Researcher profile

Yanlin Huang

Yanlin Huang contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
12works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

12 published item(s)

preprint2023arXiv

A First Search for Solar $^8$B Neutrino in the PandaX-4T Experiment using Neutrino-Nucleus Coherent Scattering

A search for interactions from solar $^8$B neutrinos elastically scattering off xenon nuclei using PandaX-4T commissioning data is reported. The energy threshold of this search is further lowered compared with the previous search for dark matter, with various techniques utilized to suppress the background that emerges from data with the lowered threshold. A blind analysis is performed on the data with an effective exposure of 0.48 tonne$\cdot$year, and no significant excess of events is observed. Among results obtained using the neutrino-nucleus coherent scattering, our results give the best constraint on the solar $^8$B neutrino flux. We further provide a more stringent limit on the cross section between dark matter and nucleon in the mass range from 3 to 9 GeV/c$^2$.

preprint2022arXiv

A Search for the Cosmic Ray Boosted Sub-GeV Dark Matter at the PandaX-II Experiment

We report a novel search for the cosmic ray boosted dark matter using the 100~tonne$\cdot$day full data set of the PandaX-II detector located at the China Jinping Underground Laboratory. With the extra energy gained from the cosmic rays, sub-GeV dark matter particles can produce visible recoil signals in the detector. The diurnal modulations in rate and energy spectrum are utilized to further enhance the signal sensitivity. Our result excludes the dark matter-nucleon elastic scattering cross section between 10$^{-31}$cm$^{2}$ and 10$^{-28}$cm$^{2}$ for a dark matter masses from 0.1 MeV/$c^2$ to 0.1 GeV/$c^2$, with a large parameter space previously unexplored by experimental collaborations.

preprint2022arXiv

A search for two-component Majorana dark matter in a simplified model using the full exposure data of PandaX-II experiment

In the two-component Majorana dark matter model, one dark matter particle can scatter off the target nuclei, and turn into a slightly heavier component. In the framework of a simplified model with a vector boson mediator, both the tree-level and loop-level processes contribute to the signal in direct detection experiment. In this paper, we report the search results for such dark matter from PandaX-II experiment, using total data of the full 100.7 tonne$\cdot$day exposure. No significant excess is observed, so strong constraints on the combined parameter space of mediator mass and dark matter mass are derived. With the complementary search results from collider experiments, a large range of parameter space can be excluded.

preprint2022arXiv

Low Radioactive Material Screening and Background Control for the PandaX-4T Experiment

PandaX-4T is a ton-scale dark matter direct detection experiment using a dual-phase TPC technique at the China Jinping Underground Laboratory. Various ultra-low background technologies have been developed and applied to material screening for PandaX-4T, including HPGe gamma spectroscopy, ICP-MS, NAA, radon emanation measurement system, krypton assay station, and alpha detection system. Low background materials were selected to assemble the detector. Surface treatment procedures were investigated to further suppress radioactive background. Combining measured results and Monte Carlo simulation, the total material background rates of PandaX-4T in the energy region of 1-25 keV$\rm{}_{ee}$ are estimated to be (9.9 $\pm$ 1.9) $\times \ 10^{-3}$ mDRU for electron recoil and (2.8 $\pm$ 0.6) $\times \ 10^{-4}$ mDRU for nuclear recoil. In addition, $^{nat}$Kr in the detector is estimated to be <8 ppt.

preprint2022arXiv

Neutron-induced nuclear recoil background in the PandaX-4T experiment

Neutron-induced nuclear recoil background is critical to the dark matter searches in the PandaX-4T liquid xenon experiment. This paper studies the feature of neutron background in liquid xenon and evaluates their contribution in the single scattering nuclear recoil events through three methods. The first method is fully Monte Carlo simulation based. The last two are data-driven methods that also use the multiple scattering signals and high energy signals in the data, respectively. In the PandaX-4T commissioning data with an exposure of 0.63 tonne-year, all these methods give a consistent result that there are $1.15\pm0.57$ neutron-induced background in dark matter signal region within an approximated nuclear recoil energy window between 5 and 100 keV.

preprint2022arXiv

Readout electronics and data acquisition system of PandaX-4T experiment

PandaX-4T is a dark matter direct detection experiment located in China jinping underground laboratory. The central apparatus is a dual-phase xenon detector containing 4 ton liquid xenon in the sensitive volume, with about 500 photomultipliers instrumented in the top and the bottom of the detector. In this paper we present a completely new system of readout electronics and data acquisition in the PandaX-4T experiment. Compared to the one used in the previous PandaX dark matter experiments, the new system features triggerless readout and higher bandwidth. With triggerless readout, dark matter searches are not affected by the efficiency loss of external triggers. The system records single photelectron signals of the dominant PMTs with an average efficiency of 96\%, and achieves the bandwidth of more than 450 MB/s. The system has been used to successfully acquire data during the commissioning runs of PandaX-4T.

preprint2022arXiv

Study of background from accidental coincidence signals in the PandaX-II experiment

The PandaX-II experiment employed a 580kg liquid xenon detector to search for the interactions between dark matter particles and the target xenon atoms. The accidental coincidences of isolated signals result in a dangerous background which mimic the signature of the dark matter. We performed a detailed study on the accidental coincidence background in PandaX-II, including the possible origin of the isolated signals, the background level and corresponding background suppression method. With a boosted-decision-tree algorithm, the accidental coincidence background is reduced by 70% in the dark matter signal region, thus the sensitivity of dark matter search at PandaX-II is improved.

preprint2021arXiv

Dark Matter Search Results from the PandaX-4T Commissioning Run

We report the first dark matter search results using the commissioning data from PandaX-4T. Using a time projection chamber with 3.7-tonne of liquid xenon target and an exposure of 0.63 tonne$\cdot$year, 1058 candidate events are identified within an approximate nuclear recoil energy window between 5 and 100 keV. No significant excess over background is observed. Our data set a stringent limit to the dark matter-nucleon spin-independent interactions, with a lowest excluded cross section (90% C.L.) of $3.8\times10^{-47} $cm$^2$ at a dark matter mass of 30 GeV/$c^2$.

preprint2021arXiv

Internal Calibration of the PandaX-II Detector with Radon Gaseous Sources

We have developed a low-energy electron recoil (ER) calibration method with $^{220}$Rn for the PandaX-II detector. $^{220}$Rn, emanated from natural thorium compounds, was fed into the detector through the xenon purification system. From 2017 to 2019, we performed three dedicated calibration campaigns with different radon sources. We studied the detector response to $α$, $β$, and $γ$ particles with focus on low energy ER events. During the runs in 2017 and 2018, the amount of radioactivity of $^{222}$Rn were on the order of 1\% of that of $^{220}$Rn and thorium particulate contamination was negligible, especially in 2018. We also measured the background contribution from $^{214}$Pb for the first time in PandaX-II with the help from a $^{222}$Rn injection. Calibration strategy with $^{220}$Rn and $^{222}$Rn will be implemented in the upcoming PandaX-4T experiment and can be useful for other xenon-based detectors as well.

preprint2021arXiv

Light yield and field dependence measurement in PandaX-II dual-phase xenon detector

The dual-phase xenon time projection chamber (TPC) is one of the most sensitive detector technology for dark matter direct search, where the energy deposition of incoming particle can be converted into photons and electrons through xenon excitation and ionization. The detector response to signal energy deposition varies significantly with the electric field in liquid xenon. We study the detector&#39;s light yield and its dependence on the electric field in the PandaX-II dual-phase detector containing 580~kg liquid xenon in the sensitive volume. From our measurements, the light yield at electric fields from 0~V/cm to 317~V/cm is obtained for energy depositions up to 236~keV.

preprint2021arXiv

Results of Dark Matter Search using the Full PandaX-II Exposure

We report the dark matter search results obtained using the full 132 ton$\cdot$day exposure of the PandaX-II experiment, including all data from March 2016 to August 2018. No significant excess of events is identified above the expected background. Upper limits are set on the spin-independent dark matter-nucleon interactions. The lowest 90% confidence level exclusion on the spin-independent cross section is $2.2\times 10^{-46}$ cm$^2$ at a WIMP mass of 30 GeV/$c^2$.

preprint2019arXiv

Searching for Neutrino-less Double Beta Decay of $^{136}$Xe with PandaX-II Liquid Xenon Detector

We report the Neutrino-less Double Beta Decay (NLDBD) search results from PandaX-II dual-phase liquid xenon time projection chamber. The total live time used in this analysis is 403.1 days from June 2016 to August 2018. With NLDBD-optimized event selection criteria, we obtain a fiducial mass of 219 kg of natural xenon. The accumulated xenon exposure is 242 kg$\cdot$yr, or equivalently 22.2 kg$\cdot$yr of $^{136}$Xe exposure. At the region around $^{136}$Xe decay Q-value of 2458 keV, the energy resolution of PandaX-II is 4.2%. We find no evidence of NLDBD in PandaX-II and establish a lower limit for decay half-life of 2.4 $ \times 10^{23} $ yr at the 90% confidence level, which corresponds to an effective Majorana neutrino mass $m_{ββ} < (1.3 - 3.5)$ eV. This is the first NLDBD result reported from a dual-phase xenon experiment.