Source author record

Y. -R. Yen

Y. -R. Yen appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

31works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

31 published item(s)

preprint2022arXiv

Measurement of the Coherent Elastic Neutrino-Nucleus Scattering Cross Section on CsI by COHERENT

We measured the cross section of coherent elastic neutrino-nucleus scattering (\cevns{}) using a CsI[Na] scintillating crystal in a high flux of neutrinos produced at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. New data collected before detector decommissioning has more than doubled the dataset since the first observation of \cevns{}, achieved with this detector. Systematic uncertainties have also been reduced with an updated quenching model, allowing for improved precision. With these analysis improvements, the COHERENT collaboration determined the cross section to be $(165^{+30}_{-25})\times10^{-40}$~cm$^2$, consistent with the standard model, giving the most precise measurement of \cevns{} yet. The timing structure of the neutrino beam has been exploited to compare the \cevns{} cross section from scattering of different neutrino flavors. This result places leading constraints on neutrino non-standard interactions while testing lepton flavor universality and measures the weak mixing angle as $\sin^2θ_{W}=0.220^{+0.028}_{-0.026}$ at $Q^2\approx(50\text{ MeV})^2$

preprint2022arXiv

Monitoring the SNS basement neutron background with the MARS detector

We present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the SNS basement corridor. This is the basement location of closest proximity to the SNS target and thus, of highest neutrino flux, but it is also well shielded from the BRN flux by infill concrete and gravel. These data show the detector registered roughly one BRN per day. Using MARS' measured detection efficiency, the incoming BRN flux is estimated to be $1.20~\pm~0.56~\text{neutrons}/\text{m}^2/\text{MWh}$ for neutron energies above $\sim3.5$ MeV and up to a few tens of MeV. We compare our results with previous BRN measurements in the SNS basement corridor reported by other neutron detectors.

preprint2022arXiv

Simulating the neutrino flux from the Spallation Neutron Source for the COHERENT experiment

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is a pulsed source of neutrons and, as a byproduct of this operation, an intense source of pulsed neutrinos via stopped-pion decay. The COHERENT collaboration uses this source to investigate coherent elastic neutrino-nucleus scattering and other physics with a suite of detectors. This work includes a description of our Geant4 simulation of neutrino production at the SNS and the flux calculation which informs the COHERENT studies. We estimate the uncertainty of this calculation at about 10% based on validation against available low-energy pion production data.

preprint2022arXiv

The COHERENT Experimental Program

The COHERENT experiment located in Neutrino Alley at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL), has made the world's first two measurements of coherent elastic neutrino-nucleus scattering (CEvNS), on CsI and argon, using neutrinos produced at the SNS. The COHERENT collaboration continues to pursue CEvNS measurements on various targets as well as additional studies of inelastic neutrino-nucleus interactions, searches for accelerator-produced dark matter (DM) and physics beyond the Standard Model, using the uniquely high-quality and high-intensity neutrino source available at the SNS. This white paper describes primarily COHERENT's ongoing and near-future program at the SNS First Target Station (FTS). Opportunities enabled by the SNS Second Target Station (STS) for the study of neutrino physics and development of novel detector technologies are elaborated in a separate white paper.

preprint2021arXiv

First Measurement of Coherent Elastic Neutrino-Nucleus Scattering on Argon

We report the first measurement of coherent elastic neutrino-nucleus scattering (\cevns) on argon using a liquid argon detector at the Oak Ridge National Laboratory Spallation Neutron Source. Two independent analyses prefer \cevns over the background-only null hypothesis with greater than $3σ$ significance. The measured cross section, averaged over the incident neutrino flux, is (2.2 $\pm$ 0.7) $\times$10$^{-39}$ cm$^2$ -- consistent with the standard model prediction. The neutron-number dependence of this result, together with that from our previous measurement on CsI, confirms the existence of the \cevns process and provides improved constraints on non-standard neutrino interactions.

preprint2021arXiv

The EXO-200 detector, part II: Auxiliary Systems

The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.

preprint2020arXiv

Bound on 3+1 active-sterile neutrino mixing from the first four-week science run of KATRIN

We report on the light sterile neutrino search from the first four-week science run of the KATRIN experiment in~2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are analyzed by a high-resolution MAC-E filter down to 40 eV below the endpoint at 18.57 keV. We consider the framework with three active neutrinos and one sterile neutrino of mass $m_{4}$. The analysis is sensitive to a fourth mass state $m^2_{4} \lesssim$ 1000 eV$^2$ and to active-to-sterile neutrino mixing down to $|U_{e4}|^2 \gtrsim 2\cdot10^{-2}$. No significant spectral distortion is observed and exclusion bounds on the sterile mass and mixing are reported. These new limits supersede the Mainz results and improve the Troitsk bound for $m^2_{4} <$ 30 eV$^2$. The reactor and gallium anomalies are constrained for $ 100 < Δ{m}^2_{41} < 1000$ eV$^2$.

preprint2020arXiv

COHERENT Collaboration data release from the first detection of coherent elastic neutrino-nucleus scattering on argon

Release of COHERENT collaboration data from the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on argon. This release corresponds with the results of "Analysis A" published in Akimov et al., arXiv:2003.10630 [nucl-ex]. Data is shared in a binned, text-based format representing both "signal" and "backgrounds" along with associated uncertainties such that the included data can be used to perform independent analyses. This document describes the contents of the data release as well as guidance on the use of the data. Included example code in C++ (ROOT) and Python show one possible use of the included data.

preprint2020arXiv

Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment

Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by $γ$ interactions from $^{228}$Th (2615~keV), $^{226}$Ra (1764~keV) and $^{60}$Co (1332~keV and 1173~keV) calibration sources, over a range of electric fields. The $W$-value that defines the recombination-independent energy scale is measured to be $11.5~\pm~0.5$~(syst.)~$\pm~0.1$~(stat.) eV. These data are also used to measure the recombination fluctuations in the number of electrons and photons produced by the calibration sources at the MeV-scale, which deviate from extrapolations of lower-energy data. Additionally, a semi-empirical model for the energy resolution of the detector is developed, which is used to constrain the recombination efficiency, i.e., the fraction of recombined electrons that result in the emission of a detectable photon. Detailed measurements of the absolute charge and light yields for MeV-scale electron recoils are important for predicting the performance of future neutrinoless double beta decay detectors.

preprint2020arXiv

Measurement of the Spectral Shape of the beta-decay of 137Xe to the Ground State of 137Cs in EXO-200 and Comparison with Theory

We report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden non-unique $β$-decay transition $^{137}\textrm{Xe}(7/2^-)\to\,^{137}\textrm{Cs}(7/2^+)$. The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultra-low background environment of EXO-200, together with dedicated source deployment and analysis procedures, allowed for collection of a pure sample of the decays, with an estimated signal-to-background ratio of more than 99-to-1 in the energy range from 1075 to 4175 keV. In addition to providing a rare and accurate measurement of the first-forbidden non-unique $β$-decay shape, this work constitutes a novel test of the calculated electron spectral shapes in the context of the reactor antineutrino anomaly and spectral bump.

preprint2020arXiv

Suppression of Penning discharges between the KATRIN spectrometers

The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)neutrino mass with a sensitivity of $0.2\textrm{ eV/c}^2$ (90$\%$ C.L.) by precisely measuring the endpoint region of the tritium $β$-decay spectrum. It uses a tandem of electrostatic spectrometers working as MAC-E (magnetic adiabatic collimation combined with an electrostatic) filters. In the space between the pre-spectrometer and the main spectrometer, an unavoidable Penning trap is created when the superconducting magnet between the two spectrometers, biased at their respective nominal potentials, is energized. The electrons accumulated in this trap can lead to discharges, which create additional background electrons and endanger the spectrometer and detector section downstream. To counteract this problem, "electron catchers" were installed in the beamline inside the magnet bore between the two spectrometers. These catchers can be moved across the magnetic-flux tube and intercept on a sub-ms time scale the stored electrons along their magnetron motion paths. In this paper, we report on the design and the successful commissioning of the electron catchers and present results on their efficiency in reducing the experimental background.

preprint2019arXiv

First operation of the KATRIN experiment with tritium

The determination of the neutrino mass is one of the major challenges in astroparticle physics today. Direct neutrino mass experiments, based solely on the kinematics of beta-decay, provide a largely model-independent probe to the neutrino mass scale. The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to directly measure the effective electron antineutrino mass with a sensitivity of 0.2 eV 90% CL. In this work we report on the first operation of KATRIN with tritium which took place in 2018. During this commissioning phase of the tritium circulation system, excellent agreement of the theoretical prediction with the recorded spectra was found and stable conditions over a time period of 13 days could be established. These results are an essential prerequisite for the subsequent neutrino mass measurements with KATRIN in 2019.

preprint2019arXiv

Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode

Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measured drift velocities and corresponding temperature coefficients respectively are $1.97 \pm 0.04$ mm/$μ$s and $(-0.69\pm0.05)$\%/K for liquid xenon, and $1.42 \pm 0.03$ mm/$μ$s and $(+0.11\pm0.01)$\%/K for gaseous xenon at 1.5 bar. In addition, we measure longitudinal diffusion coefficients of $25.7 \pm 4.6$ cm$^2$/s and $149 \pm 23$ cm$^2$/s, for liquid and gas, respectively. The quantum efficiency of the gold photocathode is studied at the photon energy of 4.73 eV in liquid and gaseous xenon, and vacuum. These charge transport properties and the behavior of photocathodes in a xenon environment are important in designing and calibrating future large scale noble liquid detectors.

preprint2016arXiv

Cosmogenic Backgrounds to 0νββ in EXO-200

As neutrinoless double-beta decay experiments become more sensitive and intrinsic radioactivity in detector materials is reduced, previously minor contributions to the background must be understood and eliminated. With this in mind, cosmogenic backgrounds have been studied with the EXO-200 experiment. Using the EXO-200 TPC, the muon flux (through a flat horizontal surface) underground at the Waste Isolation Pilot Plant (WIPP) has been measured to be Φ = 4.07 $\pm$ 0.14 (sys) $\pm$ 0.03 (stat) $\times$ $10^{-7}$cm$^{-2}$ s$^{-1}$, with a vertical intensity of $I_{v}$ = 2.97$^{+0.14}_{-0.13}$ (sys) $\pm$ 0.02 (stat) $\times$ $10^{-7}$cm$^{-2}$ s$^{-1}$ sr$^{-1}$. Simulations of muon-induced backgrounds identified several potential cosmogenic radionuclides, though only 137Xe is a significant background for the 136Xe 0νββ search with EXO-200. Muon-induced neutron backgrounds were measured using γ-rays from neutron capture on the detector materials. This provided a measurement of 137Xe yield, and a test of the accuracy of the neutron production and transport simulations. The independently measured rates of 136Xe neutron capture and of 137Xe decay agree within uncertainties. Geant4 and FLUKA simulations were performed to estimate neutron capture rates, and these estimates agreed to within ~40% or better with measurements. The ability to identify 136Xe(n,γ) events will allow for rejection of 137Xe backgrounds in future 0νββ analyses.

preprint2016arXiv

First Search for Lorentz and CPT Violation in Double Beta Decay with EXO-200

A search for Lorentz- and CPT-violating signals in the double beta decay spectrum of $^{136}$Xe has been performed using an exposure of 100 kg$\cdot$yr with the EXO-200 detector. No significant evidence of the spectral modification due to isotropic Lorentz-violation was found, and a two-sided limit of $-2.65 \times 10^{-5 } \; \textrm{GeV} < \mathring{a}^{(3)}_{\text{of}} < 7.60 \times 10^{-6} \; \textrm{GeV}$ (90% C.L.) is placed on the relevant coefficient within the Standard-Model Extension (SME). This is the first experimental study of the effect of the SME-defined oscillation-free and momentum-independent neutrino coupling operator on the double beta decay process.

preprint2015arXiv

Background Radiation Measurements at High Power Research Reactors

Research reactors host a wide range of activities that make use of the intense neutron fluxes generated at these facilities. Recent interest in performing measurements with relatively low event rates, e.g. reactor antineutrino detection, at these facilities necessitates a detailed understanding of background radiation fields. Both reactor-correlated and naturally occurring background sources are potentially important, even at levels well below those of importance for typical activities. Here we describe a comprehensive series of background assessments at three high-power research reactors, including $γ$-ray, neutron, and muon measurements. For each facility we describe the characteristics and identify the sources of the background fields encountered. The general understanding gained of background production mechanisms and their relationship to facility features will prove valuable for the planning of any sensitive measurement conducted therein.

preprint2015arXiv

Light Collection and Pulse-Shape Discrimination in Elongated Scintillator Cells for the PROSPECT Reactor Antineutrino Experiment

A meter-long, 23-liter EJ-309 liquid scintillator detector has been constructed to study the light collection and pulse-shape discrimination performance of elongated scintillator cells for the PROSPECT reactor antineutrino experiment. The magnitude and uniformity of light collection and neutron/gamma discrimination power in the energy range of antineutrino inverse beta decay products have been studied using gamma and spontaneous fission calibration sources deployed along the cell long axis. We also study neutron-gamma discrimination and light collection abilities for differing PMT and reflector configurations. Key design features for optimizing MeV-scale response and background rejection capabilities are identified.

preprint2015arXiv

The PROSPECT Physics Program

The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long distances. PROSPECT is conceived as a 2-phase experiment utilizing segmented $^6$Li-doped liquid scintillator detectors for both efficient detection of reactor antineutrinos through the inverse beta decay reaction and excellent background discrimination. PROSPECT Phase I consists of a movable 3-ton antineutrino detector at distances of 7 - 12 m from the reactor core. It will probe the best-fit point of the $ν_e$ disappearance experiments at 4$σ$ in 1 year and the favored region of the sterile neutrino parameter space at $>$3$σ$ in 3 years. With a second antineutrino detector at 15 - 19 m from the reactor, Phase II of PROSPECT can probe the entire allowed parameter space below 10 eV$^{2}$ at 5$σ$ in 3 additional years. The measurement of the reactor antineutrino spectrum and the search for short-baseline oscillations with PROSPECT will test the origin of the spectral deviations observed in recent $θ_{13}$ experiments, search for sterile neutrinos, and conclusively address the hypothesis of sterile neutrinos as an explanation of the reactor anomaly.

preprint2014arXiv

An improved measurement of the 2νββ half-life of Xe-136 with EXO-200

We report on an improved measurement of the 2νββ half-life of Xe-136 performed by EXO-200. The use of a large and homogeneous time projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data analysis methods used for double-beta decay searches with EXO-200, while emphasizing those directly related to the present measurement. The Xe-136 2νββ half-life is found to be 2.165 +- 0.016 (stat) +- 0.059 (sys) x 10^21 years. This is the most precisely measured half-life of any 2νββ decay to date.

preprint2014arXiv

Search for Majorana neutrinos with the first two years of EXO-200 data

Many extensions of the Standard Model of particle physics suggest that neutrinos should be Majorana-type fermions, but this assumption is difficult to confirm. Observation of neutrinoless double-beta decay ($0νββ$), a spontaneous transition that may occur in several candidate nuclei, would verify the Majorana nature of the neutrino and constrain the absolute scale of the neutrino mass spectrum. Recent searches carried out with $^{76}$Ge (GERDA experiment) and $^{136}$Xe (KamLAND-Zen and EXO-200 experiments) have established the lifetime of this decay to be longer than $10^{25}$ yr, corresponding to a limit on the neutrino mass of 0.2-0.4 eV. Here we report new results from EXO-200 based on 100 kg$\cdot$yr of $^{136}$Xe exposure, representing an almost fourfold increase from our earlier published datasets. We have improved the detector resolution at the $^{136}$Xe double-beta-decay Q-value to $σ$/E = 1.53% and revised the data analysis. The obtained half-life sensitivity is $1.9\cdot10^{25}$ yr, an improvement by a factor of 2.7 compared to previous EXO-200 results. We find no statistically significant evidence for $0νββ$ decay and set a half-life limit of $1.1\cdot10^{25}$ yr at 90% CL. The high sensitivity holds promise for further running of the EXO-200 detector and future $0νββ$ decay searches with nEXO.

preprint2014arXiv

Search for Majoron-emitting modes of double-beta decay of $^{136}$Xe with EXO-200

EXO-200 is a single phase liquid xenon detector designed to search for neutrinoless double-beta decay of $^{136}$Xe. Here we report on a search for various Majoron-emitting modes based on 100 kg$\cdot$yr exposure of $^{136}$Xe. A lower limit of $T^{^{136}Xe}_{1/2} >1.2 \cdot 10^{24}$ yr at 90% C.L. on the half-life of the spectral index = 1 Majoron decay was obtained, corresponding to a constraint on the Majoron-neutrino coupling constant of $|< g^{M}_{ee} >|<$ (0.8-1.7)$\cdot$10$^{-5}$.

preprint2014arXiv

Spectroscopy of Ba and Ba$^+$ deposits in solid xenon for barium tagging in nEXO

Progress on a method of barium tagging for the nEXO double beta decay experiment is reported. Absorption and emission spectra for deposits of barium atoms and ions in solid xenon matrices are presented. Excitation spectra for prominent emission lines, temperature dependence and bleaching of the fluorescence reveal the existence of different matrix sites. A regular series of sharp lines observed in Ba$^+$ deposits is identified with some type of barium hydride molecule. Lower limits for the fluorescence quantum efficiency of the principal Ba emission transition are reported. Under current conditions, an image of $\le10^4$ Ba atoms can be obtained. Prospects for imaging single Ba atoms in solid xenon are discussed.

preprint2012arXiv

Search for Neutrinoless Double-Beta Decay in $^{136}$Xe with EXO-200

We report on a search for neutrinoless double-beta decay of $^{136}$Xe with EXO-200. No signal is observed for an exposure of 32.5 kg-yr, with a background of ~1.5 x 10^{-3} /(kg yr keV) in the $\pm 1σ$ region of interest. This sets a lower limit on the half-life of the neutrinoless double-beta decay $T_{1/2}^{0νββ}$($^{136}$Xe) > 1.6 x 10$^{25}$ yr (90% CL), corresponding to effective Majorana masses of less than 140-380 meV, depending on the matrix element calculation.

preprint2012arXiv

The EXO-200 detector, part I: Detector design and construction

EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most innovative aspects of the design that revolve around the reduction of backgrounds, the efficient use of the expensive isotopically enriched xenon, and the optimization of the energy resolution in a relatively large volume.

preprint2011arXiv

A magnetically-driven piston pump for ultra-clean applications

A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon TPC of EXO-200. The pump, using sprung polymer gaskets, is capable of pumping more than 16 standard liters per minute (SLPM) of xenon gas with 750 torr differential pressure.

preprint2011arXiv

A xenon gas purity monitor for EXO

We discuss the design, operation, and calibration of two versions of a xenon gas purity monitor (GPM) developed for the EXO double beta decay program. The devices are sensitive to concentrations of oxygen well below 1 ppb at an ambient gas pressure of one atmosphere or more. The theory of operation of the GPM is discussed along with the interactions of oxygen and other impurities with the GPM's tungsten filament. Lab tests and experiences in commissioning the EXO-200 double beta decay experiment are described. These devices can also be used on other noble gases.

preprint2011arXiv

Observation of Two-Neutrino Double-Beta Decay in Xe-136 with EXO-200

We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Standard Model, has been observed for several nuclei but not for Xe-136. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrino-less double-beta decay, the most sensitive probe for the existence of Majorana particles and the measurement of the neutrino mass scale.

preprint2011arXiv

Xenon purity analysis for EXO-200 via mass spectrometry

We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We have used the technique to screen the EXO-200 xenon before, during, and after its use in our detector, and these measurements have proven useful. This is the first application of the cold trap mass spectrometry technique to an operating physics experiment.

preprint2010arXiv

A simple radionuclide-driven single-ion source

We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating 148Gd onto a silicon α-particle detector and vapor depositing a layer of BaF2 over it. 144Sm recoils from the alpha decay of 148Gd are used to dislodge Ba+ ions from the BaF2 layer and emit them in the surrounding environment. The simultaneous detection of an α particle in the substrate detector allows for tagging of the nuclear decay and of the Ba+ emission. The source is simple, durable, and can be manipulated and used in different environments. We discuss the fabrication process, which can be easily adapted to emit most other chemical species, and the performance of the source.

preprint2009arXiv

A Xenon Condenser with a Remote Liquid Storage Vessel

We describe the design and operation of a system for xenon liquefaction in which the condenser is separated from the liquid storage vessel. The condenser is cooled by a pulse tube cryocooler, while the vessel is cooled only by the liquid xenon itself. This arrangement facilitates liquid particle detector research by allowing easy access to the upper and lower flanges of the vessel. We find that an external xenon gas pump is useful for increasing the rate at which cooling power is delivered to the vessel, and we present measurements of the power and efficiency of the apparatus.

preprint2009arXiv

Characterization of large area APDs for the EXO-200 detector

EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169K - the temperature of liquid xenon. We also describe the individual characterization of more than 800 LAAPDs for selective installation in the EXO-200 detector.