Researcher profile

Di Shi

Di Shi contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
13works
0followers
7topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

13 published item(s)

preprint2022arXiv

Coordinated Frequency Control through Safe Reinforcement Learning

With widespread deployment of renewables, the electric power grids are experiencing increasing dynamics and uncertainties, with its secure operation being threatened. Existing frequency control schemes based on day-ahead offline analysis and minute-level online sensitivity calculations are difficult to adapt to rapidly changing system states. In particular, they are unable to facilitate coordinated control of system frequency and power flows. A refined approach and tools are urgently needed to assist system operators to make timely decisions. This paper proposes a novel model-free coordinated frequency control framework based on safe reinforcement learning, with multiple control objectives considered. The load frequency control problem is modeled as a constrained Markov decision process, which can be solved by an AI agent continuously interacting with the grid to achieve sub-second decision making. Extensive numerical experiments conducted at East China Power Grid demonstrate the effectiveness and promise of the proposed method.

preprint2022arXiv

The Padé matrix pencil method with spurious pole information assimilation

We present a novel method for calculating Padé approximants that is capable of eliminating spurious poles placed at the point of development and of identifying and eliminating spurious poles created by precision limitations and/or noisy coefficients. Information contained in in the eliminated poles is assimilated producing a reduced order Padé approximant (PA). While the [m+k/m] conformation produced by the algorithm is flexible, the m value of the rational approximant produced by the algorithm reported here is determined by the number of spurious poles eliminated. Spurious poles due to coefficient noise/precision limitations are identified using an evidence-based filter parameter applied to the singular values of a matrix comprised of the series coefficients. The rational function poles are found directly by solving a generalized eigenvalue problem defined by a matrix pencil. Spurious poles place at the point of development, responsible in some algorithms for degeneracy, are identified by their magnitudes. Residues are found by solving an overdetermined linear matrix equation. The method is compared with the so-called Robust Padé Approximation (RPA) method and shown to be competitive on the problems studied. By eliminating spurious poles, particularly in functions with branch points, such as those encountered solving the power-flow problem, solution of these complex-valued problems is made more reliable.

preprint2020arXiv

Deriving AC OPF Solutions via Proximal Policy Optimization for Secure and Economic Grid Operation

Optimal power flow (OPF) is a very fundamental but vital optimization problem in the power system, which aims at solving a specific objective function (ex.: generator costs) while maintaining the system in the stable and safe operations. In this paper, we adopted the start-of-the-art artificial intelligence (AI) techniques to train an agent aiming at solving the AC OPF problem, where the nonlinear power balance equations are considered. The modified IEEE-14 bus system were utilized to validate the proposed approach. The testing results showed a great potential of adopting AI techniques in the power system operations.

preprint2020arXiv

Distributed Frequency Emergency Control with Coordinated Edge Intelligence

Developing effective strategies to rapidly support grid frequency while minimizing loss in case of severe contingencies is an important requirement in power systems. While distributed responsive load demands are commonly adopted for frequency regulation, it is difficult to achieve both rapid response and global accuracy in a practical and cost-effective manner. In this paper, the cyber-physical design of an Internet-of-Things (IoT) enabled system, called Grid Sense, is presented. Grid Sense utilizes a large number of distributed appliances for frequency emergency support. It features a local power loss $ΔP$ estimation approach for frequency emergency control based on coordinated edge intelligence. The specifically designed smart outlets of Grid Sense detect the frequency disturbance event locally using the parameters sent from the control center to estimate active power loss in the system and to make rapid and accurate switching decisions soon after a severe contingency. Based on a modified IEEE 24-bus system, numerical simulations and hardware experiments are conducted to demonstrate the frequency support performance of Grid Sense in the aspects of accuracy and speed. It is shown that Grid Sense equipped with its local $ΔP$-estimation frequency control approach can accurately and rapidly prevent the drop of frequency after a major power loss.

preprint2020arXiv

Evaluating Load Models and Their Impacts on Power Transfer Limits

Power transfer limits or transfer capability (TC) directly relate to the system operation and control as well as electricity markets. As a consequence, their assessment has to comply with static constraints, such as line thermal limits, and dynamic constraints, such as transient stability limits, voltage stability limits and small-signal stability limits. Since the load dynamics have substantial impacts on power system transient stability, load models are one critical factor that affects the power transfer limits. Currently, multiple load models have been proposed and adopted in the industry and academia, including the ZIP model, ZIP plus induction motor composite model (ZIP + IM) and WECC composite load model (WECC CLM). Each of them has its unique advantages, but their impacts on the power transfer limits are not yet adequately addressed. One existing challenge is fitting the high-order nonlinear models such as WECC CLM. In this study, we innovatively adopt double deep Q-learning Network (DDQN) agent as a general load modeling tool in the dynamic assessment procedure and fit the same transient field measurements into different load models. A comprehensive evaluation is then conducted to quantify the load models' impacts on the power transfer limits. The simulation environment is the IEEE-39 bus system constructed in Transient Security Assessment Tool (TSAT).

preprint2020arXiv

Extended Prony Analysis on Power System Oscillation Under a Near-Resonance Condition

Power system oscillations under a large disturbance often exhibit distorted waveforms as captured by increasingly deployed phasor measurement units. One cause is the occurrence of a near-resonance condition among several dominant modes that are influenced by nonlinear transient dynamics of generators. This paper proposes an Extended Prony Analysis method for measurement-based modal analysis. Based on the normal form theory, it compares analyses on transient and post-transient waveforms to distinguish a resonance mode caused by a near-resonance condition from natural modes so that the method can give more accurate modal properties than a traditional Prony Analysis method, especially for large disturbances. The new method is first demonstrated in detail on Kundur's two-area system and then tested on the IEEE 39-bus system to show its performance under a near-resonance condition.

preprint2020arXiv

Global Sensitivity Analysis in Load Modeling via Low-rank Tensor

Growing model complexities in load modeling have created high dimensionality in parameter estimations, and thereby substantially increasing associated computational costs. In this paper, a tensor-based method is proposed for identifying composite load modeling (CLM) parameters and for conducting a global sensitivity analysis. Tensor format and Fokker-Planck equations are used to estimate the power output response of CLM in the context of simultaneously varying parameters under their full parameter distribution ranges. The proposed tensor structured is shown as effective for tackling high-dimensional parameter estimation and for improving computational performances in load modeling through global sensitivity analysis.

preprint2020arXiv

Implications of Stahl's Theorems to Holomorphic Embedding Pt. 1: Theoretical Convergence

What has become known as Stahl's Theorem in power engineering circles has been used to justify a convergence guarantee of the Holormorphic Embedding Method (HEM) as it applies to the power flow (PF) problem. In this two-part paper, we examine in more detail the implications of Stahl's theorems to both theoretcial and numerical convergence for a wider range of problems to which these theorems are now being applied. In Pt. 1, we introduce the theorem using the necessary mathematical parlance and then translate the language to show its implications to convergence of nonlinear problems in general and the PF problem specifically. We show that among other possibilities the existence of the Chebotarev points, which are embedding specific, are a possible theoretical impediment to convergence. Numerical impediments to convergences are discussed in the companion paper.

preprint2020arXiv

Implications of Stahl's Theorems to Holomorphic Embedding Pt. 2: Numerical Convergence

What has become known as Stahl's Theorem in power-engineering circles has been used to justify a convergence guarantee of the Holomorphic Embedding Method (HEM) as it applies to the power-flow problem. In this, the second part of a two-part paper, we examine implications to numerical convergence of HEM and the numerical properties of a Padé approximant algorithm. We show that even if the convergence domain is identical to the function's domain, numerical convergence of the sequence of Padé approximants computed with finite precision is not guaranteed. We also show that the study of convergence properties of the Padé approximant is the study of the location of branch-points of the function, which dictate branch-cut topology and capacity and, therefore, convergence rate. We show how poorly chosen embeddings can prevent numerical convergence.

preprint2020arXiv

Online Low Frequency Oscillation Detection and Analysis System with an Ensemble Filter

The widespread deployment of phasor measurement unit (PMU) overpower systems makes it possible to monitor and analyze grid dynamics in real-time. Low-frequency oscillation is harmful to power system equipment and operation, and in the worst-case scenario may lead to cascading failures. Therefore, it is critical to detect and identify them as soon as they appear. This paper presents an online low-frequency oscillation detection and analysis (LFODA) system, which has the merit of significantly reducing the chance of false alarm via a voting schema and a time-serial filter. A novel algorithm based on density-based spatial clustering of applications with noise (DBSCAN) is proposed to classify oscillation modes as well as to group their corresponding buses/monitoring sites. Performance of the LFODA system is evaluated through experiments using both simulated and real-world PMU data.

preprint2020arXiv

Time Series Classification for Locating Forced Oscillation Sources

Forced oscillations are caused by sustained cyclic disturbances. This paper presents a machine learning (ML) based time-series classification method that uses the synchrophasor measurements to locate the sources of forced oscillations for fast disturbance removal. Sequential feature selection is used to identify the most informative measurements of each power plant so that multivariate time series (MTS) can be constructed. By training the Mahalanobis matrix, we measure and compare the distance between the MTSs. Templates for representing each class is constructed to reduce the size of training datasets and improve the online matching efficiency. Dynamic time warping (DTW) algorithm is used to align the out-of-sync MTSs to account for oscillation detection errors. The algorithm is validated on two test systems: the IEEE 39-bus system and the WECC 179-bus system. When a forced oscillation occurs, MTSs will be constructed by designated PMU measurements. Then, the MTSs will be classified by the trained classifiers, the class membership of which corresponds to the location of each oscillation source. Simulation results show that the proposed method can be used online to identify the forced oscillation sources with high accuracy. The robustness of the proposed algorithm in the presence of oscillation detection errors is also quantified.

preprint2020arXiv

Two-stage WECC Composite Load Modeling: A Double Deep Q-Learning Networks Approach

With the increasing complexity of modern power systems, conventional dynamic load modeling with ZIP and induction motors (ZIP + IM) is no longer adequate to address the current load characteristic transitions. In recent years, the WECC composite load model (WECC CLM) has shown to effectively capture the dynamic load responses over traditional load models in various stability studies and contingency analyses. However, a detailed WECC CLM model typically has a high degree of complexity, with over one hundred parameters, and no systematic approach to identifying and calibrating these parameters. Enabled by the wide deployment of PMUs and advanced deep learning algorithms, proposed here is a double deep Q-learning network (DDQN)-based, two-stage load modeling framework for the WECC CLM. This two-stage method decomposes the complicated WECC CLM for more efficient identification and does not require explicit model details. In the first stage, the DDQN agent determines an accurate load composition. In the second stage, the parameters of the WECC CLM are selected from a group of Monte-Carlo simulations. The set of selected load parameters is expected to best approximate the true transient responses. The proposed framework is verified using an IEEE 39-bus test system on commercial simulation platforms.

preprint2020arXiv

Wide Area Measurement System-based Low Frequency Oscillation Damping Control through Reinforcement Learning

Ensuring the stability of power systems is gaining more attraction today than ever before, due to the rapid growth of uncertainties in load and renewable energy penetration. Lately, wide area measurement system-based centralized controlling techniques started providing a more flexible and robust control to keep the system stable. But, such a modernization of control philosophy faces pressing challenges due to the irregularities in delays of long-distance communication channels and response of equipment to control actions. Therefore, we propose an innovative approach that can revolutionize the control strategy for damping down low frequency oscillations in transmission systems. Proposed method is enriched with a potential of overcoming the challenges of communication delays and other non-linearities in wide area damping control by leveraging the capability of the reinforcement learning technique. Such a technique has a unique characteristic to learn on diverse scenarios and operating conditions by exploring the environment and devising an optimal control action policy by implementing policy gradient method. Our detailed analysis and systematically designed numerical validation prove the feasibility, scalability and interpretability of the carefully modelled low-frequency oscillation damping controller so that stability is ensured even with the uncertainties of load and generation are on the rise.