Researcher profile

Xiaokun Zhao

Xiaokun Zhao contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

An FPGA Based energy correction method for one-to-one coupled PET detector: model and evaluation

A PET scanner based on silicon photomultipliers (SiPMs) has been widely used as an advanced nuclear medicine imaging technique that yields quantitative images of regional in vivo biology and biochemistry. The compact size of the SiPM allows direct one to one coupling between the scintillation crystal and the photosensor, yielding better timing and energy resolutions than the light sharing methods that have to be used in photomultiplier tube (PMT) PET systems. To decrease the volume of readout electronics, a front end multiplexer with position decoder is a common choice for the one to one system without a highly integrated application specific integrated circuit (ASIC). However, in this case we cannot measure each crystal's deposited energy inspired by an annihilation photon, so the inter-crystal scatter (ICS) events will lead to the crystal mispositioning and then deteriorate the detector intrinsic resolution. Besides, considering the events rejection within the energy window resulting from the gain dispersion and nonlinear outputs of the SiPMs, an energy correction mechanism is needed. Yet, lack of the information of each crystal's energy will introduce large energy correction error for the ICS events. For this issue, an online energy correction mechanism implemented on a Kintext-7 Field Programmable Gate Array (FPGA) device is presented in this paper. Experiments in the laboratory were performed using an 8 x 8 segmented LYSO crystals coupled with an 8 x 8 SiPM (J-series, from ON Semiconductor) array which is under 22Na point source excitation. Test results indicate that both the energy of the non-ICS and ICS events can be precisely corrected and the energy resolution is better than 12 %. We also applied this method to an actual clinical PET scanner under a 68Ge line source to verify its multi-channel reliability.

preprint2022arXiv

The design of a time-interleaved analog-digital conversion modulator based on FPGA-TDC for PET application

Fully Field Programmable Gate Array (FPGA)based digitizer for high-resolution time and energy measurement is an attractive low cost solution for the readout electronics in positron emission computed tomography (PET)detector. In recent years, the FPGA based time-digital converter (FPGA-TDC) has been widely used for time measurement in the commercial PET scanners. Yet, for the energy measurement, few studies have been reported on a fully FPGA based, large dynamic range and high resolution alternative to the commercial analog-digital converter (ADC). Our previous research presents a 25 Ms/s FPGA-TDC based free-running ADC (FPGA-ADC), and successfully employed it in the readout electronics for PET detector. In this work-in-progress study, by means of the time-interleaved strategy, a 50 Ms/s FPGA-ADC is presented. With only two off-chip resistors, both the A/D conversion and energy measurement are achieved on a Xilinx Kintex-7 FPGA. Therefore, this method has great advantages inimproving system integration. Initial performance tests are also presented, and we hope it can give us a possibility to develop a new FPGA-only front-end digitizer for PET in future.