Researcher profile

Xiaoliang Zhang

Xiaoliang Zhang contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2025arXiv

A Dual-Tuned Concentric Multimodal RF Coil for 7T 1H/31P MRSI: Concurrently Enhancing B1 Efficiency Over Single-Tuned References

This study presents the design, simulation, and experimental validation of a dual-tuned concentric multimodal surface coil for 7T 1H/31P magnetic resonance spectroscopic imaging (MRSI), developed to significantly enhance 31P B1 efficiency while improving 1H performance. The coil architecture utilizes two interleaved sets of three concentric loop resonators. Intra-nucleus electromagnetic coupling within each three-loop set generates a spectrum of eigenmodes; the operational modes for 1H and 31P were specifically selected because their co-directed current distributions reinforce the magnetic field at the center, yielding B1 patterns that resemble those of conventional single-loop surface coils but with superior efficiency. Full-wave electromagnetic simulations and bench measurements on a fabricated prototype were conducted to characterize the multimodal resonance behavior, scattering parameters, B1 distribution, and 10-g local SAR, using size-matched conventional single-tuned loops as references. The results confirmed that the design reproducibly generated the predicted eigenmode ordering with sufficient spectral separation to prevent interference from parasitic or undesired modes. Notably, the multimodal design achieved an 83% boost in 31P B1 efficiency and a 21% boost in 1H B1 efficiency at the coil center compared to same-sized single-tuned references. Sufficient inter-nuclear decoupling was achieved to prevent signal leakage between channels, and simulations with a human head model confirmed that the peak 10-g local SAR remained comparable to conventional designs. These findings demonstrate that this multimodal concentric design offers a robust and highly efficient solution for multinuclear MRSI at ultrahigh fields, effectively mitigating the sensitivity limitations of X-nuclei without compromising proton-based imaging capabilities.

preprint2023arXiv

Multimodal surface coils for low-field MR imaging

Leveraging the potential of low-field Magnetic Resonance Imaging (MRI), our study introduces the multimodal surface RF coil, a design tailored to overcome the limitations of conventional coils in this context. The inherent challenges of low-field MRI, notably suboptimal signal-to-noise ratio (SNR) and the need for specialized RF coils, are effectively addressed by our novel design. The multimodal surface coil is characterized by a unique assembly of resonators, optimized for both B1 efficiency and low-frequency tuning capabilities, essential for low-field applications. This paper provides a thorough investigation of the conceptual framework, design intricacies, and bench test validation of the multimodal surface coil. Through detailed simulations and comparative analyses, we demonstrate its superior performance in terms of B1 field efficiency, outperforming conventional surface coils.

preprint2022arXiv

A Multichannel RF Transceiver Array with mixed L-C loop and microstrip elements for Foot/Ankle MR Imaging at 7T

It is technically challenging to design efficient transceiver coil arrays for foot and ankle imaging at ultrahigh fields due to the irregular geometry of the anatomy. Shortened wavelength because of the high operation frequency at ultrahigh fields increases phase variation, leading to inhomogeneous B1 distribution in the imaging sample. In this work, we propose a hybrid design with mixed L-C loops and microstrip resonators for multichannel foot/ankle transceiver arrays at the ultrahigh field of 7T. The proposed transceiver array consists of 14 microstrip resonators and 5 L-C loop coils to cover the entire region of interest of the irregular-shaped foot/ankle with a relatively uniform B1 distribution at 7T. The feasibility and field behavior of the proposed design are systematically investigated numerically.

preprint2022arXiv

Accessing negative Poisson`s ratio of graphene by machine learning interatomic potentials

The negative Poisson`s ratio (NPR) is a novel property of materials, which enhances the mechanical feature and creates a wide range of application prospects in lots of fields, such as aerospace, electronics, medicine, etc. Fundamental understanding on the mechanism underlying NPR plays an important role in designing advanced mechanical functional materials. However, with different methods used, the origin of NPR is found different and conflicting with each other, for instance, in the representative graphene. In this study, based on machine learning technique, we constructed a moment tensor potential (MTP) for molecular dynamics (MD) simulations of graphene. By analyzing the evolution of key geometries, the increase of bond angle is found to be responsible for the NPR of graphene instead of bond length. The results on the origin of NPR are well consistent with the start-of-art first-principles, which amend the results from MD simulations using classic empirical potentials. Our study facilitates the understanding on the origin of NPR of graphene and paves the way to improve the accuracy of MD simulations being comparable to first-principle calculations. Our study would also promote the applications of machine learning interatomic potentials in multiscale simulations of functional materials. *Author

preprint2022arXiv

Design of a 13-Channel Hybrid Array System for Foot/Ankle Magnetic Resonance Imaging at 7T/300MHz

Microstrip lines are being used in MR applications due to their unique properties, such as reduced radiation loss, high-frequency capability, and reduced perturbation of sample loading to the RF coil compared to conventional coils. Here, we present the design of the 13-channel hybrid array consisting of 12 Microstrips, 1 volume half birdcage coil placed on the foot/ankle phantom, and high permittivity materials to cover the maximum area of the subject at 7T/300MHz. We demonstrate using electromagnetic simulations, magnetic field distribution, SAR performance, and the coupling performance of the array elements. This work provides an ultrahigh field multichannel RF solution to lower extremity MR imaging with excellent imaging coverage and field uniformity.

preprint2022arXiv

High Dielectric Sheet to reduce Electric Fields and Flatten Magnetic Fields in Self-decoupled Radiofrequency coils for MR Imaging

High impedance RF coils, such as self-decoupled coils, reduce the electromagnetic coupling between the coil elements and eliminates the use of complex decoupling technologies. Although the high impedance design promises excellent decoupling between the coil elements, it also results in high electric fields across the RF coil, leading to potential safety problems during imaging. It also causes B1 field asymmetry, ultimately leading to difficulties in imaging quantification. In this study, we propose and investigate using a high dielectric sheet to reduce the electric fields across the coil and achieve excellent electromagnetic decoupling among the coil elements, thereby ensuring safer MRI at ultra-high fields and maintaining high imaging performance.

preprint2020arXiv

An open boundary condition for high-order solutions of magnetohydrodynamics on unstructured grids

In this paper a characteristics-based open boundary condition (CBC) is proposed for the magnetohydrodynamic (MHD) system of equations. The algorithm is carefully designed and implemented in the context of a high-order flux reconstruction (FR) scheme under the Generalized Lagrange Multiplier (GLM)-MHD system of equations. It is implemented by adding the contribution of the characteristic equation directly to the corrected flux term in the FR scheme dispensing with solving time-dependent characteristic equations along boundary faces. The CBC method is shown to be more accurate and robust than commonly used zero normal derivative (ZND) and approximate Riemann solver boundary conditions (ARBC) in solving 1D, 2D, and 3D test problems. The CBC method is successfully applied to simulate challenging problems of magnetic reconnection for which other options failed to get stable results over long-period time integration.