indicate the detection of neutrons, and uses plastic scintillator to moderate neutrons and register gamma-rays. This design removes the volume competing relationship in traditional 3He counter-based fast neutron detectors, which hinders enhancement of the neutron detection efficiency. Detection efficiency of 21.66 +- 1.22% has been achieved with a 40.4 cm * 40.4 cm * 20 cm overall detector volume. This detector can measure both neutrons and gamma-rays simultaneously. A small detector (20.2 cm * 20.2 cm * 20 cm) demonstrated a 3.3 % false alarm rate for a 252Cf source with a neutron yield of 1841 n/s from 50 cm away within 15 seconds measurement time. It also demonstrated a very low (< 0.06%) false alarm rate for a 3.21 * 105 Bq 137Cs source. This detector offers a potential single-detector replacement for both neutron and the gamma-ray detectors in RPM systems.

preprint2013arXiv

High efficiency event-counting thermal neutron imaging using Gd doped micro channel plate

An event-counting thermal neutron imaging detector based on 3 mol % natGd2O3 doped micro channel plate (MCP) has been developed and tested. Thermal neutron imaging experiment was carried out with a low flux neutron beam. Detection efficiency of 33 % was achieved with only one doped MCP. The spatial resolution of 72 μm RMS is currently limited by the readout anode. A detector with larger area and improved readout method is now being developed.