Source author record

Yang Weng

Yang Weng appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
8topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Explainable Graph Theory-Based Identification of Meter-Transformer Mapping

Distributed energy resources are better for the environment but may cause transformer overload in distribution grids, calling for recovering meter-transformer mapping to provide situational awareness, i.e., the transformer loading. The challenge lies in recovering meter-transformer (M.T.) mapping for two common scenarios, e.g., large distances between a meter and its parent transformer or high similarity of a meter's consumption pattern to a non-parent transformer's meters. Past methods either assume a variety of data as in the transmission grid or ignore the two common scenarios mentioned above. Therefore, we propose to utilize the above observation via spectral embedding by using the property that inter-transformer meter consumptions are not the same and that the noise in data is limited so that all the k smallest eigenvalues of the voltage-based Laplacian matrix are smaller than the next smallest eigenvalue of the ideal Laplacian matrix. We also provide a guarantee based on this understanding. Furthermore, we partially relax the assumption by utilizing location information to aid voltage information for areas geographically far away but with similar voltages. Numerical simulations on the IEEE test systems and real feeders from our partner utility show that the proposed method correctly identifies M.T. mapping.

preprint2022arXiv

Local Measurement Based Robust Voltage Stability Index & Identification of Voltage Collapse Onset

This paper addresses the problem of real-time monitoring of long-term voltage instability (LTVI) by using local field measurements. Existing local measurement-based methods use Thevenin equivalent parameter estimation that is sensitive to the noise in measurements. For solving this issue, we avoid the Thevenin approach by projecting the power flow equations as circles to develop local static-voltage stability indicator (LS-VSI) that is robust to measurement noises. The proposed method is an attractive option for practical implementation because of its decentralized nature, robustness to noise, and realistic modeling. Next, we utilize LS-VSI to propose a new local dynamic - VSI (LD-VSI) to identify the LTVI triggered by large disturbances and load tap changer dynamics. LD-VSI can identify not only the onset of instability with an alarm but also the voltage collapse point (VCP). Extensive numerical validation comparing LS-VSI with existing methods is presented on IEEE 30-bus and larger test systems like 2000-bus Texas synthetic grid to validate the robustness, accuracy, and situational awareness feature. We also verify the LD-VSI behavior on the Nordic power grid using PSSE dynamic simulation. When compared to existing methods, we observe that LD-VSI is not only more robust to measurement noise but also can identify VCP.

preprint2020arXiv

Wide Area Measurement System-based Low Frequency Oscillation Damping Control through Reinforcement Learning

Ensuring the stability of power systems is gaining more attraction today than ever before, due to the rapid growth of uncertainties in load and renewable energy penetration. Lately, wide area measurement system-based centralized controlling techniques started providing a more flexible and robust control to keep the system stable. But, such a modernization of control philosophy faces pressing challenges due to the irregularities in delays of long-distance communication channels and response of equipment to control actions. Therefore, we propose an innovative approach that can revolutionize the control strategy for damping down low frequency oscillations in transmission systems. Proposed method is enriched with a potential of overcoming the challenges of communication delays and other non-linearities in wide area damping control by leveraging the capability of the reinforcement learning technique. Such a technique has a unique characteristic to learn on diverse scenarios and operating conditions by exploring the environment and devising an optimal control action policy by implementing policy gradient method. Our detailed analysis and systematically designed numerical validation prove the feasibility, scalability and interpretability of the carefully modelled low-frequency oscillation damping controller so that stability is ensured even with the uncertainties of load and generation are on the rise.

preprint2012arXiv

An Information-Theoretic Approach to PMU Placement in Electric Power Systems

This paper presents an information-theoretic approach to address the phasor measurement unit (PMU) placement problem in electric power systems. Different from the conventional 'topological observability' based approaches, this paper advocates a much more refined, information-theoretic criterion, namely the mutual information (MI) between the PMU measurements and the power system states. The proposed MI criterion can not only include the full system observability as a special case, but also can rigorously model the remaining uncertainties in the power system states with PMU measurements, so as to generate highly informative PMU configurations. Further, the MI criterion can facilitate robust PMU placement by explicitly modeling probabilistic PMU outages. We propose a greedy PMU placement algorithm, and show that it achieves an approximation ratio of (1-1/e) for any PMU placement budget. We further show that the performance is the best that one can achieve in practice, in the sense that it is NP-hard to achieve any approximation ratio beyond (1-1/e). Such performance guarantee makes the greedy algorithm very attractive in the practical scenario of multi-stage installations for utilities with limited budgets. Finally, simulation results demonstrate near-optimal performance of the proposed PMU placement algorithm.