Source author record

Y. -c. Ghim

Y. -c. Ghim appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2019arXiv

Deep neural network Grad-Shafranov solver constrained with measured magnetic signals

A neural network solving Grad-Shafranov equation constrained with measured magnetic signals to reconstruct magnetic equilibria in real time is developed. Database created to optimize the neural network's free parameters contain off-line EFIT results as the output of the network from $1,118$ KSTAR experimental discharges of two different campaigns. Input data to the network constitute magnetic signals measured by a Rogowski coil (plasma current), magnetic pick-up coils (normal and tangential components of magnetic fields) and flux loops (poloidal magnetic fluxes). The developed neural networks fully reconstruct not only the poloidal flux function $ψ\left( R, Z\right)$ but also the toroidal current density function $j_ϕ\left( R, Z\right)$ with the off-line EFIT quality. To preserve robustness of the networks against a few missing input data, an imputation scheme is utilized to eliminate the required additional training sets with large number of possible combinations of the missing inputs.

preprint2016arXiv

Reliability of the two-point measurement of the spatial correlation length from Gaussian-shaped fluctuating signals in fusion-grade plasmas

A statistical method for the estimation of spatial correlation lengths of Gaussian-shaped fluctuating signals with two measurement points is examined to quantitatively evaluate its reliability (variance) and accuracy (bias error). The standard deviation of the correlation value is analytically derived for randomly distributed Gaussian shaped fluctuations satisfying stationarity and homogeneity, allowing us to evaluate, as a function of fluctuation-to-noise ratios, sizes of averaging time windows and ratios of the distance between the two measurement points to the true correlation length, the goodness of the two-point measurement for estimating the spatial correlation length. Analytic results are confirmed with numerically generated synthetic data and real experimental data obtained with the KSTAR beam emission spectroscopy diagnostic. Our results can be applied to Gaussian-shaped fluctuating signals where a correlation length must be measured with only two measurement points.

preprint2015arXiv

Conditions for generating synthetic data to investigate characteristics of fluctuating quantities

Synthetic data describing coherent random fluctuations have widely been used to validate numerical sim- ulations against experimental observations or to examine the reliability of extracting statistical properties of plasma turbulence via correlation functions. Estimating correlation time or lengths based on correlation functions implicitly assumes that the observed data are stationary and homogeneous. It is, therefore, impor- tant that synthetic data also satisfy the stationary process and homogeneous state. Based on the synthetic data with randomly generated moving Gaussian shaped fluctuations both in time and space, the correlation function depending on the size of averaging time window is analytically derived. Then, the smallest possible spatial window size of synthetic data satisfying the stationary process and homogeneous state is proposed, thereby reducing the computation time to generate proper synthetic data and providing a constraint on the minimum size of simulation domains when using synthetic diagnostics to compare with experiment. This window size is also numerically confirmed with 1D synthetic data with various parameter scans.

preprint2015arXiv

Quantifying noise sources in the KSTAR 2014 Thomson Scattering system from the measured variation on electron temperature

With the Thomson scattering (TS) system in KSTAR, temporal evolution of electron temperature ($T_e$) is estimated using a weighted look-up table method with fast sampling ($1.25$ or $2.5$ GS/s) digitizers during the 2014 KSTAR campaign. Background noise level is used as a weighting parameter without considering the photon noise due to the absence of information on absolute photon counts detected by the TS system. Estimated electron temperature during a relatively quiescent discharge are scattered, i.e., $15$\% variation on $T_e$ with respect to its mean value. We find that this $15$\% variation on $T_e$ cannot be explained solely by the background noise level which leads us to include photon noise effects in our analysis. Using synthetic data, we have estimated the required photon noise level consistent with the observation and determined the dominant noise source in KSTAR TS system.

preprint2012arXiv

Calculation of spatial response of 2D BES diagnostic on MAST

The Beam Emission Spectroscopy (BES) turbulence diagnostic on MAST is to be upgraded in June 2010 from a 1D trial system to a 2D imaging system (8 radial \times 4 poloidal channels) based on a newly developed APD array camera. The spatial resolution of the new system is calculated in terms of the point spread function (PSF) to account for the effects of field-line curvature, observation geometry, the finite lifetime of the excited state of the beam atoms, and beam attenuation and divergence. It is found that the radial spatial resolution is ~ 2-3 cm and the poloidal spatial resolution ~ 1-5 cm depending on the radial viewing location. The absolute number of detected photons is also calculated, hence the photon noise level can be determined

preprint2012arXiv

Experimental Signatures of Critically Balanced Turbulence in MAST

Beam Emission Spectroscopy (BES) measurements of ion-scale density fluctuations in the MAST tokamak are used to show that the turbulence correlation time, the drift time associated with ion temperature or density gradients, the particle (ion) streaming time along the magnetic field and the magnetic drift time are consistently comparable, suggesting a "critically balanced" turbulence determined by the local equilibrium. The resulting scalings of the poloidal and radial correlation lengths are derived and tested. The nonlinear time inferred from the density fluctuations is longer than the other times; its ratio to the correlation time scales as $ν_{*i}^{-0.8\pm0.1}$, where $ν_{*i}=$ ion collision rate/streaming rate. This is consistent with turbulent decorrelation being controlled by a zonal component, invisible to the BES, with an amplitude exceeding the drift waves' by $\sim ν_{*i}^{-0.8}$.

preprint2012arXiv

Experimental verification of Boltzmann equilibrium for negative ions in weakly collisional electronegative plasmas

Weakly collisional Ar-O2 electronegative plasmas are investigated in a dc multidipole chamber. An electronegative core and an electropositive halo are observed. The density ratio of negative ions to electrons (α) in the nondrifting bulk is found to be 0.43. The profile of α is found using both the phase velocity of ion acoustic waves and the drift velocity of positive ions determined by laser induced fluorescence. The experiment shows that negative ions are in Boltzmann equilibrium with a temperature of 0.06 \pm 0.02 eV. Double layers are not found separating the electronegative core and the electropositive halo.

preprint2012arXiv

Local dependence of ion temperature gradient on magnetic configuration, rotational shear and turbulent heat flux in MAST

Experimental data from the Mega Amp Spherical Tokamak (MAST) is used to show that the inverse gradient scale length of the ion temperature R/LTi (normalized to the major radius R) has its strongest local correlation with the rotational shear and the pitch angle of the magnetic field (or, equivalently, an inverse correlation with q/ε, the safety factor/the inverse aspect ratio). Furthermore, R/LTi is found to be inversely correlated with the gyro-Bohm-normalized local turbulent heat flux estimated from the density fluctuation level measured using a 2D Beam Emission Spectroscopy (BES) diagnostic. These results can be explained in terms of the conjecture that the turbulent system adjusts to keep R/LTi close to a certain critical value (marginal for the excitation of turbulence) determined by local equilibrium parameters (although not necessarily by linear stability).

preprint2012arXiv

Measurement and physical interpretation of the mean motion of turbulent density patterns detected by the BES system on MAST

The mean motion of turbulent patterns detected by a two-dimensional (2D) beam emission spectroscopy (BES) diagnostic on the Mega Amp Spherical Tokamak (MAST) is determined using a cross-correlation time delay (CCTD) method. Statistical reliability of the method is studied by means of synthetic data analysis. The experimental measurements on MAST indicate that the apparent mean poloidal motion of the turbulent density patterns in the lab frame arises because the longest correlation direction of the patterns (parallel to the local background magnetic fields) is not parallel to the direction of the fastest mean plasma flows (usually toroidal when strong neutral beam injection is present). The experimental measurements are consistent with the mean motion of plasma being toroidal. The sum of all other contributions (mean poloidal plasma flow, phase velocity of the density patterns in the plasma frame, non-linear effects, etc.) to the apparent mean poloidal velocity of the density patterns is found to be negligible. These results hold in all investigated L-mode, H-mode and internal transport barrier (ITB) discharges. The one exception is a high-poloidal-beta (the ratio of the plasma pressure to the poloidal magnetic field energy density) discharge, where a large magnetic island exists. In this case BES detects very little motion. This effect is currently theoretically unexplained.