Researcher profile

V. Pereimak

V. Pereimak contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2021arXiv

Fluorescence of pyrene-doped polystyrene films from room temperature down to 4 K for wavelength-shifting applications

In liquid argon-based particle detectors, slow wavelength shifters (WLSs) could be used alongside the common, nanosecond scale, WLS tetraphenyl butadiene (TPB) for background mitigation purposes. At room temperature, pyrene has a moderate fluorescence light yield (LY) and a time constant of the order of hundreds of nanoseconds. In this work, four pyrene-doped polystyrene films with various purities and concentrations were characterized in terms of LY and decay time constants in a range of temperature between 4 K and 300 K under ultraviolet excitation. These films were found to have a LY between 35 and 50% of that of evaporated TPB. All light yields increase when cooling down, while the decays slow down. At room temperature, we observed that pyrene purity is strongly correlated with emission lifetime: highest obtainable purity samples were dominated by decays with emission time constants of $\sim$ 250-280 ns, and lower purity samples were dominated by an $\sim$ 80 ns component. One sample was investigated further to better understand the monomer and excimer emissions of pyrene. The excimer-over-monomer intensity ratio decreases when the temperature goes down, with the monomer emission dominating below $\sim$ 87 K.

preprint2021arXiv

Ultraviolet-induced fluorescence of poly(methyl methacrylate) compared to 1,1,4,4-tetraphenyl-1,3-butadiene down to 4 K

Several particle-physics experiments use poly(methyl methacrylate) (a.k.a. PMMA or acrylic) vessels to contain liquid scintillators. Superluminal charged particles emitted from radioactive impurities in or near the acrylic can emit Cherenkov radiation in the ultraviolet (UV) spectra range. If acrylic fluoresces in the visible range due to this UV light, it could be a source of background in experiments where the main signal is visible scintillation light, or UV scintillation light that is absorbed and re-emitted at visible wavelengths by a wavelength shifter. Some of these experiments operate at low temperature. The fluorescence of these materials could change with temperature so we have studied the fluorescence of the acrylic used in the DEAP-3600 experiment down to a temperature of 4 K, and compared it to the common wavelength shifter 1,1,4,4-tetraphenyl-1,3-butadiene (TPB). The light yield and wavelength spectra of these materials were characterized by exciting the sample with 285 nm UV light which acted as a proxy for Cherenkov light in the detector. Spectral measurements indicate at least part of the fluorescence of the acrylic is due to additives. Time-resolved measurements show the light yields of our acrylic sample, TPB sample, and the relative light between both samples, all increase when cooling down. At room temperature, the light yield of our acrylic sample relative to the TPB sample is 0.3 %, while it reaches 0.5 % at 4 K. The main fluorescence time constant of the acrylic is less than a few nanoseconds.