Source author record

V. Mikhaylov

V. Mikhaylov appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

Characterisation of SiPM radiation hardness for application in hadron calorimeters at FAIR, CERN and NICA

Silicon PhotoMultipliers (SiPM) are an excellent choice for the scintillator light readout at hadron calorimeters due to their insensitivity to magnetic fields, low operating voltages, low cost, compactness and mechanical endurance. They are already successfully utilized in Projectile Spectator Detector (PSD) of NA61 at CERN, and will be utilized soon in PSD of CBM at FAIR and Forward Hadron CALorimeters (FHCAL) of BM@N at NICA heavy-ion collision experiments. The main issue of SiPM application is their degradation due to high neutron fluence that can reach up to 2E11 neq/cm2 per year of the experiment operation. Multiple irradiation tests of SiPMs produced by Ketek, Zecotek, Hamamatsu and Sensl manufacturers were conducted at the cyclotron of NPI Rez with a broad neutron spectrum and total fluences in the wide range of 5E10 - 6E12 neq/cm2. Detailed characterisation of all SiPMs was performed based on dependencies of dark current on voltage, capacitance on voltage and frequency, and response to LED light on voltage. SiPM's breakdown voltage, quenching resistance, pixel capacitance, gain and signal to noise ratio were extracted from these measurements. Those parameters' dependence on neutron fluence and their variability are discussed. Performance of the PSD calorimeter module equipped with irradiated SiPMs in CERN during the beam scan with 2 - 80 GeV/c protons is briefly overviewed.

preprint2020arXiv

Two-Pion production in the second resonance region in $π^- p$ collisions with HADES

Pion induced reactions provide unique opportunities for an unambiguous description of baryonic resonances and their coupling channels by means of a partial wave analysis. Using the secondary pion beam at SIS18, the two pion production in the second resonance region has been investigated to unravel the role of the $N(1520) \frac{3}{2}^-$ resonance in the intermediate $ρ$ production. Results on exclusive channels with one pion ($π^{-}p$) and two pions ($π^{+}π^{-}n$, $π^{0}π^{-}p$) in the final state measured in the $π^{-}-p$ reaction at four different pion beam momenta (0.650, 0.685, 0.733, and 0.786 GeV/c) are presented. The excitation function of the different partial waves and $Δπ$, $Nσ$ and $Nρ$ isobar configurations is obtained, using the Bonn-Gatchina partial wave analysis. The $N(1520) \frac{3}{2}^-$ resonance is found to dominate the $Nρ$ final state with the branching ratio $BR=12.2 \pm 1.9\%$.

preprint2015arXiv

Investigation of avalanche photodiodes radiation hardness for baryonic matter studies

Modern avalanche photodiodes (APDs) with high gain are good device candidates for light readout from detectors applied in relativistic heavy ion collisions experiments. The results of the investigations of the APDs properties from Zecotek, Ketek and Hamamatsu manufacturers after irradiation using secondary neutrons from cyclotron facility U120M at NPI of ASCR in Řež are presented. The results of the investigations can be used for the design of the detectors for the experiments at NICA and FAIR.