Source author record

Xiaoli Tang

Xiaoli Tang appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2021arXiv

Spin wave propagation in uniform waveguide: effects, modulation and its application

With the advent of the post-Moore era, researches on beyond-Complementary Metal Oxide Semiconductor (CMOS) approaches have been attracted more and more attention. Magnonics, or spin wave is one of the most promising technology beyond CMOS, which magnons-quanta for spin waves-process the information analogous to electronic charges in electronics. Information transmission by spin waves, which uses the frequency, amplitude and (or) phase to encode information, has a great many of advantages such as extremely low energy loss and wide-band frequency. Moreover, using the nonlinear characteristics of spin waves for information transmission can increase the extra degree of freedom of information. This review provides a tutorial overview over the effects of spin wave propagation and recent research progress in uniform spin wave waveguide. The propagation characteristics of spin waves in uniform waveguides and some special propagation phenomena such as spin wave beam splitting and self-focusing are described by combining experimental phenomena and theoretical formulas. Furthermore, we summarize methods for modulating propagation of spin wave in uniform waveguide, and comment on the advantages and limitations of these methods. The review may promote the development of information transmission technology based on spin waves.

preprint2020arXiv

Paper-Patent Citation Linkages as Early Signs for Predicting Delayed Recognized Knowledge: Macro and Micro Evidence

In this study, we investigate the extent to which patent citations to papers can serve as early signs for predicting delayed recognized knowledge in science using a comparative study with a control group, i.e., instant recognition papers. We identify the two opposite groups of papers by the Bcp measure, a parameter-free index for identifying papers which were recognized with delay. We provide a macro (Science/Nature papers dataset) and micro (a case chosen from the dataset) evidence on paper-patent citation linkages as early signs for predicting delayed recognized knowledge in science. It appears that papers with delayed recognition show a stronger and longer technical impact than instant recognition papers. We provide indication that in the more recent years papers with delayed recognition are awakened more often and earlier by a patent rather than by a scientific paper (also called "prince"). We also found that patent citations seem to play an important role to avoid instant recognition papers to level off or to become a so called "flash in the pan", i.e., instant recognition. It also appears that the sleeping beauties may firstly encounter negative citations and then patent citations and finally get widely recognized. In contrast to the two focused fields (biology and chemistry) for instant recognition papers, delayed recognition papers are rather evenly distributed in biology, chemistry, psychology, geology, materials science, and physics. We discovered several pairs of "science sleeping"-"technology [...]. We propose in further research to discover the potential ahead of time and transformative research by using citation delay analysis, patent & NPL analysis, and citation context analysis.

preprint2019arXiv

Bias-free reconfigurable magnonic phase shifter based on a spin-current controlled ferromagnetic resonator

Controllable phase modulation plays a pivotal role in the researches of magnonic logic gates. Here we propose a reconfigurable spin-current controlled magnonic phase shifter based on a ferromagnetic resonator. The proposed phase shifter requires no magnetic bias field during operation. The device is directly configured over the waveguide while keeping the original structure of the waveguide unaffected. Numerical micromagnetic simulations show that the phase shifter could yield either a π-phase or no shift depending on the magnetization status of the resonator, which can be controlled by a current pulse. Moreover, the phase-shifting operation could be affected by spin current. At different input current density, the device could be either used as a dynamic controlled phase shifter or a spin-wave valve. Finally, a XNOR magnonic logic gate is demonstrated using the proposed phase shifter. Our work can be a beneficial step to enhance the functionality and compatibility of the magnonic logic circuits.

preprint2015arXiv

The Effects of Research Level and Article Type on the Differences between Citation Metrics and F1000 Recommendations

F1000 recommendations have been validated as a potential data source for research evaluation, but reasons for differences between F1000 Article Factor (FFa scores) and citations remain to be explored. By linking 28254 publications in F1000 to citations in Scopus, we investigated the effect of research level and article type on the internal consistency of assessments based on citations and FFa scores. It turns out that research level has little impact, while article type has big effect on the differences. These two measures are significantly different for two groups: non-primary research or evidence-based research publications are more highly cited rather than highly recommended, however, translational research or transformative research publications are more highly recommended by faculty members but gather relatively lower citations. This can be expected because citation activities are usually practiced by academic authors while the potential for scientific revolutions and the suitability for clinical practice of an article should be investigated from the practitioners' points of view. We conclude with a policy relevant recommendation that the application of bibliometric approaches in research evaluation procedures should include the proportion of three types of publications: evidence-based research, transformative research, and translational research. The latter two types are more suitable to be assessed through peer review.

preprint2014arXiv

Dynamic control of spin wave spectra using spin-polarized currents

We describe a method of controlling the spin wave spectra dynamically in a uniform nanostripe waveguide through spin-polarized currents. A stable periodic magnetization structure is observed when the current flows vertically through the center of nanostripe waveguide. After being excited, the spin wave is transmitted at the sides of the waveguide. Numerical simulations of spin-wave transmission and dispersion curves reveal a single, pronounced band gap. Moreover, the periodic magnetization structure can be turned on and off by the spin-polarized current. The switching process from full rejection to full transmission takes place within less than 3ns. Thus, this type magnonic waveguide can be utilized for low-dissipation spin wave based filters.

preprint2009arXiv

A feasibility study of treatment verification using EPID cine images for hypofractionated lung radiotherapy

We propose a novel approach for potential on-line treatment verification using cine EPID (Electronic Portal Imaging Device) images for hypofractionated lung radiotherapy based on a machine learning algorithm. Hypofractionated radiotherapy requires high precision. It is essential to effectively monitor the target to ensure that the tumor is within the beam aperture. We modeled the treatment verification problem as a two-class classification problem and applied an Artificial Neural Network (ANN) to classify the cine EPID images acquired during the treatment into corresponding classes with the tumor inside or outside of the beam aperture. Training samples were generated for the ANN using digitally reconstructed radiographs (DRRs) with artificially added shifts in tumor location to simulate cine EPID images with different tumor locations. Principal Component Analysis (PCA) was used to reduce the dimensionality of the training samples and cine EPID images acquired during the treatment. The proposed treatment verification algorithm was tested on five hypofractionated lung patients in a retrospective fashion. On average, our proposed algorithm achieved a 98.0% classification accuracy, a 97.6% recall rate, and a 99.7% precision rate.