Source author record

Xiaobo Xue

Xiaobo Xue appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2015arXiv

Ultralong Faraday laser as an optical frequency standard

In this letter, we introduce the concept and experimentally demonstrate an ultralong Faraday laser as an optical frequency standard in principle. The ultralong Faraday laser is based on the Faraday anomalous dispersion optical filter (FADOF) with ultra-narrow bandwidth and the ultralong fiber extended cavity of $800$ m. The ultra-narrow FADOF is based on atomic transition line of isotope $^{87}$Rb, which has an ultra-narrow bandwidth of $26.0$ MHz and a transmission of $23.6\%$ at $780$ nm. Fibers of length $150$ m and $800$ m are used as ultralong fiber extended cavities, which provide optical feedback and give extremely small FSR of $0.667$ MHz and $0.125$ MHz, respectively. The mechanism of the proposed ultralong Faraday laser is to combine FADOF's ultra-narrow bandwidth and ultralong cavity's small free spectral range to limit the lasing frequency within FADOF bandwidth covered by the semiconductor gain. The active lasing frequency of the ultralong Faraday laser is determined by the center frequency of FADOF transmission, which is corresponding to atomic transition $5^{2}S_{1/2},\ F = 2 \ \rightarrow\ 5^{2}P_{3/2},\ F^{\prime} = 2,\ 3$ of isotope $^{87}$Rb. The Allan deviation of the fractional frequency of the ultralong Faraday laser output signal in 0.1 s -- 1 s measuring time is around $1\times10^{-11}$.

preprint2014arXiv

Hanle detection for optical clocks

Considering the strong inhomogeneous spatial polarization and intensity distribution of spontaneous decay fluorescence due to the Hanle effect, we propose and demonstrate a universe Hanle detection configuration of electron-shelving method for optical clocks. Experimental results from Ca atomic beam optical frequency standard with 423 nm electron-shelving method show that a designed Hanle detection geometry with optimized magnetic field direction, detection laser beam propagation and polarization direction, and detector position can improve the fluorescence collection rate by more than one order of magnitude comparing with that of inefficient geometry. With the fixed 423 nm fluorescence, the improved 657 nm optical frequency standard signal intensity is presented. And the potential application of the Hanle detection geometry designed for facilitating the fluorescence collection for optical lattice clock with a limited solid angle of the fluorescence collection has been discussed. This Hanle detection configuration is also effective for ion detection in ion optical clock and quantum information experiments. Besides, a cylinder fluorescence collection structure is designed to increase the solid angle of the fluorescence collection in Ca atomic beam optical frequency standard.