Source author record

Wei Gai

Wei Gai appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2016arXiv

In situ Observation of Dark Current Emission in a High Gradient RF Photocathode Gun

Undesirable electron field emission (a.k.a. dark current) in high gradient RF photocathode guns deteriorates the quality of photoemission current and limits the operational gradient. To improve the understanding of dark current emission, a high-resolution (~100 um) dark current imaging experiment has been performed in an L-band photocathode gun operating at ~100 MV/m of surface gradient. Dark current from the cathode has been observed to be dominated by several separated strong emitters. The field enhancement factor, beta, of selected regions on the cathode has been measured. The post scanning electron microscopy (SEM) and white light interferometer (WLI) surface examinations reveal the origins of ~75% strong emitters overlap with the spots where rf breakdown have occurred.

preprint2015arXiv

Beam optical design for high energy electron radiography experiment study based on THU LINAC

A special beam line for high energy electron radiography is designed, including achromat and imaging systems. The requirement of the angle and position correction on the target from imaging system can be approximately realized by fine tuning the quadrupoles used in the achromat. The imaging system is designed by fully considering the limitation from the laboratory and beam diagnostics devices space. Two kinds of imaging system are designed and both show a good performance of imaging by beam trajectory simulation. The details of the beam optical requirement and optimization design are presented here. The beam line is designed and prepared to install in Tsinghua university linear electron accelerator laboratory for further precise electron radiography experiment study.

preprint2014arXiv

Planar Ultrananocrystalline Diamond Field Emitter in Accelerator RF Electron Injector: Performance Metrics

A case performance study of a planar field emission cathode (FEC) based on nitrogen-incorporated ultrananocrystalline diamond, (N)UNCD, was carried out in an RF 1.3 GHz electron gun. The FEC was a 100 nm (N)UNCD film grown on a 20 mm diameter stainless steel disk with a Mo buffer layer. At surface gradients 45-65 MV/m, peak currents of 1-80 mA (equivalent to 0.3-25 mA/cm$^2$) were achieved. Imaging with two YAG screens confirmed emission from the (N)UNCD surface with (1) the beam emittance of 1.5 mm$\times$mrad/mm-rms, and (2) longitudinal FWHM and rms energy spread of 0.7% and 11% at an electron energy of 2 MeV. Current stability was tested over the course of 36$\times$10$^3$ RF pulses (equivalent to 288$\times$10$^6$ GHz oscillations).

preprint2013arXiv

Positron Source Simulations for ILC 1 TeV Upgrade

The generation and capture of polarized positrons at a source with a superconducting helical undulator having 4.3 cm period and 500 GeV electron drive beam have been simulated. The positron polarization has been calculated for the different undulator K values (up to K = 2.5). Without applying a photon collimator, the maximal polarization of positrons is about 25% for 231 meters active magnet length of undulator with K = 0.7. Using an undulator with K = 2.5 and a collimator with an aperture radius of 0.9 mm results in increase of positron polarization to 54%. The energy deposition, temperature rise and stress induced by high intense photon beam in the rotated titanium-alloy target have been estimated. The maximal thermal stress in the target is about 224 MPa for the source with photon collimation to achieve a positron polarization of 54%.

preprint2013arXiv

The International Linear Collider Technical Design Report - Volume 3.I: Accelerator R&D in the Technical Design Phase

The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carried out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to increase significantly our understanding of the fundamental processes that govern the evolution of the Universe.

preprint2013arXiv

The International Linear Collider Technical Design Report - Volume 3.II: Accelerator Baseline Design

The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carried out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to increase significantly our understanding of the fundamental processes that govern the evolution of the Universe.

preprint2011arXiv

A conventional positron source for International Linear Collider

A possible solution to realize a conventional positron source driven by a several-GeV electron beam for the International Linear Collider is proposed. A 300 Hz electron linac is employed to create positrons with stretching pulse length in order to cure target thermal load. ILC requires about 2600 bunches in a train which pulse length is 1 ms. Each pulse of the 300 Hz linac creates about 130 bunches, then 2600 bunches are created in 63 ms. Optimized parameters such as drive beam energy, beam size, and target thickness, are discussed assuming a L-band capture system to maximize the capture efficiency and to mitigate the target thermal load. A slow rotating tungsten disk is employed as positron generation target.