Source author record

V. Murugesan

V. Murugesan appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Ultra-sensitive Super-THz Microwave Kinetic Inductance Detectors for future space telescopes

Future actively cooled space-borne observatories for the far-infrared, loosely defined as a 1--10 THz band, can potentially reach a sensitivity limited only by background radiation from the Universe. This will result in an increase in observing speed of many orders of magnitude. A spectroscopic instrument on such an observatory requires large arrays of detectors with a sensitivity expressed as a noise equivalent power NEP = 3 $\times 10^{-20}$ $W\surd{Hz}$. We present the design, fabrication, and characterisation of microwave kinetic inductance detectors (MKIDs) for this frequency range reaching the required sensitivity. The devices are based on thin-film NbTiN resonators which use lens-antenna coupling to a submicron-width aluminium transmission line at the shorted end of the resonator where the radiation is absorbed. We optimised the MKID geometry for a low NEP by using a small aluminium volume of $\approx$ 1$μm^3$ and fabricating the aluminium section on a very thin (100 nm) SiN membrane. Both methods of optimisation also reduce the effect of excess noise by increasing the responsivity of the device, which is further increased by reducing the parasitic geometrical inductance of the resonator. We measure the sensitivity of eight MKIDs with respect to the power absorbed in the detector using a thermal calibration source filtered in a narrow band around 1.55 THz. We obtain a NEP$_{exp}(P_{abs})\:=\:3.1\pm0.9\times10^{-20}\:W\surd{Hz}$ at a modulation frequency of 200 Hz averaged over all measured MKIDs. The NEP is limited by quasiparticle trapping. The measured sensitivity is sufficient for spectroscopic observations from future, actively cooled space-based observatories. Moreover, the presented device design and assembly can be adapted for frequencies up to $\approx$ 10 THz and can be readily implemented in kilopixel arrays.

preprint2020arXiv

Suppression of radiation loss in high kinetic inductance superconducting co-planar waveguides

We present a novel lab-on-chip technique to measure the very low losses in superconducting transmission lines at (sub-) mm wavelengths. The chips consist of a 100 nm thick NbTiN Coplanar Waveguide (CPW) Fabry Perot (FP) resonator, coupled on one side to an antenna and on the other side to a Microwave Kinetic Inductance detector. Using a single frequency radiation source allows us to measure the frequency response of the FP around 350 GHz and deduce its losses. We show that the loss is dominated by radiation loss inside the CPW line that forms the FP and that it decreases with decreasing line width and increasing kinetic inductance as expected. The results can be quantitatively understood using SONNET simulations. The lowest loss is observed for a CPW with a total width of $6\ \mathrm{μm}$ and corresponds to a Q-factor of $\approx15,000$.

preprint2016arXiv

Calibration scheme for large Kinetic Inductance Detector Arrays based on Readout Frequency Response

Microwave kinetic inductance detector (MKID) provides a way to build large ground based sub-mm instruments such as NIKA and A-MKID. For such instruments, therefore, it is important to understand and characterize the response to ensure good linearity and calibration over wide dynamic range. We propose to use the MKID readout frequency response to determine the MKID responsivity to an input optical source power. A signal can be measured in a KID as a change in the phase of the readout signal with respect to the KID resonant circle. Fundamentally, this phase change is due to a shift in the KID resonance frequency, in turn due to a radiation induced change in the quasiparticle number in the superconducting resonator. We show that shift in resonant frequency can be determined from the phase shift by using KID phase versus frequency dependence using a previously measured resonant frequency. Working in this calculated resonant frequency, we gain near linearity and constant calibration to a constant optical signal applied in a wide range of operating points on the resonance and readout powers. This calibration method has three particular advantages: first, it is fast enough to be used to calibrate large arrays, with pixel counts in the thousand of pixels; second, it is based on data that are already necessary to determine KID positions; third, it can be done without applying any optical source in front of the array.