Researcher profile

W. Snoeys

W. Snoeys contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Charge collection properties of TowerJazz 180 nm CMOS Pixel Sensors in dependence of pixel geometries and bias parameters, studied using a dedicated test-vehicle: the Investigator chip

This paper contains a compilation of parameters influencing the charge collection process extracted from a comprehensive study of partially depleted Monolithic Active Pixel Sensors with small (<25 um$^2$) collection electrodes fabricated in the TowerJazz 180 nm CMOS process. These results gave guidance for the optimisation of the diode implemented in ALPIDE, the chip used in the second generation Inner Tracking System of ALICE, and serve as reference for future simulation studies of similar devices. The studied parameters include: reverse substrate bias, epitaxial layer thickness, charge collection electrode size and the spacing of the electrode to surrounding in-pixel electronics. The results from pixels of 28 um pitch confirm that even in partially depleted circuits, charge collection can be fast (<10 ns), and quantify the influence of the parameters onto the signal sharing and amplitudes, highlighting the importance of a correct spacing between wells and of the impact of the reverse substrate bias.

preprint2019arXiv

Mini-MALTA: Radiation hard pixel designs for small-electrode monolithic CMOS sensors for the High Luminosity LHC

Depleted Monolithic Active Pixel Sensor (DMAPS) prototypes developed in the TowerJazz 180 nm CMOS imaging process have been designed in the context of the ATLAS upgrade Phase-II at the HL-LHC. The pixel sensors are characterized by a small collection electrode (3 $μ$m) to minimize capacitance, a small pixel size ($36.4\times 36.4$ $μ$m), and are produced on high resistivity epitaxial p-type silicon. The design targets a radiation hardness of $1\times10^{15}$ 1 MeV n$_{eq}$/cm$^{2}$, compatible with the outermost layer of the ATLAS ITK Pixel detector. This paper presents the results from characterization in particle beam tests of the Mini-MALTA prototype that implements a mask change or an additional implant to address the inefficiencies on the pixel edges. Results show full efficiency after a dose of $1\times10^{15}$ 1 MeV n$_{eq}$/cm$^{2}$.

preprint2018arXiv

Elastic differential cross-section ${\rm d}σ/{\rm d}t$ at $\sqrt{s}=$2.76 TeV and implications on the existence of a colourless 3-gluon bound state

The proton-proton elastic differential cross section ${\rm d}σ/{\rm d}t$ has been measured by the TOTEM experiment at $\sqrt{s}=2.76$ TeV energy with $β^{*}=11$ m beam optics. The Roman Pots were inserted to 13 times the transverse beam size from the beam, which allowed to measure the differential cross-section of elastic scattering in a range of the squared four-momentum transfer ($|t|$) from $0.36$ GeV$^{2}$ to $0.74$ GeV$^{2}$. The differential cross-section can be described with an exponential in the $|t|$-range between $0.36$ GeV$^{2}$ and $0.54$ GeV$^{2}$, followed by a diffractive minimum (dip) at $|t_{\rm dip}| = 0.61 \pm 0.03$ GeV$^{2}$ and a subsequent maximum (bump). The ratio of the ${\rm d}σ/{\rm d}t$ at the bump and at the dip is $1.7\pm 0.2$. When compared to the $\rm p\bar{p}$ measurement of the D0 experiment at $\sqrt s = 1.96$ TeV, a significant difference can be observed. Under the condition that the effects due to the energy difference between TOTEM and D0 can be neglected, the result provides evidence for a colourless 3-gluon bound state exchange in the $t$-channel of the proton-proton elastic scattering.

preprint2018arXiv

Elastic differential cross-section measurement at $\sqrt{s}=13$ TeV by TOTEM

The TOTEM collaboration has measured the elastic proton-proton differential cross section ${\rm d}σ/{\rm d}t$ at $\sqrt{s}=13$ TeV LHC energy using dedicated $β^{*}=90$ m beam optics. The Roman Pot detectors were inserted to 10$σ$ distance from the LHC beam, which allowed the measurement of the range $[0.04$ GeV$^{2}$$; 4 $GeV$^{2}$$]$ in four-momentum transfer squared $|t|$. The efficient data acquisition allowed to collect about 10$^{9}$ elastic events to precisely measure the differential cross-section including the diffractive minimum (dip), the subsequent maximum (bump) and the large-$|t|$ tail. The average nuclear slope has been found to be $B=(20.40 \pm 0.002^{\rm stat} \pm 0.01^{\rm syst})~$GeV$^{-2}$ in the $|t|$-range $0.04~$GeV$^{2}$ to $0.2~$GeV$^{2}$. The dip position is $|t_{\rm dip}|=(0.47 \pm 0.004^{\rm stat} \pm 0.01^{\rm syst})~$GeV$^{2}$. The differential cross section ratio at the bump vs. at the dip $R=1.77\pm0.01^{\rm stat}$ has been measured with high precision. The series of TOTEM elastic pp measurements show that the dip is a permanent feature of the pp differential cross-section at the TeV scale.