Source author record

Xiang Xiao

Xiang Xiao appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

16works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

16 published item(s)

preprint2026arXiv

GPS-Synchronized Monitoring of Core-collapse Supernova Bursts with PandaX-4T via Coherent Elastic Neutrino Nuclear Scattering

The landmark detection of neutrinos from SN1987A marked the dawn of neutrino astrophysics. The neutrino burst provided essential insights into fundamental properties of neutrinos, and served as key probes of stellar evolution and supernova dynamics. The recent advancement in coherent elastic neutrino-nucleus scattering enables the detection of core-collapse supernova burst neutrinos using tonne-scale liquid xenon detectors originally designed for dark matter direct detection. Leveraging this capability, we developed and deployed an online supernova monitoring system for the PandaX-4T experiment. This system features a GPS module with millisecond-level timing precision, a low false-alarm rate, and high sensitivity to galactic core-collapse supernova explosion events. The methodology is robust, directly scalable, and planned for implementation in the next-generation PandaX-20T experiment.

preprint2023arXiv

A First Search for Solar $^8$B Neutrino in the PandaX-4T Experiment using Neutrino-Nucleus Coherent Scattering

A search for interactions from solar $^8$B neutrinos elastically scattering off xenon nuclei using PandaX-4T commissioning data is reported. The energy threshold of this search is further lowered compared with the previous search for dark matter, with various techniques utilized to suppress the background that emerges from data with the lowered threshold. A blind analysis is performed on the data with an effective exposure of 0.48 tonne$\cdot$year, and no significant excess of events is observed. Among results obtained using the neutrino-nucleus coherent scattering, our results give the best constraint on the solar $^8$B neutrino flux. We further provide a more stringent limit on the cross section between dark matter and nucleon in the mass range from 3 to 9 GeV/c$^2$.

preprint2022arXiv

A Search for the Cosmic Ray Boosted Sub-GeV Dark Matter at the PandaX-II Experiment

We report a novel search for the cosmic ray boosted dark matter using the 100~tonne$\cdot$day full data set of the PandaX-II detector located at the China Jinping Underground Laboratory. With the extra energy gained from the cosmic rays, sub-GeV dark matter particles can produce visible recoil signals in the detector. The diurnal modulations in rate and energy spectrum are utilized to further enhance the signal sensitivity. Our result excludes the dark matter-nucleon elastic scattering cross section between 10$^{-31}$cm$^{2}$ and 10$^{-28}$cm$^{2}$ for a dark matter masses from 0.1 MeV/$c^2$ to 0.1 GeV/$c^2$, with a large parameter space previously unexplored by experimental collaborations.

preprint2022arXiv

A search for two-component Majorana dark matter in a simplified model using the full exposure data of PandaX-II experiment

In the two-component Majorana dark matter model, one dark matter particle can scatter off the target nuclei, and turn into a slightly heavier component. In the framework of a simplified model with a vector boson mediator, both the tree-level and loop-level processes contribute to the signal in direct detection experiment. In this paper, we report the search results for such dark matter from PandaX-II experiment, using total data of the full 100.7 tonne$\cdot$day exposure. No significant excess is observed, so strong constraints on the combined parameter space of mediator mass and dark matter mass are derived. With the complementary search results from collider experiments, a large range of parameter space can be excluded.

preprint2022arXiv

Low Radioactive Material Screening and Background Control for the PandaX-4T Experiment

PandaX-4T is a ton-scale dark matter direct detection experiment using a dual-phase TPC technique at the China Jinping Underground Laboratory. Various ultra-low background technologies have been developed and applied to material screening for PandaX-4T, including HPGe gamma spectroscopy, ICP-MS, NAA, radon emanation measurement system, krypton assay station, and alpha detection system. Low background materials were selected to assemble the detector. Surface treatment procedures were investigated to further suppress radioactive background. Combining measured results and Monte Carlo simulation, the total material background rates of PandaX-4T in the energy region of 1-25 keV$\rm{}_{ee}$ are estimated to be (9.9 $\pm$ 1.9) $\times \ 10^{-3}$ mDRU for electron recoil and (2.8 $\pm$ 0.6) $\times \ 10^{-4}$ mDRU for nuclear recoil. In addition, $^{nat}$Kr in the detector is estimated to be <8 ppt.

preprint2022arXiv

Mass Testing and Characterization of 20-inch PMTs for JUNO

Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least 3 % at 1 MeV, for which its instruments need to meet a certain quality and thus have to be fully characterized. More than 20,000 20-inch PMTs have been received and assessed by JUNO after a detailed testing program which began in 2017 and elapsed for about four years. Based on this mass characterization and a set of specific requirements, a good quality of all accepted PMTs could be ascertained. This paper presents the performed testing procedure with the designed testing systems as well as the statistical characteristics of all 20-inch PMTs intended to be used in the JUNO experiment, covering more than fifteen performance parameters including the photocathode uniformity. This constitutes the largest sample of 20-inch PMTs ever produced and studied in detail to date, i.e. 15,000 of the newly developed 20-inch MCP-PMTs from Northern Night Vision Technology Co. (NNVT) and 5,000 of dynode PMTs from Hamamatsu Photonics K. K.(HPK).

preprint2022arXiv

Neutron-induced nuclear recoil background in the PandaX-4T experiment

Neutron-induced nuclear recoil background is critical to the dark matter searches in the PandaX-4T liquid xenon experiment. This paper studies the feature of neutron background in liquid xenon and evaluates their contribution in the single scattering nuclear recoil events through three methods. The first method is fully Monte Carlo simulation based. The last two are data-driven methods that also use the multiple scattering signals and high energy signals in the data, respectively. In the PandaX-4T commissioning data with an exposure of 0.63 tonne-year, all these methods give a consistent result that there are $1.15\pm0.57$ neutron-induced background in dark matter signal region within an approximated nuclear recoil energy window between 5 and 100 keV.

preprint2021arXiv

Dark Matter Search Results from the PandaX-4T Commissioning Run

We report the first dark matter search results using the commissioning data from PandaX-4T. Using a time projection chamber with 3.7-tonne of liquid xenon target and an exposure of 0.63 tonne$\cdot$year, 1058 candidate events are identified within an approximate nuclear recoil energy window between 5 and 100 keV. No significant excess over background is observed. Our data set a stringent limit to the dark matter-nucleon spin-independent interactions, with a lowest excluded cross section (90% C.L.) of $3.8\times10^{-47} $cm$^2$ at a dark matter mass of 30 GeV/$c^2$.

preprint2021arXiv

Light yield and field dependence measurement in PandaX-II dual-phase xenon detector

The dual-phase xenon time projection chamber (TPC) is one of the most sensitive detector technology for dark matter direct search, where the energy deposition of incoming particle can be converted into photons and electrons through xenon excitation and ionization. The detector response to signal energy deposition varies significantly with the electric field in liquid xenon. We study the detector's light yield and its dependence on the electric field in the PandaX-II dual-phase detector containing 580~kg liquid xenon in the sensitive volume. From our measurements, the light yield at electric fields from 0~V/cm to 317~V/cm is obtained for energy depositions up to 236~keV.

preprint2021arXiv

Manually Tunable Ventilated Metamaterial Absorbers

For most acoustic metamaterials, once they have been fabricated, their operating frequencies and functions cannot be adjusted, which is an intrinsic barrier for development of realistic applications. The study to overcome this limit has become a significant issue in acoustic metamaterial engineering. Although with the advance of metamaterials in the past two decades, a series of methods such as electric or magnetic control have been proposed, most of them can only work in the condition of no fluid passage. Some metamaterials with large transmission losses have been proposed, but the sounds are essentially reflected rather than absorbed. Here, to overcome this intrinsic difficulty, we propose a ventilated sound absorber that can be manually tuned in a large range after being manufactured. During the tuning which is achieved through an intricately designed slider, high-performance absorption and ventilation are both ensured. The tunable ventilated sound absorber is demonstrated experimentally and the effective model of coupled lossy oscillators can be employed to understand its mechanism. The manually tunable ventilated metamaterial has the potential application values in various complicated pipe systems that require frequency adjustment and it also establishes the foundation for future development of active tunable ventilated acoustic metamaterials.

preprint2016arXiv

Dark Matter Results from First 98.7-day Data of PandaX-II Experiment

We report the WIMP dark matter search results using the first physics-run data of the PandaX-II 500 kg liquid xenon dual-phase time-projection chamber, operating at the China JinPing Underground Laboratory. No dark matter candidate is identified above background. In combination with the data set during the commissioning run, with a total exposure of 3.3$\times10^4$ kg-day,the most stringent limit to the spin-independent interaction between the ordinary and WIMP dark matter is set for a range of dark matter mass between 3.5 and 1000 GeV/c$^2$. The best upper limit on the scattering cross section is found $2.5\times 10^{-46}$ cm$^2$ for the WIMP mass 40 GeV/c$^2$ at 90% confidence level.

preprint2016arXiv

Dark Matter Search Results from the Commissioning Run of PandaX-II

We present the results of a search for WIMPs from the commissioning run of the PandaX-II experiment located at the China Jinping underground Laboratory. A WIMP search data set with an exposure of 306$\times$19.1 kg-day was taken, while its dominant $^{85}$Kr background was used as the electron recoil calibration. No WIMP candidates are identified, and a 90\% upper limit is set on the spin-independent elastic WIMP-nucleon cross section with a lowest excluded cross section of 2.97$\times$10$^{-45}$~cm$^2$ at a WIMP mass of 44.7~GeV/c$^2$.

preprint2015arXiv

Low-mass dark matter search results from full exposure of PandaX-I experiment

We report the results of a weakly-interacting massive particle (WIMP) dark matter search using the full 80.1\;live-day exposure of the first stage of the PandaX experiment (PandaX-I) located in the China Jin-Ping Underground Laboratory. The PandaX-I detector has been optimized for detecting low-mass WIMPs, achieving a photon detection efficiency of 9.6\%. With a fiducial liquid xenon target mass of 54.0\,kg, no significant excess event were found above the expected background. A profile likelihood analysis confirms our earlier finding that the PandaX-I data disfavor all positive low-mass WIMP signals reported in the literature under standard assumptions. A stringent bound on the low mass WIMP is set at WIMP mass below 10\,GeV/c$^2$, demonstrating that liquid xenon detectors can be competitive for low-mass WIMP searches.

preprint2015arXiv

Scintillation and Ionization Responses of Liquid Xenon to Low Energy Electronic and Nuclear Recoils at Drift Fields from 236 V/cm to 3.93 kV/cm

We present new measurements of the scintillation and ionization yields in liquid xenon for low energy electronic (about 3--7 keV$_{ee}$) and nuclear recoils (about 8--20 keV$_{nr}$) at different drift fields from 236 V/cm to 3.93 kV/cm, using a three-dimensional sensitive liquid xenon time projection chamber with high energy and position resolutions. Our measurement of signal responses to nuclear recoils agrees with predictions from the NEST model. However, our measured ionization (scintillation) yields for electronic recoils are consistently higher (lower) than those from the NEST model by about 5 e$^-$/keV$_{ee}$ (ph/keV$_{ee}$) at all scanned drift fields. New recombination parameters based on the Thomas-Imel box model are derived from our data. Given the lack of precise measurement of scintillation and ionization yields for low energy electronic recoils in liquid xenon previously, our new measurement provides so far the best available data covering low energy region at different drift fields for liquid xenon detectors relevant to dark matter searches.

preprint2014arXiv

First dark matter search results from the PandaX-I experiment

We report on the first dark-matter (DM) search results from PandaX-I, a low threshold dual-phase xenon experiment operating at the China Jinping Underground Laboratory. In the 37-kg liquid xenon target with 17.4 live-days of exposure, no DM particle candidate event was found. This result sets a stringent limit for low-mass DM particles and disfavors the interpretation of previously-reported positive experimental results. The minimum upper limit, $3.7\times10^{-44}$\,cm$^2$, for the spin-independent isoscalar DM-particle-nucleon scattering cross section is obtained at a DM-particle mass of 49\,GeV/c$^2$ at 90\% confidence level.

preprint2013arXiv

High Resolution Gamma Ray Detection in a Dual Phase Xenon Time Projection Chamber

Dual phase Xenon Time Projection Chambers (XeTPCs) are being used by several experiments as a promising technique for direct detection of dark matter. We report on the design and performance of a small 3-D sensitive dual phase XeTPC. The position resolution is 2 mm in the center of detector, limited by the hole size of the mesh at the proportional scintillation region. An energy resolution of 1.6%(σ /E) for 662 keV gamma rays is achieved by combining the ionization and scintillation signals at a drift field of 0.5 kV/cm. This represents the best energy resolution achieved among liquid xenon detectors. The energy resolution is only slightly dependent on drift field. Better than 2% energy resolution (σ /E) for 662 keV gamma rays can be achieved for drift fields between 100 V/cm and 2 kV/cm. With high position and energy resolutions, a dual phase XeTPC has also potential applications in surveys for neutrinoless double-beta decay and in gamma ray imaging.