Researcher profile

Xufang Li

Xufang Li contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

Quasi-periodic oscillations of the X-ray burst from the magnetar SGR J1935+2154 and associated with the fast radio burst FRB 200428

The origin(s) and mechanism(s) of fast radio bursts (FRBs), which are short radio pulses from cosmological distances, have remained a major puzzle since their discovery. We report a strong Quasi-Periodic Oscillation(QPO) of 40 Hz in the X-ray burst from the magnetar SGR J1935+2154 and associated with FRB 200428, significantly detected with the Hard X-ray Modulation Telescope (Insight-HXMT) and also hinted by the Konus-Wind data. QPOs from magnetar bursts have only been rarely detected; our 3.4 sigma (p-value is 2.9e-4) detection of the QPO reported here reveals the strongest QPO signal observed from magnetars (except in some very rare giant flares), making this X-ray burst unique among magnetar bursts. The two X-ray spikes coinciding with the two FRB pulses are also among the peaks of the QPO. Our results suggest that at least some FRBs are related to strong oscillation processes of neutron stars. We also show that we may overestimate the significance of the QPO signal and underestimate the errors of QPO parameters if QPO exists only in a fraction of the time series of a X-ray burst which we use to calculate the Leahy-normalized periodogram.

preprint2021arXiv

In-orbit timing calibration of the Insight-Hard X-ray Modulation Telescope

We describe the timing system and the timing calibration results of the three payloads on-board the Insight-Hard X-ray Modulation Telescope (Insight-HXMT). These three payloads are the High Energy X-ray telescope (HE, 20-250 keV), the Medium Energy X-ray telescope (ME, 5-30 keV) and the low Energy X-ray telescope (LE, 1-10 keV). We present a method to correct the temperature-dependent period response and the long-term variation of the on-board crystal oscillator, especially for ME that does not carry a temperature-compensated crystal oscillator. The time of arrivals (ToAs) of the Crab pulsar are measured to evaluate the accuracy of the timing system. As the ephemeris of the Crab pulsar given by Jodrell Bank observatory has systematic errors around 40 μs (Rots et al. 2014), we use the quasi-simultaneous observations of the X-ray Timing Instrument (XTI) on-board the Neutron star Interior Composition Explorer (NICER) to produce the Crab ephemerides and to verify the timing system of Insight-HXMT. The energy-dependent ToAs' offsets relative to the NICER measurements including physical and instrumental origins are about 24.7μs, 10.1μs and 864.7μs, and the systematic errors of the timing system are determined as 12.1μs, 8.6μs, and 15.8μs, for HE, ME and LE respectively.

preprint2021arXiv

The design of the Ali CMB Polarization Telescope receiver

Ali CMB Polarization Telescope (AliCPT-1) is the first CMB degree-scale polarimeter to be deployed on the Tibetan plateau at 5,250m above sea level. AliCPT-1 is a 90/150 GHz 72 cm aperture, two-lens refracting telescope cooled down to 4 K. Alumina lenses, 800mm in diameter, image the CMB in a 33.4° field of view on a 636mm wide focal plane. The modularized focal plane consists of dichroic polarization-sensitive Transition-Edge Sensors (TESes). Each module includes 1,704 optically active TESes fabricated on a 150mm diameter silicon wafer. Each TES array is read out with a microwave multiplexing readout system capable of a multiplexing factor up to 2,048. Such a large multiplexing factor has allowed the practical deployment of tens of thousands of detectors, enabling the design of a receiver that can operate up to 19 TES arrays for a total of 32,376 TESes. AliCPT-1 leverages the technological advancements in the detector design from multiple generations of previously successful feedhorn-coupled polarimeters, and in the instrument design from BICEP-3, but applied on a larger scale. The cryostat receiver is currently under integration and testing. During the first deployment year, the focal plane will be populated with up to 4 TES arrays. Further TES arrays will be deployed in the following years, fully populating the focal plane with 19 arrays on the fourth deployment year. Here we present the AliCPT-1 receiver design, and how the design has been optimized to meet the experimental requirements.

preprint2020arXiv

Design and Calibration of the High Energy Particle Monitor onboard the Insight-HXMT

Three high energy particle monitors (HPMs) employed onboard the Hard X-ray Modulation Telescope Insight-HXMT) can detect the charged particles from South Atlantic Anomaly (SAA) and hence provide the alert trigger for switch-on/off of the main detectors. Here a typical design of HPM with high stability and reliability is adopted by taking a plastic scintillator coupled with a small photomultiplier tube (PMT). The window threshold of HPM is designed as 1 MeV and 20 MeV for the incident electron and proton, respectively. Before the launch of Insight-HXMT, we performed in details the ground calibration of HPM. The measured energy response and its dependence on temperature are taken as essential input of Geant4 simulation for estimating the HPM count rate given with an incident particle energy spectrum. This serves as a guidance for choosing a reasonable working range of the PMT high voltage once the real SAA count rate is measured by HPM in orbit. So far the three HPMs have been working in orbit for more than two years. Apart from providing reliable alert trigger, the HPMs data are used as well to map the SAA region.

preprint2020arXiv

In-flight calibration of the Insight-Hard X-ray Modulation Telescope

We present the calibration of the Insight-Hard X-ray Modulation Telescope (Insight-HXMT) X-ray satellite, which can be used to perform timing and spectral studies of bright X-ray sources. Insight-HXMT carries three main payloads onboard: the High Energy X-ray telescope (HE), the Medium Energy X-ray telescope (ME) and the Low Energy X-ray telescope (LE). In orbit, the radioactive sources, activated lines, the fluorescence lines and celestial sources are used to calibrate the energy scale and energy resolution of the payloads. The Crab nebular is adopted as the primary effective area calibrator and empirical functions are constructed to modify the simulated effective areas of the three payloads respectively. The systematic errors of HE, compared to the model of the Crab nebular, are less than 2% in 28--120 keV and 2%--10% above 120 keV. The systematic errors of ME are less than 1.5% in 10--35 keV. The systematic errors of LE are less than 1% in 1--7 keV except the Si K--edge (1.839 keV, up to 1.5%) and less than 2% in 7--10 keV.

preprint2019arXiv

In-orbit calibration status of the Insight-HXMT

As China's first X-ray astronomical satellite, Insight-HXMT (Hard X-ray Modulation Telescope) successfully launched on Jun 15, 2017. It performs timing and spectral studies of bright sources to determine their physical parameters. HXMT carries three main payloads onboard: the High Energy X-ray telescope (HE, 20-250 keV, NaI(Tl)/CsI(Na)), the Medium Energy X-ray Telescope (ME, 5-30 keV, Si-Pin) and the Low Energy X-ray telescope (LE, 1-15 keV, SCD). In orbit, we have used the radioactive sources, activated lines, the fluorescence line, and Cas A to calibrate the gain and energy resolution of the payloads. The Crab pulsar was adopted as the primary effective area calibrator and an empirical function was found to modify the simulated effective areas. The absolute timing accuracy of HXMT is about 100us from the TOA of Crab Pulsar.

preprint2019arXiv

Overview to the Hard X-ray Modulation Telescope (Insight-HXMT) Satellite

As China's first X-ray astronomical satellite, the Hard X-ray Modulation Telescope (HXMT), which was dubbed as Insight-HXMT after the launch on June 15, 2017, is a wide-band (1-250 keV) slat-collimator-based X-ray astronomy satellite with the capability of all-sky monitoring in 0.2-3 MeV. It was designed to perform pointing, scanning and gamma-ray burst (GRB) observations and, based on the Direct Demodulation Method (DDM), the image of the scanned sky region can be reconstructed. Here we give an overview of the mission and its progresses, including payload, core sciences, ground calibration/facility, ground segment, data archive, software, in-orbit performance, calibration, background model, observations and some preliminary results.