Source author record

William Cunningham

William Cunningham appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2021arXiv

A MEMS gravimeter with multi-axis gravitational sensitivity

A single-axis Microelectromechanical system gravimeter has recently been developed at the University of Glasgow. The sensitivity and stability of this device was demonstrated by measuring the Earth tides. The success of this device was enabled in part by its extremely low resonant frequency. This low frequency was achieved with a geometric anti-spring design, fabricated using well-established photolithography and dry etch techniques. Analytical models can be used to calculate the results of these non-linear oscillating systems, but the power of finite element analysis has not been fully utilised to explore the parameter space before now. In this article, the results of previous analytical solutions are replicated using finite element models, before applying the same techniques to optimise the design of the gravimeter. These computer models provide the ability to investigate the effect of the fabrication material of the device: anisotropic <100> crystalline silicon. This is a parameter that is difficult to investigate analytically, but finite element modelling is demonstrated here to provide accurate predictions of real gravimeter behaviour by taking anisotropy into account. The finite element models are then used to demonstrate the design of a three-axis gravimeter enabling the gravity tensor to be measured - a significantly more powerful surveying tool than the original single-axis device.

preprint2015arXiv

Eguchi-Kawai reduction with one flavor of adjoint Moebius fermion

We study the single site lattice gauge theory of SU(N) coupled to one Dirac flavor of fermion in the adjoint representation. We utilize Möbius fermions for this study, and accelerate the calculation with graphics processing units (GPUs). Our Monte Carlo simulations indicate that for sufficiently large inverse 't Hooft coupling b = 1/g^2 N, and for N \leq 10 the distribution of traced Polyakov loops has "fingers" that extend from the origin. However, in the massless case the distribution of eigenvalues of the untraced Polyakov loop becomes uniform at large N, indicating preservation of center symmetry in the thermodynamic limit. By contrast, for a large mass and large b, the distribution is highly nonuniform in the same limit, indicating spontaneous center symmetry breaking. These conclusions are confirmed by comparing to the quenched case, as well as by examining another observable based on the average value of the modulus of the traced Polyakov loop. The result of this investigation is that with massless adjoint fermions center symmetry is stabilized and the Eguchi-Kawai reduction should be successful; this is in agreement with most other studies.