Researcher profile

Wei Long

Wei Long contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - Emerging
11works
0followers
7topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2026arXiv

From Local Windows to Adaptive Candidates via Individualized Exploratory: Rethinking Attention for Image Super-Resolution

Single Image Super-Resolution (SISR) is a fundamental computer vision task that aims to reconstruct a high-resolution (HR) image from a low-resolution (LR) input. Transformer-based methods have achieved remarkable performance by modeling long-range dependencies in degraded images. However, their feature-intensive attention computation incurs high computational cost. To improve efficiency, most existing approaches partition images into fixed groups and restrict attention within each group. Such group-wise attention overlooks the inherent asymmetry in token similarities, thereby failing to enable flexible and token-adaptive attention computation. To address this limitation, we propose the Individualized Exploratory Transformer (IET), which introduces a novel Individualized Exploratory Attention (IEA) mechanism that allows each token to adaptively select its own content-aware and independent attention candidates. This token-adaptive and asymmetric design enables more precise information aggregation while maintaining computational efficiency. Extensive experiments on standard SR benchmarks demonstrate that IET achieves state-of-the-art performance under comparable computational complexity.

preprint2020arXiv

Multi-Peak solutions to Chern-Simons-Schrödinger systems with non-radial potential

In this paper, we consider the existence of static solutions to the nonlinear Chern-Simons-Schrödinger system \begin{equation}\label{eqabstr} \left\{\begin{array}{ll} -ihD_0Ψ-h^2(D_1D_1+D_2D_2)Ψ+VΨ=|Ψ|^{p-2}Ψ,\\ \partial_0A_1-\partial_1A_0=-\frac 12ih[\overlineΨD_2Ψ-Ψ\overline{D_2Ψ}],\\ \partial_0A_2-\partial_2A_0=\frac 12ih[\overlineΨD_1Ψ-Ψ\overline{D_1Ψ}],\\ \partial_1A_2-\partial_2A_1=-\frac12|Ψ|^2,\\ \end{array} \right. \end{equation} where $p>2$ and non-radial potential $V(x)$ satisfies some certain conditions. We show that for every positive integer $k$, there exists $h_0>0$ such that for $0<h<h_0$, problem \eqref{eqabstr} has a nontrivial static solution $(Ψ_h, A_0^h, A_1^h,A_2^h)$. Moreover, $Ψ_h$ is a positive non-radial function with $k$ positive peaks, which approach to the local maximum point of $V(x)$ as $h\to 0^+$.

preprint2016arXiv

Highly Catalytic Nanodots with Renal Clearance for Radiation Protection

Ionizing radiation (gamma and x-ray) is widely used in industry and medicine, but it can also pose a significant hazardous effect on health and induce cancer, physical deformity and even death, due to DNA damages and invasion of free radicals. There is therefore an urgent unmet demand in designing highly efficient radioprotectants with synergetic integration of effective renal clearance and low toxicity. In this study, we designed ultrasmall (sub-5 nm) highly catalytically active and cysteine-protected MoS2 dots as radioprotectants and investigated their application in protection against ionizing radiation. In vivo preclinical studies showed that the surviving fraction of MoS2-treated mice can appreciably increase to up to 79 % when they were exposed to high-energy ionizing radiation. Furthermore, MoS2 dots can contribute in cleaning up the accumulated free radicals within the body, repairing DNA damages and recovering all vital chemical and biochemical indicators, suggesting their unique role as free radical scavengers. MoS2 dots showed rapid and efficient urinary excretion with more than 80 % injected dose (I.D.) eliminated from the body after 24 hours due to their ultrasmall hydrodynamic size and did not cause any noticeable toxic responses up to 30 days.

preprint2015arXiv

Distributed User Scheduling for MIMO-Y Channel

In this paper, distributed user scheduling schemes are proposed for the multi-user MIMO-Y channel, where three $N_{T}$-antenna users ($N_{T}=2N,\,3N$) are selected from three clusters to exchange information via an $N_{R}$-antenna amplify-and-forward (AF) relay ($N_{R}=3N$), and $N\geq1$ represents the number of data stream(s) of each unicast transmission within the MIMO-Y channel. The proposed schemes effectively harvest multi-user diversity (MuD) without the need of global channel state information (CSI) or centralized computations. In particular, a novel reference signal space (RSS) is proposed to enable the distributed scheduling for both cluster-wise (CS) and group-wise (GS) patterns. The minimum user-antenna (Min-UA) transmission with $N_{T}=2N$ is first considered. Next, we consider an equal number of relay and user antenna (ER-UA) transmission with ${N_{T}=3N}$, with the aim of reducing CSI overhead as compared to Min-UA. For ER-UA transmission, the achievable MuD orders of the proposed distributed scheduling schemes are analytically derived, which proves the superiority and optimality of the proposed RSS-based distributed scheduling. These results reveal some fundamental behaviors of MuD and the performance-complexity tradeoff of user scheduling schemes in the MIMO-Y channel.

preprint2015arXiv

Investigation of the Time Performance of a LYSO Array for TOF-PET

Positron Emission Tomography (PET) using time-of-flight information, which can greatly improve the quality of the reconstructed image, has recently become an exciting topic. In this work, 3.2mm*3.2mm*25mm finger-like LYSO crystals were used to make a 5*5 array, coupled to the Hamamatsu H8500 photomultiplier tube (PMT) as a detector. A fast leading-edge discriminator was designed for the LYSO-H8500 detector. Average coincidence time resolution FWHM of 330 ps was obtained for the LYSO detector with a reference BaF2 detector, whose time resolution for 511 keV γ-rays was FWHM 150 ps. Time resolution FWHM of 294 ps was calculated for the LYSO detector, and coincidence time resolution of FHWM 415 ps can be expected for two identical LYSO detectors.

preprint2015arXiv

Positive or sign-changing solutions for a critical semilinear nonlocal equation

We consider the following critical semilinear nonlocal equation involving the fractional Laplacian $$ (-Δ)^su=K(|x|)|u|^{2^*_s-2}u,\ \ \hbox{in}\ \ \mathbb{R}^N, $$ where $K(|x|)$ is a positive radial function, $N>2+2s$, $0<s<1$, and $2^*_s=\frac{2N}{N-2s}$. Under some asymptotic assumptions on $K(x)$ at an extreme point, we show that this problem has infinitely many non-radial positive or sign-changing solutions.

preprint2014arXiv

A Novel Scheme for Downlink Opportunistic Interference Alignment

In this paper we propose a downlink codebook-based opportunistic interference alignment (OIA) in a three-cell MIMO system. A codebook composed of multiple transmit vector sets is utilized to improve the multiuser selection diversity. The sum rate increases as the size of the codebook grows. In addition, during the user selection, effective channel gain and alignment metric are combined to generate a novel criterion, which improves the system performance, especially at low SNR. Furthermore, a threshold-based feedback approach is introduced to reduce the feedback load in the proposed scheme. Both the analytical results and simulations show that the proposed scheme provides significant improvement in terms of sum rates with no feedback load growth and slight increase of complexity.

preprint2014arXiv

Infinitely many positive solutions for nonlinear fractional Schrödinger equations

We consider the following nonlinear fractional Schrödinger equation $$ (-Δ)^su+u=K(|x|)u^p,\ \ u>0 \ \ \hbox{in}\ \ R^N, $$ where $K(|x|)$ is a positive radial function, $N\ge 2$, $0<s<1$, $1<p<\frac{N+2s}{N-2s}$. Under some asymptotic assumptions on $K(x)$ at infinity, we show that this problem has infinitely many non-radial positive solutions, whose energy can be made arbitrarily large.

preprint2014arXiv

PET image reconstruction with system matrix containing point spread function derived from single photon incidence response

In positron emission tomography (PET) imaging, statistical iterative reconstruction (IR) techniques appear particularly promising since they can provide accurate system model. The system model matrix which describes the relationship between image space and projection space is important to the image quality. It contains some factors such as geometrical component and blurring component. The blurring component is usually described by point spread function (PSF). A PSF matrix derived from the single photon incidence response function is studied. And then an IR method based on the system matrix containing the PSF is developed. More specifically, the gamma photon incidence on a crystal array is simulated by Monte Carlo (MC) simulation, and then the single photon incidence response functions are calculated. Subsequently, the single photon incidence response functions is used to compute the coincidence blurring factor according to the physical process of PET coincidence detection. Through weighting the ordinary system matrix response by the coincidence blurring factors, the IR system matrix containing PSF is finally established. Using this system matrix, the image is reconstructed by ordered subset expectation maximization (OSEM) algorithm. The experimental results show that the proposed system matrix can obviously improve the image radial resolution, contrast and noise property. Furthermore, the simulated single gamma-ray incidence response function only depends on the crystal configuration, so the method could be extended to any PET scanners with the same detector crystal configuration.

preprint2014arXiv

Storage of Gold Nanoclusters in Muscle Leads to their Biphasic in Vivo Clearance

Ultrasmall gold nanoclusters show great potential in biomedical applications. Long term biodistribution, retention, toxicity, and pharmacokinetics profiles are prerequisites in their potential clinical applications. Here we systematically investigated the biodistribution, clearance, and toxicity of one widely used Au NC species glutathione protected Au NCs or GSH Au NCs, over a relatively long period of 90 days in mice. We observed that most of the Au NCs were cleared at 30 days post injection with a major accumulation in liver and kidney. However, it is surprising that an abnormal increase of Au amount in the heart, liver, spleen, lung, and testis was observed at 60 and 90 days, indicating that the injected Au NCs formed a V shaped time dependent distribution profile in various organs. Further investigations revealed that Au NCs were steadily accumulating in the muscle in the first 30 days p.i., and the as stored Au NCs gradually released into blood in 30 to 90 days, which induced a redistribution and reaccumulation of Au NCs in all blood rich organs. Further hematology and biochemistry studies showed that the reaccumulation of Au NCs still caused some liver toxicity at 30 days p.i. The muscle storage and subsequent release may give rise to the potential accumulation and toxicity risk of functional nanomaterials over long periods of time.

preprint2013arXiv

Experimental measurement of radiation dose in a dedicated breast CT system

Radiation dose is an important performance indicator of a dedicated breast CT (DBCT). In this paper, the method of putting thermoluminescent dosimeters (TLD) into a breast shaped PMMA phantom to study the dose distribution in breasts was improved by using smaller TLDs and a new half-ellipsoid PMMA phantom. Then the weighted CT dose index (CTDIw) was introduced to average glandular assessment in DBCT for the first time and two measurement modes were proposed for different sizes of breasts. The dose deviations caused by using cylindrical phantoms were simulated using the Monte Carlo method and a set of correction factors were calculated. The results of the confirmatory measurement with a cylindrical phantom (11cm/8cm) show that CTDIw gives a relatively conservative overestimate of the average glandular dose comparing to the results of Monte Carlo simulation and TLDs measurement. But with better practicability and stability, the CTDIw is suitable for dose evaluations in daily clinical practice. Both of the TLDs and CTDIw measurements demonstrate that the radiation dose of our DBCT system is lower than conventional two-view mammography.