Source author record

Vyacheslav Klyukhin

Vyacheslav Klyukhin appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2024arXiv

Calculation of Forces on the High Granularity Calorimeter Stainless Steel Absorber Plates in the Compact Muon Solenoid Magnetic Field

The general-purpose Compact Muon Solenoid (CMS) detector at the Large Hadron Collider (LHC) at CERN includes the hadronic calorimeter to register the energies of the charged and neutral hadrons produced in the proton-proton collisions at the LHC at a centre of mass energy 13.6 TeV. The calorimeter is located inside the superconducting solenoid of 6 m in diameter and 12.5 m in length creating the central magnetic flux density of 3.8 T. For operating optimally in the high pileup and high radiation environment of the High Luminosity LHC, the existing CMS endcap calorimeters will be replaced with a new high granularity calorimeter (HGCal) comprising of an electromagnetic and a hadronic section in each of the two endcaps. The hadronic section of the HGCAL will include 44 stainless steel absorber plates with a relative permeability value well below 1.05. The volume occupied by 22 plates in each endcap is about 21 m$^{3}$. The calculation of the axial electromagnetic forces on the absorber plates is a crucial element in designing the mechanical construction of the device. With a three-dimensional computer model of the CMS magnet, the axial forces on each absorber plate are calculated and the dependence of forces on the central magnetic flux density value is presented. The method of calculation and the obtained results are discussed.

preprint2024arXiv

Calculation of Forces to the High Granularity Calorimeter Stainless Steel Absorbers Misaligned inside the CMS Superconducting Coil

The general-purpose Compact Muon Solenoid (CMS) detector at the Large Hadron Collider (LHC) at CERN includes the hadronic calorimeter to register the energies of the charged and neutral hadrons produced in the proton-proton collisions at the LHC at a centre of mass energy 13.6 TeV. The calorimeter is located inside the superconducting solenoid of 6 m in diameter and 12.5 m in length operating with a direct current of 18.164 kA that creates the central magnetic flux density of 3.81 T. To fit optimally to the high pileup and high radiation environment of the High Luminosity LHC, the existing CMS endcap calorimeter will be replaced with a new high granularity calorimeter (HGCal) comprising the electromagnetic and hadronic sections. The hadronic section in each of two endcaps of the HGCal will include 22 stainless steel absorber plates with a relative permeability value of 1.000588 at to the central magnetic flux density of 3.81 T. The calculation of the electromagnetic forces to the absorber plates due to orthogonal and angular misalignments of the HGCal endcaps with respect to the coil axis is performed with a three-dimensional computer model of the CMS magnet using the method of calculation described earlier.

preprint2024arXiv

Comparison of Two Detector Magnetic Systems for the Future Circular Hadron-Hadron Collider

The conceptual design study of a Future Circular hadron-hadron Collider (FCC-hh) to be con-structed at CERN with a center-of-mass energy of the order of 100 TeV requires superconducting magnetic systems with a central magnetic flux density of an order of 4 T for the experimental detectors. The developed concept of the FCC-hh detector involves the use of an iron-free magnetic system consisting of three superconducting solenoids. A superconducting magnet with a minimal steel yoke is proposed as an alternative to the baseline iron-free design. In this study, both magnetic system options for the FCC-hh detector are modeled with the same electrical parameters using Cobham$'$s program TOSCA. All the main characteristics of both designs are compared and discussed.

preprint2024arXiv

Development of the CMS Magnetic Field Map

This article focuses on pioneering work on the performance of the three-dimensional (3D) magnetic field map in the entire volume of the Compact Muon Solenoid (CMS) detector at the Large Hadron Collider at CERN. In the CMS heterogeneous magnetic system, the magnetic flux is created by a superconducting solenoid coil enclosed in a steel flux-return yoke. To describe the CMS magnetic flux distribution, a system of the primitive 3D volumes containing the values of the magnetic flux density measured inside the superconducting coil inner volume and modelled outside the coil across a special mesh of reference nodes was developed. This system, called the CMS magnetic field map, follows the geometric features of the yoke and allows the interpolation of the magnetic flux density between the nodes to obtain the magnetic field values at any spatial point inside a cylinder of 18 m in diameter and 48 m in length, where all the CMS sub-detectors are located. The geometry of the volumes is described inside one 30° azimuthal sector of the CMS magnet. To obtain the values of the magnetic flux density components across the entire azimuth angle of the CMS detector, rotational symmetry is applied.

preprint2022arXiv

Design and Description of the CMS Magnetic System Model

This review describes the composition of the Compact Muon Solenoid (CMS) detector and the methodology for modelling the heterogeneous CMS magnetic system, starting with the formulation of the magnetostatics problem for modelling the magnetic flux of the CMS superconducting solenoid enclosed in a steel flux-return yoke. The review includes a section on the magnetization curves of various types of steel used in the CMS magnet yoke. The evolution of the magnetic system model over 20 years is presented in the discussion section and is well illustrated by the CMS model layouts and the magnetic flux distribution.

preprint2022arXiv

The CMS Magnetic Field Measuring and Monitoring Systems

This review article describes the performance of the magnetic field measuring and monitoring systems for the Compact Muon Solenoid (CMS) detector. To cross-check the magnetic flux distribution obtained with the CMS magnet model, four systems for measuring the magnetic flux density in the detector volume were used. The magnetic induction inside the 6 m diameter superconducting solenoid was measured and is currently monitored by four nuclear magnetic resonance (NMR) probes installed using special tubes outside the barrel hadron calorimeter. Two more NRM probes were installed at the faces of the tracking system. The field inside the superconducting solenoid was precisely measured in 2006 in a cylindrical volume of 3.448 m in diameter and 7 m in length using 10 three-dimensional (3D) B-sensors based on the Hall effect. These B-sensors were installed on each of the two propeller arms of an automated field-mapping machine. In addition to these measurement systems, a system for monitoring the magnetic field during the CMS detector operation has been developed. Inside the solenoid in the horizontal plane, 4 3D B-sensors were installed at the faces of the tracking detector. Twelve 3D B-sensors were installed on the surfaces of the flux-return yoke nose disks. Seventy 3D B-sensors were installed in the air gaps of the CMS magnet yoke. A specially developed flux loop technique was used for the most complex measurements of the magnetic flux density inside the steel blocks of the CMS magnet yoke. The flux loops are installed in 22 sections of the flux-return yoke blocks. The areas enclosed by these coils varied from 0.3 to 1.59 m$^{2}$ in the blocks of the barrel wheels and from 0.5 to 1.12 m$^{2}$ in the blocks of the yoke endcap disks. The development of these systems and the results of the magnetic flux density measurements across the CMS magnet are presented and discussed in this review article.

preprint2022arXiv

Using the Standard Linear Ramps of the CMS Superconducting Magnet for Measuring the Magnetic Flux Density in the Steel Flux Return Yoke

The principal difficulty in large magnetic systems having an extensive flux return yoke is to characterize the magnetic flux distribution in the yoke steel blocks. Continuous measurements of the magnetic flux density in the return yoke are not possible and the usual practice uses software modelling of the magnetic system with special 3D computer programs. The flux return yoke of the Compact Muon Solenoid (CMS) magnet encloses a 3.8 T superconducting solenoid with a 6-m-diameter by 12.5-m-length free bore and consists of five dodecagonal three-layered barrel wheels around the coil and four endcap disks at each end. The yoke steel blocks serve as the absorber plates of the muon detection system. A TOSCA 3D model of the CMS magnet has been developed to describe the magnetic field outside of the solenoid volume, which was measured with a field-mapping machine. To verify the magnetic flux distribution calculated in the yoke steel blocks, direct measurements of the magnetic flux density with 22 flux loops installed in selected regions of the yoke were performed during the CMS magnet test in 2006 when four "fast" discharges of the CMS coil were triggered manually to test the magnet protection system. No fast discharge of the CMS magnet from its operational current of 18.2 kA, which corresponds to a central magnetic flux density of 3.8 T, has been performed that time. For the first time, in this paper we present measurements of the magnetic flux density in the steel blocks of the return yoke based on the several standard linear discharges of the CMS magnet from the operational magnet current of 18.2 kA. To provide these measurements, the voltages induced in the flux loops have been measured with six 16-bit DAQ modules and integrated offline over time. The results of the measurements during magnet linear ramps performed with a current rate as low as 1-1.5 A/s are presented and discussed.