Source author record

Y. Masuda

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

3works
3topics
4close collaborators

Published work

3 publications

preprint2022arXiv

Measurement of the Parity-Odd Angular Distribution of Gamma Rays From Polarized Neutron Capture on 35^{35}Cl

We report a measurement of two energy-weighted gamma cascade angular distributions from polarized slow neutron capture on the 35{}^{35}Cl nucleus, one parity-odd correlation proportional to sn⃗⋅kγ⃗\vec{s_{n}} \cdot \vec{k_γ} and one parity-even correlation proportional to sn⃗⋅kn⃗×kγ⃗\vec{s_{n}} \cdot \vec{k_{n}} \times \vec{k_γ}. A parity violating asymmetry can appear in this reaction due to the weak nucleon-nucleon (NN) interaction which mixes opposite parity S and P-wave levels in the excited compound 36^{36}Cl nucleus formed upon slow neutron capture. If parity-violating (PV) and parity-conserving (PC) terms both exist, the measured differential cross section can be related to them via dσdΩ∝1+Aγ,PVcos⁡θ+Aγ,PCsin⁡θ\frac{dσ}{dΩ}\propto1+A_{γ, PV}\cosθ+A_{γ,PC}\sinθ. The PV and PC asymmetries for energy-weighted gamma cascade angular distributions for polarized slow neutron capture on 35^{35}Cl averaged over the neutron energies from 2.27~meV to 9.53~meV were measured to be Aγ,PV=(−23.9±0.7)×10−6A_{γ,PV}=(-23.9\pm0.7)\times 10^{-6} and Aγ,PC=(0.1±0.7)×10−6A_{γ,PC}=(0.1\pm0.7)\times 10^{-6}. These results are consistent with previous experimental results. Systematic errors were quantified and shown to be small compared to the statistical error. These asymmetries in the angular distributions of the gamma rays emitted from the capture of polarized neutrons in 35^{35}Cl were used to verify the operation and data analysis procedures for the NPDGamma experiment which measured the parity-odd asymmetry in the angular distribution of gammas from polarized slow neutron capture on protons.

preprint2016arXiv

Measurement of spin-flip probabilities for ultracold neutrons interacting with nickel phosphorus coated surfaces

We report a measurement of the spin-flip probabilities for ultracold neutrons interacting with surfaces coated with nickel phosphorus. For 50~μμm thick nickel phosphorus coated on stainless steel, the spin-flip probability per bounce was found to be βNiP  on  SS=(3.3−5.6+1.8)×10−6β_{\rm NiP\;on\;SS} = (3.3^{+1.8}_{-5.6}) \times 10^{-6}. For 50~μμm thick nickel phosphorus coated on aluminum, the spin-flip probability per bounce was found to be βNiP  on  Al=(3.6−5.9+2.1)×10−6β_{\rm NiP\;on\;Al} = (3.6^{+2.1}_{-5.9}) \times 10^{-6}. For the copper guide used as reference, the spin flip probability per bounce was found to be βCu=(6.7−2.5+5.0)×10−6β_{\rm Cu} = (6.7^{+5.0}_{-2.5}) \times 10^{-6}. The results on the nickel phosphorus-coated surfaces may be interpreted as upper limits, yielding βNiP  on  SS<6.2×10−6β_{\rm NiP\;on\;SS} < 6.2 \times 10^{-6} (90\% C.L.) and βNiP  on  Al<7.0×10−6β_{\rm NiP\;on\;Al} < 7.0 \times 10^{-6} (90\% C.L.) for 50~μμm thick nickel phosphorus coated on stainless steel and 50~μμm thick nickel phosphorus coated on aluminum, respectively. Nickel phosphorus coated stainless steel or aluminum provides a solution when low-cost, mechanically robust, and non-depolarizing UCN guides with a high-Fermi-potential are needed.

preprint2004arXiv

A Current Mode Detector Array for Gamma-Ray Asymmetry Measurements

We have built a CsI(Tl) gamma-ray detector array for the NPDGamma experiment to search for a small parity-violating directional asymmetry in the angular distribution of 2.2 MeV gamma-rays from the capture of polarized cold neutrons by protons with a sensitivity of several ppb. The weak pion-nucleon coupling constant can be determined from this asymmetry. The small size of the asymmetry requires a high cold neutron flux, control of systematic errors at the ppb level, and the use of current mode gamma-ray detection with vacuum photo diodes and low-noise solid-state preamplifiers. The average detector photoelectron yield was determined to be 1300 photoelectrons per MeV. The RMS width seen in the measurement is therefore dominated by the fluctuations in the number of gamma rays absorbed in the detector (counting statistics) rather than the intrinsic detector noise. The detectors were tested for noise performance, sensitivity to magnetic fields, pedestal stability and cosmic background. False asymmetries due to gain changes and electronic pickup in the detector system were measured to be consistent with zero to an accuracy of 10−910^{-9} in a few hours. We report on the design, operating criteria, and the results of measurements performed to test the detector array.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.