Researcher profile

Xianlin Song

Xianlin Song contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
9works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2021arXiv

Interaction between optical pulse and tumor using finite element analysis

Photoacoustic imaging is an emerging technology based on the photoacoustic effect that has developed rapidly in recent years. It combines the high contrast of optical imaging and the high penetration and high resolution of acoustic imaging. As a non-destructive biological tissue imaging technology, photoacoustic imaging has important application value in the field of biomedicine. With its high efficiency bi-oimaging capabilities and excellent biosafety performance, it has been favored by researchers. The visualization of photoacoustic imaging has great research signifi-cance in the early diagnosis of some diseases, especially tumors. In photoacoustic imaging, light transmission and thermal effects are important processes. This article is based on COMSOL software and uses finite element analysis to construct a physi-cal model for simulation. Through laser pulses into the stomach tissue containing tumor, the physical process of light transmission and biological heat transfer was studied, and a photothermal model composed of two physical fields was built, and finally a series of visualization graphics were obtained. This work has certain theo-retical guiding significance for further promoting the application of photoacoustic imaging in the field of biomedicine.

preprint2021arXiv

Research on the photoacoustic spectrum analysis using k-Wave

Photoacoustic imaging is a new non-destructive medical imaging technology based on photoacoustic effect. It can reflect the difference of light absorption energy by detecting photoacoustic signal. At present, the analysis methods of photoacoustic signals in biological tissues can be divided into two categories, namely, time-domain analysis of signals and frequency-domain analysis of signals. In time domain analysis, the envelope of the received photoacoustic signal is usually used to reconstruct the image. However, due to the influence of various external factors, the time domain signal cannot accurately reflect the characteristics of the absorber itself. Here, photoacoustic spectrum analysis was performed by using k-Wave to obtains the relationship between the structure, size, density of the absorber and the photoacoustic spectrum. Firstly, the relationship between the size of absorber and the photoacoustic spectrum is studied, and the slope and intercept are used to analyze the spectrum. Conversely, the relationship was used to predict the size of the absorber Finally, we used this relationship to predict the size of blood vessels.

preprint2020arXiv

Axial cosinoidal structured illumination using phase modulation

We propose a novel method for generating axial cosine structured light by using phase-only spatial light modulator. We implemented axial cosine structured light using holographic technique. The computer generates double concentric annular slits with different radius, a prism phase is applied on the slits to tilts the beam that incidents on the slits away from the optical axis. Different annular beam produce Bessel beams with different axial wave vectors, axial cosine structured light can be obtained from the interference between two Bessel beams. The period and phase of axial cosine structured light can be adjusted by adjusting the radius and the initial phase difference of the double concentric annular beams. We theoretically and experimentally verify that the method can effectively generate axial cosine structured light.

preprint2020arXiv

Computed extended depth of field optical-resolution photoacoustic microscope

Photoacoustic microscopy with large depth of focus is significant to the biomedical research. The conventional optical-resolution photoacoustic microscope (OR-PAM) suffers from limited depth of field (DoF) since the employed focused Gaussian beam only has a narrow depth range in focus, little details in depth direction can be revealed. Here, we developed a computed extended depth of field method for photoacoustic microscope by using wavelet transform image fusion rules. Wavelet transform is performed on the max amplitude projection (MAP) images acquired at different axial positions by OR-PAM to separate the low and high frequencies, respectively. The fused low frequency coefficients is taking the average of the low-frequency coefficients of the low-frequency part of the images. And maximum selection rule is used in high frequency coefficients. Wavelet coefficient of the MAP images are compared and select the maximum value coefficient is taken as fused high-frequency coefficients. And finally the wavelet inverse transform is performed to achieve large DoF. Simulation was performed to demonstrate that this method can extend the depth of field of PAM two times without the sacrifice of lateral resolution. And the in vivo imaging of the mouse cerebral vasculature with intact skull further demonstrates the feasibility of our method.

preprint2020arXiv

High-speed varifocal optical-resolution photoacoustic microscope to achieve large depth of field based on a tunable acoustic gradient lens

We developed an optical-resolution photoacoustic microscope (OR-PAM) capable of changing focal plane with high-speed by using a tunable acoustic gradient (TAG) lens. In our system, a TAG lens is designed to continuously changing the focal plane of OR-PAM by modulating its refractive power with fast-changing ultrasonic standing wave. The raster-scanning of the microscope and laser pulses are synchronized to the same phase of the driving signal of TAG lens. By selecting the synchronized phase, arbitrary focal plane can be chosen in a range of about 1 millimeter in 1.4 microseconds in our system. A phantom composed by tungsten wires is used to verified the varifocal capability of the system. In-vivo study was carried out, to further demonstrate the large depth-of-field (DoF) achieved by our method without any moving part.

preprint2020arXiv

Multi-pulse Photoacoustic Microscopy Based on k-space Pseudospectral Method: Simulation Study

Photoacoustic imaging has emerged in the past decades. Compared with the traditional medical imaging mode, it has better imaging performance and has great development potential in the field of biological imaging. In traditional photoacoustic microscopy, a single laser pulse is generally used to irradiate the sample to produce photoacoustic signal. And signal-to-noise ratio (SNR) is a very important indicator for photoacoustic imaging. In order to obtain the image with high SNR, multiple acquisition or increasing laser pulse energy is usually adopted. The former will lead to slower imaging speed, and the latter will lead to photobleaching or phototoxicity. Here, we proposes multi-pulse photoacoustic microscopy, the photoacoustic signals were stimulated sequentially using multiple laser pulses in each A line data acquisition. In order to verify the feasibility of this method, a multi-pulse photoacoustic imaging simulation platform is established using k-Wave toolbox. The performance of multi-pulse photoacoustic imaging is verified through the three scanning modes of photoacoustic microscopy A-scan, B -scan, and C-scan. The results indicate that the SNR is proportion to the number of laser pulses used, high SNR can be achieved by low-energy laser pulse. This work will help to expand the application of photoacoustic imaging.

preprint2020arXiv

Parallel multifocus optical-resolution photoacoustic microscopy based on tunable acoustic gradient lens and fiber delay network

We developed a multifocus optical-resolution photoacoustic microscope (MPAM) with extended depth of field (DoF) by using a tunable acoustic gradient (TAG) lens and a pulse delay method. TAG lens is designed to control the divergence angle of the laser beam. Three fibers with different length are used to output three laser pulses with different delay time. By controlling the fire time of the laser pulses, we can get three focal spot through TAG lens in our system in one A-line data acquisition. The DoF of MPAM measured using a vertically tilted carbon fiber is about 775 micrometers. The lateral resolution is estimated to be 2.8 micrometers. A phantom consists of tungsten wires and a zebrafish is used to verify the large depth-of-field of our system.

preprint2020arXiv

Photoacoustic microscopical simulation platform for large volumetric imaging using Bessel beam

We developed a Bessel-beam photoacoustic microscopical simulation platform by using the k-Wave: MATLAB toolbox. The simulation platform uses the ring slit method to generate Bessel beam. By controlling the inner and outer radius of the ring slit, the depth-of-field (DoF) of Bessel beam can be controlled. And the large volumetric image is obtained by point scanning. The simulation experiments on blood vessels was carried out to demonstrate the feasibility of the simulation plat-form. This simulation work can be used as an auxiliary tool for the research of Bessel-beam photoacoustic microscopy.

preprint2020arXiv

Synthetic multi-focus optical-resolution photoacoustic microscope for large volumetric imaging

Photoacoustic microscopy is becoming an important tool for the biomedical research. It has been widely used in biological researches, such as structural imaging of vasculature, brain structural and functional imaging, and tumor detection. The conventional optical-resolution photoacoustic microscopy (OR- PAM) employs focused gaussian beam to achieve high lateral resolution by a microscope objective with high numerical apertures. Since the focused gaussian beam only has narrow depth range in focus, little detail in depth direction can be revealed. Here, we developed a synthetic multi-focus optical-resolution photoacoustic microscope using multi-scale weighted gradient-based fusion. Based on the saliency of the image structure, a gradient-based multi-focus image fusion method is used, and a multi-scale method is used to determine the gradient weights. We pay special attention to a dual-scale scheme, which effectively solves the fusion problem caused by anisotropic blur and registration error. First, the structure-based large-scale focus measurement method is used to reduce the effect of anisotropic blur and registration error on the detection of the focus area, and then the gradient weights near the edge wave are used by applying the small-scale focus measure. Simulation was performed to test the performance of our method, different focused images were used to verify the feasibility of the method. Performance of our method was analyzed by calculating Entropy, Mean Square Error (MSE) and Edge strength. The result of simulation shown that this method can extend the depth of field of PAM two times without the sacrifice of lateral resolution. And the in vivo imaging of the zebra fish further demonstrates the feasibility of our method.