Researcher profile

Vasiliki Stergiopoulou

Vasiliki Stergiopoulou contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

3D Image Super-Resolution by fluorophore fluctuations and MA-TIRF Microscopy reconstruction (3D-COL0RME)

We propose a 3D super-resolution approach to improve both lateral and axial spatial resolution in Total Internal Reflectance Fluorescence (TIRF) imaging applications. Our approach, called 3D-COL0RME (3D - Covariance-based $\ell_0$ super-Resolution Microscopy with intensity Estimation) improves both lateral and axial resolution by combining sparsity-based modelling for precise molecule localisation and intensity estimation in the lateral plane with a 3D reconstruction procedure in the axial one using Multi-Angle TIRF (MA-TIRF). Differently from state-of-the-art approaches, 3D-COL0RME does not require the use of special equipment as it can be used with standard fluorophores. We validate 3D-COL0RME on simulated MA-TIRF blinking-type data and on challenging real MA-TIRF acquisitions, showing significant resolution improvements.

preprint2022arXiv

COL0RME: COvariance-based $\ell_0$ super-Resolution Microscopy with intensity Estimation

Super-resolution light microscopy overcomes the physical barriers due to light diffraction, allowing for the observation of otherwise indistinguishable subcellular entities. However, the specific acquisition conditions required by state-of-the-art super-resolution methods to achieve adequate spatio-temporal resolution are often very challenging. Exploiting molecules fluctuations allows good spatio-temporal resolution live-cell imaging by means of common microscopes and conventional fluorescent dyes. In this work, we present the method COL0RME for COvariance-based $\ell_0$ super-Resolution Microscopy with intensity Estimation. It codifies the assumption of sparse distribution of the fluorescent molecules as well as the temporal and spatial independence between emitters via a non-convex optimization problem formulated in the covariance domain. In order to deal with real data, the proposed approach also estimates background and noise statistics. It also includes a final estimation step where intensity information is retrieved, which is valuable for biological interpretation and future applications to super-resolution imaging.

preprint2022arXiv

COL0RME: Super-resolution microscopy based on sparse blinking/fluctuating fluorophore localization and intensity estimation

To overcome the physical barriers caused by light diffraction, super-resolution techniques are often applied in fluorescence microscopy. State-of-the-art approaches require specific and often demanding acquisition conditions to achieve adequate levels of both spatial and temporal resolution. Analyzing the stochastic fluctuations of the fluorescent molecules provides a solution to the aforementioned limitations, as sufficiently high spatio-temporal resolution for live-cell imaging can be achieved by using common microscopes and conventional fluorescent dyes. Based on this idea, we present COL0RME, a method for COvariance-based $\ell_0$ super-Resolution Microscopy with intensity Estimation, which achieves good spatio-temporal resolution by solving a sparse optimization problem in the covariance domain and discuss automatic parameter selection strategies. The method is composed of two steps: the former where both the emitters' independence and the sparse distribution of the fluorescent molecules are exploited to provide an accurate localization; the latter where real intensity values are estimated given the computed support. The paper is furnished with several numerical results both on synthetic and real fluorescence microscopy images and several comparisons with state-of-the art approaches are provided. Our results show that COL0RME outperforms competing methods exploiting analogously temporal fluctuations; in particular, it achieves better localization, reduces background artifacts and avoids fine parameter tuning.