Source author record

Wenxi Peng

Wenxi Peng appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2026arXiv

Brightest GRB flare observed in GRB 221009A: bridge the last gap between flare and prompt emission in GRB

Flares are usually observed during the afterglow phase of Gamma-Ray Bursts (GRBs) in soft X-ray, optical and radio bands, but rarely in gamma-ray band. Despite the extraordinary brightness, GECAM-C has accurately measured both the bright prompt emission and flare emission of GRB 221009A without instrumental effects, offering a good opportunity to study the relation between them. In this work, we present a comprehensive analysis of flare emission of GRB 221009A, which is composed of a series of flares. Among them, we identify an exceptionally bright flare with a record-breaking isotropic energy $E_{\rm iso} = 1.82 \times 10^{53}$ erg of GRB flares. It exhibits the highest peak energy ever detected in GRB flares, $E_{\rm peak} \sim 300$ keV, making it a genuine gamma-ray flare. It also shows rapid rise and decay timescales, significantly shorter than those of typical X-ray flares observed in soft X-ray or optical band, but comparable to those observed in prompt emissions. Despite these exceptional properties, the flare shares several common properties with typical GRB flares. We note that this is the first observation of a GRB flare in the keV-MeV band with sufficiently high temporal resolution and high statistics, which bridges the last gap between prompt emission and flare.

preprint2022arXiv

CATCH: Chasing All Transients Constellation Hunters Space Mission

In time-domain astronomy, a substantial number of transients will be discovered by multi-wavelength and multi-messenger observatories, posing a great challenge for follow-up capabilities. We have thus proposed an intelligent X-ray constellation, the Chasing All Transients Constellation Hunters (CATCH) space mission. Consisting of 126 micro-satellites in three types, CATCH will have the capability to perform follow-up observations for a large number of different types of transients simultaneously. Each satellite in the constellation will carry lightweight X-ray optics and use a deployable mast to increase the focal length. The combination of different optics and detector systems enables different types of satellites to have multiform observation capabilities, including timing, spectroscopy, imaging, and polarization. Controlled by the intelligent system, different satellites can cooperate to perform uninterrupted monitoring, all-sky follow-up observations, and scanning observations with a flexible field of view (FOV) and multi-dimensional observations. Therefore, CATCH will be a powerful mission to study the dynamic universe. Here, we present the current design of the spacecraft, optics, detector system, constellation configuration and observing modes, as well as the development plan.

preprint2021arXiv

Gain stabilization and consistency correction approach for multiple SiPM-based gamma-ray detectors on GECAM

Each satellite of the Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM, mission) consists of 25 SiPM based gamma-ray detectors (GRDs). Although SiPM based GRD has merits of compact size and low bias-voltage, the drift of the SiPM gain with temperature is a severe problem for GRD performance. An adaptive voltage supply source was designed to automatically adjust the SiPM bias voltage to compensate the temperature effects and keep the gain stable. This approach has been proved to be effective during both the on-ground and in-flight tests. The in-flight measured variation of the SiPM gain is within 2%. To reduce the gain non-uniformity of GRDs, an iterative bias voltage adjustment approach is proposed and implemented. The gain non-uniformity is reduced from 17% to 0.6%. In this paper, the gain stabilization and consistency correction approach are presented and discussed in detail.

preprint2015arXiv

Ground-based verification and data processing of Yutu rover Active Particle-induced X-ray Spectrometer

The Active Particle-induced X-ray Spectrometer (APXS) is one of the payloads on board the Yutu rover of Chang'E-3 mission. In order to assess the instrumental performance of APXS, a ground verification test was done for two unknown samples (basaltic rock, mixed powder sample). In this paper, the details of the experiment configurations and data analysis method are presented. The results show that the elemental abundance of major elements can be well determined by the APXS with relative deviations < 15 wt. % (detection distance = 30 mm, acquisition time = 30 min). The derived detection limit of each major element is inversely proportional to acquisition time and directly proportional to detection distance, suggesting that the appropriate distance should be < 50mm.

preprint2014arXiv

Physical Design and Monte Carlo Simulations of a Space Radiation Detector onboard the SJ-10 satellite

A radiation gene box (RGB) onboard the SJ-10 satellite is a device carrying mice and drosophila cells to determine the biological effects of space radiation environment. The shielded fluxes of different radioactive sources were calculated and the linear energy transfers of gamma-rays, electrons, protons and alpha-particles in tissue were acquired using A-150 tissue-equivalent plastic. Then, a conceptual model of a space radiation instrument employing three semiconductor sub-detectors for deriving the charged and uncharged radiation environment of the RGB was designed. The energy depositions in the three sub-detectors were classified into fifteen channels (bins) in an algorithm derived from the Monte Carlo method. The physical feasibility of the conceptual instrument was also verified by Monte Carlo simulations.