Researcher profile

Leslie Ying

Leslie Ying contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

A Multichannel RF Transceiver Array with mixed L-C loop and microstrip elements for Foot/Ankle MR Imaging at 7T

It is technically challenging to design efficient transceiver coil arrays for foot and ankle imaging at ultrahigh fields due to the irregular geometry of the anatomy. Shortened wavelength because of the high operation frequency at ultrahigh fields increases phase variation, leading to inhomogeneous B1 distribution in the imaging sample. In this work, we propose a hybrid design with mixed L-C loops and microstrip resonators for multichannel foot/ankle transceiver arrays at the ultrahigh field of 7T. The proposed transceiver array consists of 14 microstrip resonators and 5 L-C loop coils to cover the entire region of interest of the irregular-shaped foot/ankle with a relatively uniform B1 distribution at 7T. The feasibility and field behavior of the proposed design are systematically investigated numerically.

preprint2022arXiv

Design of a 13-Channel Hybrid Array System for Foot/Ankle Magnetic Resonance Imaging at 7T/300MHz

Microstrip lines are being used in MR applications due to their unique properties, such as reduced radiation loss, high-frequency capability, and reduced perturbation of sample loading to the RF coil compared to conventional coils. Here, we present the design of the 13-channel hybrid array consisting of 12 Microstrips, 1 volume half birdcage coil placed on the foot/ankle phantom, and high permittivity materials to cover the maximum area of the subject at 7T/300MHz. We demonstrate using electromagnetic simulations, magnetic field distribution, SAR performance, and the coupling performance of the array elements. This work provides an ultrahigh field multichannel RF solution to lower extremity MR imaging with excellent imaging coverage and field uniformity.

preprint2020arXiv

Deep Low-rank Prior in Dynamic MR Imaging

The deep learning methods have achieved attractive performance in dynamic MR cine imaging. However, all of these methods are only driven by the sparse prior of MR images, while the important low-rank (LR) prior of dynamic MR cine images is not explored, which limits the further improvements on dynamic MR reconstruction. In this paper, a learned singular value thresholding (Learned-SVT) operation is proposed to explore deep low-rank prior in dynamic MR imaging for obtaining improved reconstruction results. In particular, we come up with two novel and distinct schemes to introduce the learnable low-rank prior into deep network architectures in an unrolling manner and a plug-and-play manner respectively. In the unrolling manner, we put forward a model-based unrolling sparse and low-rank network for dynamic MR imaging, dubbed SLR-Net. The SLR-Net is defined over a deep network flow graph, which is unrolled from the iterative procedures in the Iterative Shrinkage-Thresholding Algorithm (ISTA) for optimizing a sparse and low-rank based dynamic MRI model. In the plug-and-play manner, we present a plug-and-play LR network module that can be easily embedded into any other dynamic MR neural networks without changing the network paradigm. Experimental results show that both schemes can further improve the state-of-the-art CS methods, such as k-t SLR, and sparsity-driven deep learning-based methods, such as DC-CNN and CRNN, both qualitatively and quantitatively.

preprint2020arXiv

Kernel Bi-Linear Modeling for Reconstructing Data on Manifolds: The Dynamic-MRI Case

This paper establishes a kernel-based framework for reconstructing data on manifolds, tailored to fit the dynamic-(d)MRI-data recovery problem. The proposed methodology exploits simple tangent-space geometries of manifolds in reproducing kernel Hilbert spaces and follows classical kernel-approximation arguments to form the data-recovery task as a bi-linear inverse problem. Departing from mainstream approaches, the proposed methodology uses no training data, employs no graph Laplacian matrix to penalize the optimization task, uses no costly (kernel) pre-imaging step to map feature points back to the input space, and utilizes complex-valued kernel functions to account for k-space data. The framework is validated on synthetically generated dMRI data, where comparisons against state-of-the-art schemes highlight the rich potential of the proposed approach in data-recovery problems.

preprint2019arXiv

Bi-Linear Modeling of Data Manifolds for Dynamic-MRI Recovery

This paper puts forth a novel bi-linear modeling framework for data recovery via manifold-learning and sparse-approximation arguments and considers its application to dynamic magnetic-resonance imaging (dMRI). Each temporal-domain MR image is viewed as a point that lies onto or close to a smooth manifold, and landmark points are identified to describe the point cloud concisely. To facilitate computations, a dimensionality reduction module generates low-dimensional/compressed renditions of the landmark points. Recovery of the high-fidelity MRI data is realized by solving a non-convex minimization task for the linear decompression operator and those affine combinations of landmark points which locally approximate the latent manifold geometry. An algorithm with guaranteed convergence to stationary solutions of the non-convex minimization task is also provided. The aforementioned framework exploits the underlying spatio-temporal patterns and geometry of the acquired data without any prior training on external data or information. Extensive numerical results on simulated as well as real cardiac-cine and perfusion MRI data illustrate noteworthy improvements of the advocated machine-learning framework over state-of-the-art reconstruction techniques.