Source author record

Wenli Liu

Wenli Liu appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2016arXiv

Modules and Structures of Planar Upper Triangular Rook Monoids

In this paper, we discuss modules and structures of the planar upper triangular rook monoid B_n. We first show that the order of B_n is a Catalan number, then we investigate the properties of a module V over B_n generated by a set of elements v_S indexed by the power set of {1, ..., n}. We find that every nonzero submodule of V is cyclic and completely decomposable; we give a necessary and sufficient condition for a submodule of V to be indecomposable. We show that every irreducible submodule of V is 1-dimensional. Furthermore, we give a formula for calculating the dimension of every submodule of V. In particular, we provide a recursive formula for calculating the dimension of the cyclic module generated by v_S, and show that some dimensions are Catalan numbers, giving rise to new combinatorial identities.

preprint2013arXiv

Automatic Calibration Method of Voxel Size for Cone-beam 3D-CT Scanning System

For cone-beam three-dimensional computed tomography (3D-CT) scanning system, voxel size is an important indicator to guarantee the accuracy of data analysis and feature measurement based on 3D-CT images. Meanwhile, the voxel size changes with the movement of the rotary table along X-ray direction. In order to realize the automatic calibration of the voxel size, a new easily-implemented method is proposed. According to this method, several projections of a spherical phantom are captured at different imaging positions and the corresponding voxel size values are calculated by non-linear least square fitting. Through these interpolation values, a linear equation is obtained, which reflects the relationship between the rotary table displacement distance from its nominal zero position and the voxel size. Finally, the linear equation is imported into the calibration module of the 3D-CT scanning system, and when the rotary table is moving along X-ray direction, the accurate value of the voxel size is dynamically exported. The experimental results prove that this method meets the requirements of the actual CT scanning system, and has virtues of easy implementation and high accuracy